Beatriz Esteban-Cartelle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Beatriz Esteban-Cartelle has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Dolores Remedios Serrano
Department of Pharmaceutics and Food Technology, School of Pharmacy, Complutense University of Madrid, 28040 Madrid, Spain
3 shared publications - Ana María Álvarez-Díaz
Ramón y Cajal University Hospital
2 shared publications - Brayan Javier Anaya
Pharmaceutics and Food Technology Department, Faculty of Pharmacy, Universidad Complutense de Madrid, Plaza Ramón y Cajal s/n, 28040 Madrid, Spain
2 shared publications - Jesús Fortún
Department of Infectious Diseases, Ramón y Cajal University Hospital, Madrid, Spain
2 shared publications - Akim Chayem
Pharmacy Department, University Hospital, Allée du Morvan, 54511 Vandœuvre-lès-Nancy, France
1 shared publication Ana Álvarez-Díaz
Pharmacy Department, Ramón y Cajal Hospital, IRYCIS , Madrid, Spain
1 shared publication
Latest Publications
- Open Access
- 23 January 2026
- Published by MDPI AG in Antibiotics
- Vol. 15 (2) , 114
CEFEPIME/ENMETAZOBACTAM: Physicochemical Stability of a Novel β-Lactam/β-Lactamase Inhibitor Combination in Syringes and Elastomeric Devices
Background: Cefepime/enmetazobactam (FEP/META) is a novel fixed-dose β-lactam/β-lactamase inhibitor combination. The objective was to study the physicochemical stability of the approved daily dose in polypropylene syringes and elastomeric devices over a 24 or 72 h period to understand the feasibility of using FEP/META in prolonged infusions and its use for outpatient parenteral antibiotic therapy (OPAT). Methods: Solutions of FEP/META were prepared in 0.9% NaCl or 5% dextrose (D5W) and stored in syringes (6 g/1.5 g/48 mL) or silicone and polyisoprene elastomeric devices (EDs) at 6 g/1.5 g/120 mL and 6 g/1.5 g/240 mL: syringes were tested at 22–25 °C over a 24 h period, polyisoprene EDs at 2–8 °C over 72 h period, and silicone and polyisoprene EDs at 32 °C over a 24 h period. The solution was considered stable if it retained more than 90% of its initial concentration (Ci), no pH variation (±1 unit), no significant visual change, and with compliant subvisual examination. Liquid Chromatography–Electrospray Ionization–Quadrupole Time-of-Flight–Mass Spectrometry was utilized to identify intermediate degradation products. Results: At the daily dose, FEP/META retained >90% of its Ci up to 12 h in 0.9% NaCl and 24 h in D5W when stored in syringes. In silicone ED, stability was enhanced up to 24 h in D5W at all concentrations. The solution was chemically stable for 24 h when stored in polyisoprene ED in 0.9% NaCl at 2–8 °C. Conclusions: FEP/META combination showed prolonged stability with physicochemical integrity up to 12–24 h in all containers and conditions. It appears to be stable for prolonged infusions and for OPAT.
- 23 January 2026
- Published by MDPI AG in Antibiotics
- Vol. 15 (2) , 114
Open AccessCEFEPIME/ENMETAZOBACTAM: Physicochemical Stability of a Novel β-Lactam/β-Lactamase Inhibitor Combination in Syringes and Elastomeric Devices
Background: Cefepime/enmetazobactam (FEP/META) is a novel fixed-dose β-lactam/β-lactamase inhibitor combination. The objective was to study the physicochemical stability of the approved daily dose in polypropylene syringes and elastomeric devices over a 24 or 72 h period to understand the feasibility of using FEP/META in prolonged infusions and its use for outpatient parenteral antibiotic therapy (OPAT). Methods: Solutions of FEP/META were prepared in 0.9% NaCl or 5% dextrose (D5W) and stored in syringes (6 g/1.5 g/48 mL) or silicone and polyisoprene elastomeric devices (EDs) at 6 g/1.5 g/120 mL and 6 g/1.5 g/240 mL: syringes were tested at 22–25 °C over a 24 h period, polyisoprene EDs at 2–8 °C over 72 h period, and silicone and polyisoprene EDs at 32 °C over a 24 h period. The solution was considered stable if it retained more than 90% of its initial concentration (Ci), no pH variation (±1 unit), no significant visual change, and with compliant subvisual examination. Liquid Chromatography–Electrospray Ionization–Quadrupole Time-of-Flight–Mass Spectrometry was utilized to identify intermediate degradation products. Results: At the daily dose, FEP/META retained >90% of its Ci up to 12 h in 0.9% NaCl and 24 h in D5W when stored in syringes. In silicone ED, stability was enhanced up to 24 h in D5W at all concentrations. The solution was chemically stable for 24 h when stored in polyisoprene ED in 0.9% NaCl at 2–8 °C. Conclusions: FEP/META combination showed prolonged stability with physicochemical integrity up to 12–24 h in all containers and conditions. It appears to be stable for prolonged infusions and for OPAT.
