R. R. Kharchilava
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
R. R. Kharchilava has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Alexandra A. Mishchenko
Academician I.P. Pavlov First St. Petersburg State Medical University
2 shared publications - Dmitry Gorelov
Academician I.P. Pavlov First Saint Petersburg State Medical University
2 shared publications - Sergeii B. Petrov
Academician I.P. Pavlov First Saint Petersburg State Medical University
2 shared publications - Vladislav P. Britov
Saint Petersburg State Technological Institute (Technical University)
2 shared publications - Aleksei G. Martov
Central Clinical Hospital of Civil Aviation”; Medical and Biological University of Innovation and Continuing Education — Burnazyan Federal Medical Biophysical Center of the FMBA of Russia; Medical Scientific and Educational Center — Lomonosov Moscow State University (Lomonosov University)
1 shared publication - Dmitry Dmitrievich Shkarupa
Saint Petersburg State University
1 shared publication
Latest Publications
- Open Access
- 25 March 2025
- Published by UroMedia LLC in Experimental and Сlinical Urology
- Vol. 18 (1)
New Prospects for Urolithiasis Metaphylaxis in Russia. Advisory board resolution (October 30, 2024).
Advisory board was held in Moscow оn October 30, 2024, dedicated to the problem of preventing relapses (metaphylaxis) of urolithiasis. The next questions were discussed during the meeting: the cost-effectiveness of urolithiasis metaphylaxis in the Russian Federation, what kind of patients and in what cases it is indicated, what parameters should be used to select a remedy for urolithiasis metaphylaxis. A discussion was held on the prospects for introducing metaphylaxis into urological practice in connection with the release of updated clinical guidelines for urolithiasis by the Ministry of Health of the Russian Federation, in particular, a new section on anti-relapse therapy for the disease. This section includes components of the Lit-Control® Litura® line of products that have a scientific basis and high potential in urolithiasis metaphylaxis. This line of products can be recommended for long-term use by patients with urolithiasis, from 3 months or more, with the selection of a product depending on the chemical composition of the stone and metabolic disorders, including urine acidity.
- 25 March 2025
- Published by UroMedia LLC in Experimental and Сlinical Urology
- Vol. 18 (1)
Open AccessNew Prospects for Urolithiasis Metaphylaxis in Russia. Advisory board resolution (October 30, 2024).
Advisory board was held in Moscow оn October 30, 2024, dedicated to the problem of preventing relapses (metaphylaxis) of urolithiasis. The next questions were discussed during the meeting: the cost-effectiveness of urolithiasis metaphylaxis in the Russian Federation, what kind of patients and in what cases it is indicated, what parameters should be used to select a remedy for urolithiasis metaphylaxis. A discussion was held on the prospects for introducing metaphylaxis into urological practice in connection with the release of updated clinical guidelines for urolithiasis by the Ministry of Health of the Russian Federation, in particular, a new section on anti-relapse therapy for the disease. This section includes components of the Lit-Control® Litura® line of products that have a scientific basis and high potential in urolithiasis metaphylaxis. This line of products can be recommended for long-term use by patients with urolithiasis, from 3 months or more, with the selection of a product depending on the chemical composition of the stone and metabolic disorders, including urine acidity.
- Open Access
- 7 July 2024
- Published by Rostov State Medical University in Urology Herald
- Vol. 12 (3) , 27-35
Ultrasound-guided renal cavity puncture simulators: comparative characterisation and validation
Introduction. Teaching the skill of renal cavity puncture remains a pressing issue for both resident trainees and practicing physicians. Because patient-based training is ethically questionable and can be unsafe in terms of complications, training models have been created to practice skills.Objective. To compare two non-biological simulators for renal cavity puncture under ultrasound guidance: “UROSON”, GEOTAR, Russia and the kidney phantom “SafeToAct”, Estonia.Materials & methods. The study involved 40 young doctors with no experience in kidney puncture. Group 1 (20 people) practised on the UROSON simulator (GEOTAR, Russia). Group 2 (20 people) trained on a kidney phantom (SafeToAct, Estonia). Both simulators were evaluated by doctors before and after practice, as well as in the long-term period for 3 and 6 months. The assessment was carried out using a Likert scale.Results. The UROSON was rated higher (p < 0.05) according to the results of the comparison of the parameters (colour and consistency, visualisation of the cavity and calyx on ultrasound). Renal cavity visualisation of the UROSON simulator was rated as "good" throughout the study. Visualisation deteriorated by 6.9% after six months of use. Meanwhile, the SafeToAct kidney phantom showed a 64% deterioration in visualisation after one month of use. The SafeToAct kidney phantom was not evaluated later point because it became unusable. Both simulators had "tracks" after punctures. The UROSON had 30% and the SafeToAct kidney phantom 100% (p < 0.0001).Conclusion. The UROSON simulator can be used for training, master classes and accreditation of specialists. This simulator can be used for a long time.
