Jiaqi Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiaqi Yang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Yihao Zheng
Mechanical and Materials Engineering, Biomedical Engineering, Robotics Engineering Worcester Polytechnic Institute Worcester Massachusetts USA
3 shared publications - Yang Liu
Global Institute of Future Technology, Shanghai Jiao Tong University, Shanghai, China
2 shared publications Bin Shen
Yangtze Delta Region Institute of Tsinghua University, Zhejiang, Jiaxing 314000, China
1 shared publication- Chenguang Li
Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Disease, Shanghai, China; National Clinical Research Center for Interventional Medicine, Shanghai, China; State Key Laboratory of Cardiovascular Disease, Zhongshan Hospital, Fudan University, Shanghai, China; NHC Key Laboratory of Ischemia Heart Disease, Shanghai, China; Key Laboratory of Viral Heart Disease, Chinese Academy of Medical Science, Shanghai, China
1 shared publication - Junbo Ge
Department of Cardiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases
1 shared publication - Katerina Angjeli
Department of Electrical and Computer Engineering, Worcester Polytechnic Institute, 100 Institute Road, Worcester, MA 01609-2280
1 shared publication
Latest Publications
- 26 August 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 146 (1) , 104424
Free-hand 3D ultrasound imaging for vascular access
Vascular access is required to draw the patient's blood into the dialysis machine and return the filtered blood to the patient during hemodialysis to treat end-stage renal disease. The most reliable vascular access is the arteriovenous fistula (AVF), which unfortunately may develop significant stenosis or obstruction as a major complication. To evaluate the AVF geometry for potential pathological features, this study aims to develop and validate a free-hand 3D ultrasound imaging system using conventional 2D ultrasound scanning with scanner motion data from an electromagnetic (EMT) sensor to spatially register the 2D image planes into a 3D image reconstruction. To temporally synchronize the 2D ultrasound images with the EMT motion data, we developed a scanning protocol that would be practical for clinical settings to simultaneously generate data features in both ultrasound scan data and EMT tracking data. The accuracy and reliability of free-hand 3D ultrasound imaging were assessed using a wire phantom and an AVF ultrasound phantom. The results show that the average normalized root mean square errors of the 3D reconstructed models compared to the wire phantom and the AVF phantom are 0.497 ± 0.144 % and 0.571 ± 0.127 %, respectively, which indicates a high degree of accuracy and consistency. This study demonstrated the efficacy and potential clinical feasibility of using a 2D ultrasound scanner and EMT sensing for free-hand 3D ultrasound imaging of AVF for vascular access monitoring.
- 26 August 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 146 (1) , 104424
Free-hand 3D ultrasound imaging for vascular access
Vascular access is required to draw the patient's blood into the dialysis machine and return the filtered blood to the patient during hemodialysis to treat end-stage renal disease. The most reliable vascular access is the arteriovenous fistula (AVF), which unfortunately may develop significant stenosis or obstruction as a major complication. To evaluate the AVF geometry for potential pathological features, this study aims to develop and validate a free-hand 3D ultrasound imaging system using conventional 2D ultrasound scanning with scanner motion data from an electromagnetic (EMT) sensor to spatially register the 2D image planes into a 3D image reconstruction. To temporally synchronize the 2D ultrasound images with the EMT motion data, we developed a scanning protocol that would be practical for clinical settings to simultaneously generate data features in both ultrasound scan data and EMT tracking data. The accuracy and reliability of free-hand 3D ultrasound imaging were assessed using a wire phantom and an AVF ultrasound phantom. The results show that the average normalized root mean square errors of the 3D reconstructed models compared to the wire phantom and the AVF phantom are 0.497 ± 0.144 % and 0.571 ± 0.127 %, respectively, which indicates a high degree of accuracy and consistency. This study demonstrated the efficacy and potential clinical feasibility of using a 2D ultrasound scanner and EMT sensing for free-hand 3D ultrasound imaging of AVF for vascular access monitoring.
- 6 February 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 142 (1) , 104374
A coronary atherectomy system with a novel burr design for two-phase operation
A coronary atherectomy system (CAS) was developed with a novel burr designed for a two-phase atherectomy procedure: low-speed drilling for lesion crossing and high-speed orbiting to achieve luminal gain, to removal the stenosis in artery. To investigate the CAS mechanism and validate its efficacy and safety. Engineering bench-top testings were conducted to evaluate the burr crossing time, luminal gain, debris size, temperature rise, and grinding force together with in-vivo and ex-vivo swine studies. The bench-top engineering testing results showed that the CAS can expand the calcified lumen diameter from 0.4 to 1.7 mm and the debris size, temperature rise, and grinding force were relatively low and safe. In the in-vivo swine study, the media and internal elastic membrane remained intact. The intima of the artery was removed at the 0-day follow-up and re-growthed at the 30-day follow-up. No abnormal phenomenon in the digital subtraction angiography, blood testing, ECG, and anatomy analysis were found. The ex-vivo study, by inserting a plaque surragate (graphite) into the coronary artery, showed similar efficacy in luminal gain and safety. This study demonstrated the efficacy and safety of CAS device with the novel two-phase burr design.