- Open Access
- 2 July 2025
- Published by Springer Nature in Infectious Diseases and Therapy
- Vol. 14 (8) , 1685-1696
Stability of Ceftobiprole Medocaril in Portable Elastomeric Infusion Devices
Introduction Ceftobiprole medocaril is a new fifth-generation cephalosporin commercially available as a prodrug. Since it is newly introduced in therapy, there is limited data on its physicochemical stability for outpatient parenteral antimicrobial therapy (OPAT). This work aimed to demonstrate the suitability of ceftobiprole medocaril in OPAT, determining the physicochemical stability within portable elastomeric infusion devices (Accufuser C0100L 10 mL/h 300 mL). Methods Physicochemical stability was evaluated in 6.25 mg/mL solutions in sodium chloride 0.9% and dextrose 5% at three temperatures (2–8 °C, 25 °C, and 32 °C) using a previously validated liquid chromatography triple quadrupole mass spectrometry (LC-QQQ-MS) method. Drug adsorption onto device walls was also determined at the end of the study. Results Ceftobiprole medocaril remained above 95% of the initial concentration in sodium chloride 0.9% for up to 24 h at both refrigerated (2–8 °C) and ambient conditions (25 °C). Stability was reduced in dextrose 5% solutions. While pH increased slightly over time, it remained within acceptable limits for intravenous administration, and no particle formation was detected. Drug adsorption to the elastomeric device was negligible (< 0.1%). Conclusion Ceftobiprole medocaril is suitable for administration in OPAT at 6.25 mg/mL in sodium chloride 0.9% over 24 h at 25 °C using Accufuser® portable elastomeric infusion devices. These findings support the development of practical administration protocols for ceftobiprole medocaril in home-based antimicrobial therapy. Plain Language Summary Ceftobiprole medocaril is a new antibiotic used to treat serious infections. Because it was recently introduced, there is limited information about its stability when used for outpatient parenteral antimicrobial therapy (OPAT), a treatment that allows patients to receive intravenous antibiotics at home using portable elastomeric infusion devices. This study examined how stable ceftobiprole medocaril remains when stored and administered in portable elastomeric infusion devices. The antibiotic was diluted in two commonly used fluids (saline and dextrose) and kept at different temperatures: refrigerated (2–8 °C), room temperature (25 °C), and body temperature (32 °C). Researchers measured how much of the drug remained active over 24 hours and whether it adhered to the inside of the device. The results showed that ceftobiprole medocaril in saline solution (sodium chloride 0.9%) remained stable for 24 hours at room temperature and when refrigerated, keeping over 95% of its original amount. In dextrose, the drug was less stable. The pH changed slightly, but no harmful particles formed, and less than 0.1% of the drug stuck to the infusion device, confirming that the device is suitable for this use. On the basis of these findings, ceftobiprole medocaril can be safely administered in saline solution over 24 hours at room temperature using portable infusion devices. This helps support safe and effective use of the antibiotic in OPAT settings.
- 2 July 2025
- Published by Springer Nature in Infectious Diseases and Therapy
- Vol. 14 (8) , 1685-1696
Open AccessStability of Ceftobiprole Medocaril in Portable Elastomeric Infusion Devices
Introduction Ceftobiprole medocaril is a new fifth-generation cephalosporin commercially available as a prodrug. Since it is newly introduced in therapy, there is limited data on its physicochemical stability for outpatient parenteral antimicrobial therapy (OPAT). This work aimed to demonstrate the suitability of ceftobiprole medocaril in OPAT, determining the physicochemical stability within portable elastomeric infusion devices (Accufuser C0100L 10 mL/h 300 mL). Methods Physicochemical stability was evaluated in 6.25 mg/mL solutions in sodium chloride 0.9% and dextrose 5% at three temperatures (2–8 °C, 25 °C, and 32 °C) using a previously validated liquid chromatography triple quadrupole mass spectrometry (LC-QQQ-MS) method. Drug adsorption onto device walls was also determined at the end of the study. Results Ceftobiprole medocaril remained above 95% of the initial concentration in sodium chloride 0.9% for up to 24 h at both refrigerated (2–8 °C) and ambient conditions (25 °C). Stability was reduced in dextrose 5% solutions. While pH increased slightly over time, it remained within acceptable limits for intravenous administration, and no particle formation was detected. Drug adsorption to the elastomeric device was negligible (< 0.1%). Conclusion Ceftobiprole medocaril is suitable for administration in OPAT at 6.25 mg/mL in sodium chloride 0.9% over 24 h at 25 °C using Accufuser® portable elastomeric infusion devices. These findings support the development of practical administration protocols for ceftobiprole medocaril in home-based antimicrobial therapy. Plain Language Summary Ceftobiprole medocaril is a new antibiotic used to treat serious infections. Because it was recently introduced, there is limited information about its stability when used for outpatient parenteral antimicrobial therapy (OPAT), a treatment that allows patients to receive intravenous antibiotics at home using portable elastomeric infusion devices. This study examined how stable ceftobiprole medocaril remains when stored and administered in portable elastomeric infusion devices. The antibiotic was diluted in two commonly used fluids (saline and dextrose) and kept at different temperatures: refrigerated (2–8 °C), room temperature (25 °C), and body temperature (32 °C). Researchers measured how much of the drug remained active over 24 hours and whether it adhered to the inside of the device. The results showed that ceftobiprole medocaril in saline solution (sodium chloride 0.9%) remained stable for 24 hours at room temperature and when refrigerated, keeping over 95% of its original amount. In dextrose, the drug was less stable. The pH changed slightly, but no harmful particles formed, and less than 0.1% of the drug stuck to the infusion device, confirming that the device is suitable for this use. On the basis of these findings, ceftobiprole medocaril can be safely administered in saline solution over 24 hours at room temperature using portable infusion devices. This helps support safe and effective use of the antibiotic in OPAT settings.
