Anne Sophie Polge
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anne Sophie Polge has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alexandre Delarue
Paediatric and Congenital Cardiology Unit, Lille University Hospital, Institut Coeur Poumon, Lille University, UFR3S, Rue Pr. Leclercq, 59000 Lille, France
1 shared publication - Ali Houeijeh
Institut CŒUR Poumon
1 shared publication - François Godart
Paediatric and Congenital Cardiology Department, Heart and Lung Institute, University Hospital of Lille , Lille 59000
1 shared publication - Jean Benoit Baudelet
Service de Cardiologie infantile et congénitale CHU de Lille Lille France
1 shared publication - Olivia Domanski
CHU Lille, Hôpital Cardiologique, Lille, France
1 shared publication - Said Bichali
Department of Pediatric Cardiology and Congenital Heart Disease, Institut Cœur Poumon, CHRU Lille, 59000 Lille, France
1 shared publication
Latest Publications
- Open Access
- 5 October 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (19) , 6370
Transcatheter Closure of Perimembranous Ventricular Septal Defects Including Multifenestrated and Gerbode-Type Defects Using the Lifetech Konar Device
(1) Transcatheter closure of perimembranous ventricular septal defects (PmVSD) is becoming more attractive and effective with the development of new occluders. The aim of this study was to report a single-center experience in PmVSD closure using the Lifetech Konar-multifunctional occluder (MFO). (2) From March 2019 to October 2022, 43 consecutive patients were enrolled in the study. Among them, 13 had multifenestrated PmVSD including 5 Gerbode-type defects. (3) There were 23 males/20 females, and the median age was 17 years (range 2–68 years). Trivial aortic regurgitation was noticed in 19 patients. Implantation was successful in all patients under general anesthesia. A retrograde approach was used in 35 patients (81%). The retrograde approach was associated with a lower radiation dose (p = 0.042) and shorter fluoroscopy time (p = 0.002) compared to the antegrade approach. Full occlusion was observed immediately in 12 patients (28%) and in 33 patients (77%) at a median follow-up of 11 months. There were no complications such as embolization, complete atrioventricular block, device dislocation, new onset above grade I, or progression of tricuspid or aortic valve regurgitation. Seven of the thirteen patients with a multifenestrated defect had no residual shunt. The persistent shunts were all trivial intra-prosthetic leaks. (4) MFO is effective and safe for PmVSD closure including multifenestrated/Gerbode-type defects with no complication. However, a longer follow-up remains warranted to establish the safety of this technique.
- 5 October 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (19) , 6370
Open AccessTranscatheter Closure of Perimembranous Ventricular Septal Defects Including Multifenestrated and Gerbode-Type Defects Using the Lifetech Konar Device
(1) Transcatheter closure of perimembranous ventricular septal defects (PmVSD) is becoming more attractive and effective with the development of new occluders. The aim of this study was to report a single-center experience in PmVSD closure using the Lifetech Konar-multifunctional occluder (MFO). (2) From March 2019 to October 2022, 43 consecutive patients were enrolled in the study. Among them, 13 had multifenestrated PmVSD including 5 Gerbode-type defects. (3) There were 23 males/20 females, and the median age was 17 years (range 2–68 years). Trivial aortic regurgitation was noticed in 19 patients. Implantation was successful in all patients under general anesthesia. A retrograde approach was used in 35 patients (81%). The retrograde approach was associated with a lower radiation dose (p = 0.042) and shorter fluoroscopy time (p = 0.002) compared to the antegrade approach. Full occlusion was observed immediately in 12 patients (28%) and in 33 patients (77%) at a median follow-up of 11 months. There were no complications such as embolization, complete atrioventricular block, device dislocation, new onset above grade I, or progression of tricuspid or aortic valve regurgitation. Seven of the thirteen patients with a multifenestrated defect had no residual shunt. The persistent shunts were all trivial intra-prosthetic leaks. (4) MFO is effective and safe for PmVSD closure including multifenestrated/Gerbode-type defects with no complication. However, a longer follow-up remains warranted to establish the safety of this technique.