- 7 July 2024
- Published by Rostov State Medical University in Urology Herald
- Vol. 12 (3) , 27-35
Open AccessUltrasound-guided renal cavity puncture simulators: comparative characterisation and validation
Introduction. Teaching the skill of renal cavity puncture remains a pressing issue for both resident trainees and practicing physicians. Because patient-based training is ethically questionable and can be unsafe in terms of complications, training models have been created to practice skills.Objective. To compare two non-biological simulators for renal cavity puncture under ultrasound guidance: “UROSON”, GEOTAR, Russia and the kidney phantom “SafeToAct”, Estonia.Materials & methods. The study involved 40 young doctors with no experience in kidney puncture. Group 1 (20 people) practised on the UROSON simulator (GEOTAR, Russia). Group 2 (20 people) trained on a kidney phantom (SafeToAct, Estonia). Both simulators were evaluated by doctors before and after practice, as well as in the long-term period for 3 and 6 months. The assessment was carried out using a Likert scale.Results. The UROSON was rated higher (p < 0.05) according to the results of the comparison of the parameters (colour and consistency, visualisation of the cavity and calyx on ultrasound). Renal cavity visualisation of the UROSON simulator was rated as "good" throughout the study. Visualisation deteriorated by 6.9% after six months of use. Meanwhile, the SafeToAct kidney phantom showed a 64% deterioration in visualisation after one month of use. The SafeToAct kidney phantom was not evaluated later point because it became unusable. Both simulators had "tracks" after punctures. The UROSON had 30% and the SafeToAct kidney phantom 100% (p < 0.0001).Conclusion. The UROSON simulator can be used for training, master classes and accreditation of specialists. This simulator can be used for a long time.
- Open Access
- 4 October 2023
- Published by Rostov State Medical University in Urology Herald
- Vol. 11 (3) , 23-34
Comparative evaluation of simulators for practising fluoroscopy-guided renal pelvic puncture
Introduction. The skill of puncture of the kidney pelvicalyceal system is one of the basic urological skills, as it is used for various surgical interventions. There are different training models, from laboratory animals to virtual reality simulators.Objective. To evaluate a non-biological model of the pelvicalyceal system puncture simulator UroATOM (“Alfa-Rhythm”, Russian Federation) and to compare it with a virtual reality simulator PERC MentorTM (“Simbionix”, Beit Golan, Israel).Materials & methods. The results of fluoroscopic guided puncture training were analyzed among 50 physicians. The specialists were divided into two equal groups by experience: group 1 — beginners, group 2 — experienced urologists. In phase 1, both simulators were evaluated by the physicians using Likert questionnaires. In phase 2, the puncture results in beginners were evaluated before and after the UroATOM simulator practise.Results. Comparing the indices of both simulators showed that UroATOM was rated as more convenient to use (p = 0.0001) and cheaper (p < 0.0001). The analysis of the puncture performance by "beginners" before and after UroATOM training revealed a statistically significant improvement in the performance. The puncture time index improved by 79 seconds. The index of fluoroscopy duration decreased by 40.9 seconds. The number of puncture attempts decreased by 1.4 times. The amount of contrast decreased by 5.4 ml.Conclusions. The UroATOM simulator is effective for training young specialists in fluoroscopy-guided renal cavity puncture.
- 4 October 2023
- Published by Rostov State Medical University in Urology Herald
- Vol. 11 (3) , 23-34
Open AccessComparative evaluation of simulators for practising fluoroscopy-guided renal pelvic puncture
Introduction. The skill of puncture of the kidney pelvicalyceal system is one of the basic urological skills, as it is used for various surgical interventions. There are different training models, from laboratory animals to virtual reality simulators.Objective. To evaluate a non-biological model of the pelvicalyceal system puncture simulator UroATOM (“Alfa-Rhythm”, Russian Federation) and to compare it with a virtual reality simulator PERC MentorTM (“Simbionix”, Beit Golan, Israel).Materials & methods. The results of fluoroscopic guided puncture training were analyzed among 50 physicians. The specialists were divided into two equal groups by experience: group 1 — beginners, group 2 — experienced urologists. In phase 1, both simulators were evaluated by the physicians using Likert questionnaires. In phase 2, the puncture results in beginners were evaluated before and after the UroATOM simulator practise.Results. Comparing the indices of both simulators showed that UroATOM was rated as more convenient to use (p = 0.0001) and cheaper (p < 0.0001). The analysis of the puncture performance by "beginners" before and after UroATOM training revealed a statistically significant improvement in the performance. The puncture time index improved by 79 seconds. The index of fluoroscopy duration decreased by 40.9 seconds. The number of puncture attempts decreased by 1.4 times. The amount of contrast decreased by 5.4 ml.Conclusions. The UroATOM simulator is effective for training young specialists in fluoroscopy-guided renal cavity puncture.