- Open Access
- 11 January 2024
- Published by American Society for Microbiology in Microbiology Spectrum
- Vol. 12 (1) , e0206423
Stability of meropenem in portable elastomeric infusion devices: which protocol should be implemented in clinical practice?
Meropenem has an excellent activity against gram-positive and gram-negative bacteria, including multi-resistant microorganisms. Even though meropenem is a great candidate for outpatient parenteral antimicrobial therapy (OPAT), its physicochemical stability is a major challenge. This work aimed to demonstrate the suitability of including meropenem in OPAT by elucidating its physicochemical stability in a range of commonly prescribed concentrations within portable elastomeric infusion devices. Physical and chemical stability were evaluated at two concentrations commonly used in clinical practice (2 mg/mL and 25 mg/mL), and three temperatures (2–8°C, 25°C, and 32°C) using Accufuser portable elastomeric infusion devices. Drug adsorption onto portable elastomeric infusion devices was also determined at the end of the experiment. Meropenem stability significantly decreased at higher temperatures and when higher drug solution concentrations were used. Meropenem solutions at 2 mg/mL kept the drug content above 95% over 24 h at 2–8°C, but just for 8 h at 25°C. Nevertheless, solutions containing 25 mg/mL of meropenem showed a dramatic decrease in chemical stability after 8 h 2–8°C and just after 4 h at 25°C or 32°C. However, physical stability was kept favorable during this period. The drug adsorption on the material of the elastomeric infusion device was below 1%, indicating the suitability of the chosen device. We propose several administration protocols for meropenem in portable elastomeric infusion devices in clinical practice, according to the results obtained in our study. The results obtained in this study open up a possibility of administering meropenem in an OPAT setting despite its short stability. IMPORTANCE: Although outpatient parenteral antibiotic therapy can be a good approach to treating infections, a lack of data regarding antibiotic stability in portable elastomeric infusion devices restricts its safe and effective use. Actually, meropenem is used for prolonged periods above 24 h, and it is not physicochemically stable, which can compromise efficacy and toxicity. This work is of high importance to show the clinicians the real shelf life of meropenem when administered in portable elastomeric infusion devices. We propose several administration protocols for meropenem in portable elastomeric infusion devices in clinical practice, according to the stability drug results obtained in our study.
- 11 January 2024
- Published by American Society for Microbiology in Microbiology Spectrum
- Vol. 12 (1) , e0206423
Open AccessStability of meropenem in portable elastomeric infusion devices: which protocol should be implemented in clinical practice?
