Funda Karaduman Yalçin
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Funda Karaduman Yalçin has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Kucuk
Harran University
1 shared publication - Habibe Hezer
Department of Chest Diseases, Ankara Bilkent City Hospital, 06800 Ankara, Türkiye
1 shared publication Hasan Husnu Yuce
Harran University
1 shared publication- Hatice Canan Hasanoğlu
Department of Pulmonary Diseases, Ankara Yıldırım Beyazıt University Faculty of Medicine, Ankara, Türkiye
1 shared publication - Hatice Kilic
Ankara Yıldırım Beyazıt University, School of Medicine, Department of Pulmonary Diseases. Ankara, Türkiye
1 shared publication - Nurefsan Boyaci
Harran University School of Medicine, Department of Radiology, Sanliurfa, Turkey
1 shared publication
Latest Publications
- Open Access
- 30 June 2023
- Published by Kocaeli University in Acta Medica Nicomedia
- Vol. 6 (2) , 179-183
Evaluation of Upper Extremity Venous Thrombosis with Doppler Ultrasonography in Peripheral Venous Line Applied Patients
Objectives: Peripherally inserted venous lines (PVL) may increase the risk of venous thrombosis due to vessel wall disarrangement. Aim of this study is to identify the cases of upper extremity venous thrombosis (UEVT) related to PVL since most of the PVLs applied to upper extremities. Methods: Sixty-nine hospitalized patients with previous or present PVL insertions were included in this prospective study. Upper extremity Doppler compression ultrasonography (USG) examination were performed to on all patients. The cases with detected UEVTs were evaluated as group 1 and the remaining cases were evaluated as group 2. Demographic parameters, PVL applications, intravenous treatments were compared between the groups. Results: UEVT was diagnosed by Doppler USG in 26 (37.7%) patients out of 69 patients. Lower extremity thrombosis was found in 10 (14.49%) patients. UEVT was observed in cephalic vein in 14 (53.8%) and in basilic vein in four (15.4%) out of 26 (37.7%) patients. Axillary and brachial deep UEVT was located in two (2.9%) cases. Superficial UEVT was found in 24 (34.8%) cases. Ceftriaxone, cefoperazone/sulbactam and esomeprazole were the mostly associated treatments with UEVT. UEVT was detected in five patients with PVL that were inserted only for drawing blood. Conclusion: PVL is a risk factor for UEVT since almost 1/3 of the patients revealed UEVT. When PVL is no longer needed or the need for intravenous therapy decreases, oral therapy should be planned and PVL should be removed. Removal of PVL appears to be necessary to avoid UEVT.
- 30 June 2023
- Published by Kocaeli University in Acta Medica Nicomedia
- Vol. 6 (2) , 179-183
Open AccessEvaluation of Upper Extremity Venous Thrombosis with Doppler Ultrasonography in Peripheral Venous Line Applied Patients
Objectives: Peripherally inserted venous lines (PVL) may increase the risk of venous thrombosis due to vessel wall disarrangement. Aim of this study is to identify the cases of upper extremity venous thrombosis (UEVT) related to PVL since most of the PVLs applied to upper extremities. Methods: Sixty-nine hospitalized patients with previous or present PVL insertions were included in this prospective study. Upper extremity Doppler compression ultrasonography (USG) examination were performed to on all patients. The cases with detected UEVTs were evaluated as group 1 and the remaining cases were evaluated as group 2. Demographic parameters, PVL applications, intravenous treatments were compared between the groups. Results: UEVT was diagnosed by Doppler USG in 26 (37.7%) patients out of 69 patients. Lower extremity thrombosis was found in 10 (14.49%) patients. UEVT was observed in cephalic vein in 14 (53.8%) and in basilic vein in four (15.4%) out of 26 (37.7%) patients. Axillary and brachial deep UEVT was located in two (2.9%) cases. Superficial UEVT was found in 24 (34.8%) cases. Ceftriaxone, cefoperazone/sulbactam and esomeprazole were the mostly associated treatments with UEVT. UEVT was detected in five patients with PVL that were inserted only for drawing blood. Conclusion: PVL is a risk factor for UEVT since almost 1/3 of the patients revealed UEVT. When PVL is no longer needed or the need for intravenous therapy decreases, oral therapy should be planned and PVL should be removed. Removal of PVL appears to be necessary to avoid UEVT.