- 6 February 2025
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 142 (1) , 104374
A coronary atherectomy system with a novel burr design for two-phase operation
A coronary atherectomy system (CAS) was developed with a novel burr designed for a two-phase atherectomy procedure: low-speed drilling for lesion crossing and high-speed orbiting to achieve luminal gain, to removal the stenosis in artery. To investigate the CAS mechanism and validate its efficacy and safety. Engineering bench-top testings were conducted to evaluate the burr crossing time, luminal gain, debris size, temperature rise, and grinding force together with in-vivo and ex-vivo swine studies. The bench-top engineering testing results showed that the CAS can expand the calcified lumen diameter from 0.4 to 1.7 mm and the debris size, temperature rise, and grinding force were relatively low and safe. In the in-vivo swine study, the media and internal elastic membrane remained intact. The intima of the artery was removed at the 0-day follow-up and re-growthed at the 30-day follow-up. No abnormal phenomenon in the digital subtraction angiography, blood testing, ECG, and anatomy analysis were found. The ex-vivo study, by inserting a plaque surragate (graphite) into the coronary artery, showed similar efficacy in luminal gain and safety. This study demonstrated the efficacy and safety of CAS device with the novel two-phase burr design.
- 26 October 2023
- Published by ASME International in Journal of Medical Devices
- Vol. 17 (4) , 1-23
Experimental Investigation of the Calcified Plaque Material Removal Rate in Coronary Rotational Atherectomy
Rotational atherectomy (RA) is a minimally invasive procedure to remove the calcified atherosclerotic plaque from arteries to restore blood flow. It uses a high-speed, metal-bonded diamond abrasive grinding wheel to pulverize the calcified plaque into absorbable debris via a catheter through the artery. Although RA has been clinically used for over two decades, procedural complications persist and there remains a lack of consensus on the optimal device parameters. This study aims to investigate RA material removal rate (MRR) with respect to grinding wheel sizes and rotational speeds based on a tissue-mimicking phantom. Three grinding wheel sizes, 1.25, 1.5, and 1.75 mm in diameter, and three rotational speeds, 120,000, 150,000, and 180,000 rpm, were investigated. The RA MRR was presented as the luminal area gain and measured by microscopy and image processing. The results show the increase of the grinding wheel size or rotational speed leads to a higher MRR and luminal gain in RA. With a 1.75 mm diameter grinding wheel rotating at 180,000 rpm in a 2 mm initial diameter lumen, the max MRR and the luminal gain are 2.49 mm2/(three passes) and 5.09 mm2, respectively. The MRR decreases as the number of grinding passes increases during RA with the same grinding wheel rotating at a constant speed. This study provides a thorough understanding of the wheel size and speed effects on RA MRR for improvements in RA devices and clinical operational guidelines.
- 26 October 2023
- Published by ASME International in Journal of Medical Devices
- Vol. 17 (4) , 1-23
Experimental Investigation of the Calcified Plaque Material Removal Rate in Coronary Rotational Atherectomy
Rotational atherectomy (RA) is a minimally invasive procedure to remove the calcified atherosclerotic plaque from arteries to restore blood flow. It uses a high-speed, metal-bonded diamond abrasive grinding wheel to pulverize the calcified plaque into absorbable debris via a catheter through the artery. Although RA has been clinically used for over two decades, procedural complications persist and there remains a lack of consensus on the optimal device parameters. This study aims to investigate RA material removal rate (MRR) with respect to grinding wheel sizes and rotational speeds based on a tissue-mimicking phantom. Three grinding wheel sizes, 1.25, 1.5, and 1.75 mm in diameter, and three rotational speeds, 120,000, 150,000, and 180,000 rpm, were investigated. The RA MRR was presented as the luminal area gain and measured by microscopy and image processing. The results show the increase of the grinding wheel size or rotational speed leads to a higher MRR and luminal gain in RA. With a 1.75 mm diameter grinding wheel rotating at 180,000 rpm in a 2 mm initial diameter lumen, the max MRR and the luminal gain are 2.49 mm2/(three passes) and 5.09 mm2, respectively. The MRR decreases as the number of grinding passes increases during RA with the same grinding wheel rotating at a constant speed. This study provides a thorough understanding of the wheel size and speed effects on RA MRR for improvements in RA devices and clinical operational guidelines.