Meropenem has an excellent activity against gram-positive and gram-negative bacteria, including multi-resistant microorganisms. Even though meropenem is a great candidate for outpatient parenteral antimicrobial therapy (OPAT), its physicochemical stability is a major challenge. This work aimed to demonstrate the suitability of including meropenem in OPAT by elucidating its physicochemical stability in a range of commonly prescribed concentrations within portable elastomeric infusion devices. Physical and chemical stability were evaluated at two concentrations commonly used in clinical practice (2 mg/mL and 25 mg/mL), and three temperatures (2–8°C, 25°C, and 32°C) using Accufuser portable elastomeric infusion devices. Drug adsorption onto portable elastomeric infusion devices was also determined at the end of the experiment. Meropenem stability significantly decreased at higher temperatures and when higher drug solution concentrations were used. Meropenem solutions at 2 mg/mL kept the drug content above 95% over 24 h at 2–8°C, but just for 8 h at 25°C. Nevertheless, solutions containing 25 mg/mL of meropenem showed a dramatic decrease in chemical stability after 8 h 2–8°C and just after 4 h at 25°C or 32°C. However, physical stability was kept favorable during this period. The drug adsorption on the material of the elastomeric infusion device was below 1%, indicating the suitability of the chosen device. We propose several administration protocols for meropenem in portable elastomeric infusion devices in clinical practice, according to the results obtained in our study. The results obtained in this study open up a possibility of administering meropenem in an OPAT setting despite its short stability. IMPORTANCE: Although outpatient parenteral antibiotic therapy can be a good approach to treating infections, a lack of data regarding antibiotic stability in portable elastomeric infusion devices restricts its safe and effective use. Actually, meropenem is used for prolonged periods above 24 h, and it is not physicochemically stable, which can compromise efficacy and toxicity. This work is of high importance to show the clinicians the real shelf life of meropenem when administered in portable elastomeric infusion devices. We propose several administration protocols for meropenem in portable elastomeric infusion devices in clinical practice, according to the stability drug results obtained in our study.
- Open Access
- 19 June 2023
- Vol. 97
Trastornos en la calidad del sueño asociados a los inhibidores de la integrasa en el tratamiento del VIH
Los inhibidores de la integrasa se han posicionado recientemente en todas las Guías Clínicas de VIH como tratamiento antirretroviral de primera línea para el VIH. Sin embargo, dos de estos fármacos se han asociado también a efectos adversos a nivel del sistema nervioso central, concretamente con alteraciones del sueño. El objetivo del trabajo fue analizar la influencia de bictegravir y dolutegravir en la calidad del sueño en personas que viven con VIH (PVIH). Se realizó un estudio observacional y transversal entre los meses de diciembre de 2020 y enero de 2021 en las PVIH de las consultas de atención farmacéutica del hospital. Se recogieron variables demográficas y de adherencia. La calidad del sueño se midió mediante el Cuestionario de Pittsburgh o PSQI. Las PVIH se clasificaron en 2 grupos: el grupo estudio, constituido por participantes con bictegravir o dolutegravir en su tratamiento, y el grupo control, integrado por el resto de PVIH. Se analizó la influencia de las variables recogidas sobre el resultado del PSQI mediante la prueba de chi cuadrado/odds ratio para variables categóricas y el de t de Student o U de Mann Whitney para variables continuas. Se incluyeron 119 PVIH, de las cuales un 64% en el grupo estudio y un 67% en el grupo control sufrían trastornos del sueño según el PSQI (p=0,788). Tampoco hubo diferencias estadísticamente significativas cuando se compararon los diferentes componentes del sueño entre los dos grupos. Un elevado porcentaje de PVIH, independientemente de si el TAR incluye bictegravir o dolutegravir, tienen problemas relacionados con la calidad del sueño. No se encuentra correlación entre la calidad del sueño y el tratamiento con bictegravir o dolutegravir comparado con el resto de tratamientos.
- 19 June 2023
- Vol. 97
Open AccessTrastornos en la calidad del sueño asociados a los inhibidores de la integrasa en el tratamiento del VIH
Los inhibidores de la integrasa se han posicionado recientemente en todas las Guías Clínicas de VIH como tratamiento antirretroviral de primera línea para el VIH. Sin embargo, dos de estos fármacos se han asociado también a efectos adversos a nivel del sistema nervioso central, concretamente con alteraciones del sueño. El objetivo del trabajo fue analizar la influencia de bictegravir y dolutegravir en la calidad del sueño en personas que viven con VIH (PVIH). Se realizó un estudio observacional y transversal entre los meses de diciembre de 2020 y enero de 2021 en las PVIH de las consultas de atención farmacéutica del hospital. Se recogieron variables demográficas y de adherencia. La calidad del sueño se midió mediante el Cuestionario de Pittsburgh o PSQI. Las PVIH se clasificaron en 2 grupos: el grupo estudio, constituido por participantes con bictegravir o dolutegravir en su tratamiento, y el grupo control, integrado por el resto de PVIH. Se analizó la influencia de las variables recogidas sobre el resultado del PSQI mediante la prueba de chi cuadrado/odds ratio para variables categóricas y el de t de Student o U de Mann Whitney para variables continuas. Se incluyeron 119 PVIH, de las cuales un 64% en el grupo estudio y un 67% en el grupo control sufrían trastornos del sueño según el PSQI (p=0,788). Tampoco hubo diferencias estadísticamente significativas cuando se compararon los diferentes componentes del sueño entre los dos grupos. Un elevado porcentaje de PVIH, independientemente de si el TAR incluye bictegravir o dolutegravir, tienen problemas relacionados con la calidad del sueño. No se encuentra correlación entre la calidad del sueño y el tratamiento con bictegravir o dolutegravir comparado con el resto de tratamientos.