- 11 January 2014
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 28 (6) , 567-572
Forty-five degree wrist angulation is optimal for ultrasound guided long axis radial artery cannulation in patients over 60 years old: a randomized study
Arterial cannulation is a common anaesthetic procedure that might be challenging and time-consuming in elderly patients. To establish an appropriate wrist joint position for arterial cannulation is crucial for ultrasound (US)-guided cannulation success. This study aimed to find out the optimal wrist joint angle for long axis in-plane (LA-IP) US-guided approach in radial artery cannulation in elderly patients. One hundred patients over 60 years old, who were assumed to require an arterial catheter for continuous blood pressure monitoring or frequent blood gas analysis in the intensive care unit or in the operating room were included in this prospective randomized study. Patients were randomized to five groups according to the wrist positions (0°, 15°, 30° 45° and 60° groups) for LA-IP approach for radial artery cannulation. Cannulation time (s), number of attempts, total success rate (%), first attempt success rate were recorded in all patients. Mean radial artery height was increased in 45° group compared to other groups (p < 0.05). Distance between skin and radial artery in 45° and 60° groups were statistically significantly decreased compared to 0° group (p < 0.05 for all comparisons). Mean cannulation time of 45° group was statistically decreased compared to other groups (p < 0.05). Number of attempts and total success rate were similar among groups, whereas first attempt success rate was significantly increased in 45° group compared to other groups (p < 0.05). Mean arterial height of the first attempt successful group was statistically increased compared to the first attempt failed group (p < 0.001) and mean cannulation time and mean number of attempts were also negatively correlated with arterial height (p < 0.001; for all comparisons). The 45° wrist angle increment might be advantageous in US-guided LA-IP radial artery cannulation in elderly patients in view of cannulation time and first attempt success rate.
- 11 January 2014
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 28 (6) , 567-572
Forty-five degree wrist angulation is optimal for ultrasound guided long axis radial artery cannulation in patients over 60 years old: a randomized study
Arterial cannulation is a common anaesthetic procedure that might be challenging and time-consuming in elderly patients. To establish an appropriate wrist joint position for arterial cannulation is crucial for ultrasound (US)-guided cannulation success. This study aimed to find out the optimal wrist joint angle for long axis in-plane (LA-IP) US-guided approach in radial artery cannulation in elderly patients. One hundred patients over 60 years old, who were assumed to require an arterial catheter for continuous blood pressure monitoring or frequent blood gas analysis in the intensive care unit or in the operating room were included in this prospective randomized study. Patients were randomized to five groups according to the wrist positions (0°, 15°, 30° 45° and 60° groups) for LA-IP approach for radial artery cannulation. Cannulation time (s), number of attempts, total success rate (%), first attempt success rate were recorded in all patients. Mean radial artery height was increased in 45° group compared to other groups (p < 0.05). Distance between skin and radial artery in 45° and 60° groups were statistically significantly decreased compared to 0° group (p < 0.05 for all comparisons). Mean cannulation time of 45° group was statistically decreased compared to other groups (p < 0.05). Number of attempts and total success rate were similar among groups, whereas first attempt success rate was significantly increased in 45° group compared to other groups (p < 0.05). Mean arterial height of the first attempt successful group was statistically increased compared to the first attempt failed group (p < 0.001) and mean cannulation time and mean number of attempts were also negatively correlated with arterial height (p < 0.001; for all comparisons). The 45° wrist angle increment might be advantageous in US-guided LA-IP radial artery cannulation in elderly patients in view of cannulation time and first attempt success rate.