Rijhi Dey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rijhi Dey has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Ujjwal Mondal
Instrumentation Engineering, Department of Applied Physics, University of Calcutta, India
6 shared publicationsRudra Sankar Dhar
Department of Electronics and Communication Engineering, National Institute of Technology Mizoram, India
4 shared publicationsAnirban Sengupta
Sikkim Manipal Institute of Technology, Sikkim Manipal University
2 shared publicationsNaiwrita Dey
RCCIIT
2 shared publications- Aniruddha Biswas
JIS College of Engineering
1 shared publication - Arindam Sarkar
Jadavpur University
1 shared publication
Latest Publications
- 1 April 2026
- Published by Springer Nature
- p. 378-387
Performance Evaluation of Classification Algorithms for the Prediction of Lung Cancer
- 1 April 2026
- Published by Springer Nature
- p. 378-387
Performance Evaluation of Classification Algorithms for the Prediction of Lung Cancer
- 20 November 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 113
DWT-based FDRC for continuous pace tracking of an LSTM-based predictive pacemaker
- 20 November 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 113
DWT-based FDRC for continuous pace tracking of an LSTM-based predictive pacemaker
- 30 September 2023
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 46 (7) , 1410-1417
Artificial neural network–based modelling of pacemaker and its pace tracking using discrete wavelet transform–based finite dimension repetitive controller
Efficient control of cardiac pacing is a very important aspect as it provides lifesaving regulated cardiac rhythm in this dynamic hostile environment. The foremost control objective is set to design a highly reliable and advanced control strategy to ensure the utmost accuracy in the control effort. A modified artificial neural network (ANN)–based modelling and pace tracking using finite dimension repetitive controller (FDRC) design based on internal model principle (IMP) has been presented here. This controller will not only provide accurate tracking but also minimize the control action time due to less amount of data handling through the deployment of discrete wavelet transform (DWT) in the loop of repetitive controller (RC). Finally, a case study has been propounded considering ANN model using available data sets and software to validate the control strategy and justify the control objective for optimizing the pace tracking in a pacemaker. Result of the experiment showed good accuracy as well as very low error in terms of mean-squared error (MSE), integral absolute error (IAE), integral time absolute error (ITAE) and integral time square error (ITSE). Along with that, it is observed that DWT not only benefits the handling of very less memory but also acts as an additional filter while reconstructing the signal, which serves as an added advantage of this model.
- 30 September 2023
- Published by SAGE Publications in Transactions of the Institute of Measurement and Control
- Vol. 46 (7) , 1410-1417
Artificial neural network–based modelling of pacemaker and its pace tracking using discrete wavelet transform–based finite dimension repetitive controller
Efficient control of cardiac pacing is a very important aspect as it provides lifesaving regulated cardiac rhythm in this dynamic hostile environment. The foremost control objective is set to design a highly reliable and advanced control strategy to ensure the utmost accuracy in the control effort. A modified artificial neural network (ANN)–based modelling and pace tracking using finite dimension repetitive controller (FDRC) design based on internal model principle (IMP) has been presented here. This controller will not only provide accurate tracking but also minimize the control action time due to less amount of data handling through the deployment of discrete wavelet transform (DWT) in the loop of repetitive controller (RC). Finally, a case study has been propounded considering ANN model using available data sets and software to validate the control strategy and justify the control objective for optimizing the pace tracking in a pacemaker. Result of the experiment showed good accuracy as well as very low error in terms of mean-squared error (MSE), integral absolute error (IAE), integral time absolute error (ITAE) and integral time square error (ITSE). Along with that, it is observed that DWT not only benefits the handling of very less memory but also acts as an additional filter while reconstructing the signal, which serves as an added advantage of this model.
- 30 August 2022
- Published by Springer Nature
- p. 511-518
Comparative Study on Tuning PID and FOPID Using Genetic Algorithm for Heart Rate Control of a Pacemaker
- 30 August 2022
- Published by Springer Nature
- p. 511-518
Comparative Study on Tuning PID and FOPID Using Genetic Algorithm for Heart Rate Control of a Pacemaker
- 30 August 2022
- Published by Springer Nature
- p. 529-534
Design and Comparison of RC, RC-PD and RC-PID Controller Architectures in a Servo-Motor System
- 30 August 2022
- Published by Springer Nature
- p. 529-534
Design and Comparison of RC, RC-PD and RC-PID Controller Architectures in a Servo-Motor System
- 7 December 2021
- Published by Springer Nature
- p. 365-371
Application of Internal Model Principle Based Plug-in Repetitive Controller in Artificial Cardiovascular System
- 7 December 2021
- Published by Springer Nature
- p. 365-371
Application of Internal Model Principle Based Plug-in Repetitive Controller in Artificial Cardiovascular System