Qin Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qin Wu has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Feng Ouyang
Department of Radiology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, China; Clinical Research Center for Medical Imaging in Jiangxi Province, Nanchang, China
9 shared publications - Xianjun Zeng
Department of Radiology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, Nanchang, China
9 shared publications - Jie Liu
Department of Radiology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, China; Clinical Research Center for Medical Imaging in Jiangxi Province, Nanchang, China
5 shared publications - Laisheng Pan
Department of Neurosurgery, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, China 413006210176@.ncu.edu.cn
5 shared publications - Bo Wang
Department of Radiology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, China
4 shared publications - Lianjiang Lv
Department of Radiology, The First Affiliated Hospital, Jiangxi Medical College, Nanchang University, China
4 shared publications
Latest Publications
- 11 July 2026
- Published by Springer Nature in European Spine Journal
- p. 1-9
Multimodal MRI features of spinal perimedullary versus dural arteriovenous fistulas: an exploratory analysis
Objective Differentiation between spinal dural arteriovenous fistula (SDAVF) and perimedullary arteriovenous fistula (SPAVF) is crucial for treatment planning, but reliable non-invasive modalities remain limited. This study aimed to identify discriminative multimodal MRI features for differentiating SPAVF from SDAVF. Methods This retrospective study enrolled 34 patients (13 SPAVF, 21 SDAVF) confirmed by digital subtraction angiography (DSA) between January 2016 and December 2025. All patients underwent conventional T2-weighted imaging (T2WI), T2-weighted sampling perfection with application-optimized contrasts using different flip-angle evolutions (T2W-SPACE), and contrast-enhanced magnetic resonance angiography (CE-MRA). Two neuroradiologists independently evaluated multimodal imaging characteristics. Diagnostic performance was assessed using receiver operating characteristic (ROC) curve analysis with bootstrap resampling. Results SPAVF predominantly demonstrated anterior/posterior spinal artery supply (84.61% vs. 0%, P < 0.001), multiple feeding arteries (61.54% vs. 4.76%, P < 0.001), and caudal venous drainage (53.85% vs. 9.52%, P = 0.004) compared with SDAVF. On T2W-SPACE, SPAVF exhibited significantly larger maximum PFV caliber (5.04 mm vs. 1.74 mm, P < 0.001), partial flow void signal (76.92% vs. 0%, P < 0.001), and pial surface fistula location (100% vs. 0%, P < 0.001). CE-MRA revealed larger fistula caliber in SPAVF (5.22 mm vs. 3.21 mm, P < 0.001). ROC analysis demonstrated excellent discriminatory power for SPACE maximum PFV caliber (AUC, 0.96; 95% CI 0.85–0.99; P < 0.001) and CE-MRA fistula caliber (AUC, 0.92; 95% CI 0.76–0.98; P < 0.001). Conclusion T2W-SPACE and CE-MRA enables accurate non-invasive differentiation of SPAVF from SDAVF. SPACE maximum PFV caliber and CE-MRA fistula caliber serve as robust quantitative biomarkers, providing reliable preoperative guidance and potentially reducing dependence on diagnostic DSA.
- 11 July 2026
- Published by Springer Nature in European Spine Journal
- p. 1-9
Multimodal MRI features of spinal perimedullary versus dural arteriovenous fistulas: an exploratory analysis
Objective Differentiation between spinal dural arteriovenous fistula (SDAVF) and perimedullary arteriovenous fistula (SPAVF) is crucial for treatment planning, but reliable non-invasive modalities remain limited. This study aimed to identify discriminative multimodal MRI features for differentiating SPAVF from SDAVF. Methods This retrospective study enrolled 34 patients (13 SPAVF, 21 SDAVF) confirmed by digital subtraction angiography (DSA) between January 2016 and December 2025. All patients underwent conventional T2-weighted imaging (T2WI), T2-weighted sampling perfection with application-optimized contrasts using different flip-angle evolutions (T2W-SPACE), and contrast-enhanced magnetic resonance angiography (CE-MRA). Two neuroradiologists independently evaluated multimodal imaging characteristics. Diagnostic performance was assessed using receiver operating characteristic (ROC) curve analysis with bootstrap resampling. Results SPAVF predominantly demonstrated anterior/posterior spinal artery supply (84.61% vs. 0%, P < 0.001), multiple feeding arteries (61.54% vs. 4.76%, P < 0.001), and caudal venous drainage (53.85% vs. 9.52%, P = 0.004) compared with SDAVF. On T2W-SPACE, SPAVF exhibited significantly larger maximum PFV caliber (5.04 mm vs. 1.74 mm, P < 0.001), partial flow void signal (76.92% vs. 0%, P < 0.001), and pial surface fistula location (100% vs. 0%, P < 0.001). CE-MRA revealed larger fistula caliber in SPAVF (5.22 mm vs. 3.21 mm, P < 0.001). ROC analysis demonstrated excellent discriminatory power for SPACE maximum PFV caliber (AUC, 0.96; 95% CI 0.85–0.99; P < 0.001) and CE-MRA fistula caliber (AUC, 0.92; 95% CI 0.76–0.98; P < 0.001). Conclusion T2W-SPACE and CE-MRA enables accurate non-invasive differentiation of SPAVF from SDAVF. SPACE maximum PFV caliber and CE-MRA fistula caliber serve as robust quantitative biomarkers, providing reliable preoperative guidance and potentially reducing dependence on diagnostic DSA.
- Open Access
- 1 July 2026
- Published by Elsevier in European Journal of Radiology
- Vol. 203, 113049
Discrimination of plaque from sluggish-flow-related hyperintense artifact on high-resolution magnetic resonance vessel wall imaging
- 1 July 2026
- Published by Elsevier in European Journal of Radiology
- Vol. 203, 113049
Open AccessDiscrimination of plaque from sluggish-flow-related hyperintense artifact on high-resolution magnetic resonance vessel wall imaging
- Open Access
- 10 February 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Association of local collateral formation on TOF-MRA with plaque characteristics and ischemic stroke in intracranial atherosclerotic stenosis
To investigate the features of local collateral vessel formation at the site of intracranial atherosclerotic stenosis (ICAS) and its relationship with cere
- 10 February 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Open AccessAssociation of local collateral formation on TOF-MRA with plaque characteristics and ischemic stroke in intracranial atherosclerotic stenosis
To investigate the features of local collateral vessel formation at the site of intracranial atherosclerotic stenosis (ICAS) and its relationship with cere
- 17 October 2025
- Published by Elsevier in Clinical Radiology
- Vol. 92, 107131
Intracranial arterial plaque combined with cerebral small vessel disease magnetic resonance features to assess ischemic stroke
- 17 October 2025
- Published by Elsevier in Clinical Radiology
- Vol. 92, 107131
Intracranial arterial plaque combined with cerebral small vessel disease magnetic resonance features to assess ischemic stroke
- 13 June 2025
- Published by Elsevier in European Journal of Radiology
- Vol. 190, 112238
Association of intravascular enhancement sign on 3D T1- weighted TSE sequences with cerebral perfusion and infarction events in moyamoya disease
- 13 June 2025
- Published by Elsevier in European Journal of Radiology
- Vol. 190, 112238
Association of intravascular enhancement sign on 3D T1- weighted TSE sequences with cerebral perfusion and infarction events in moyamoya disease
- 9 January 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (3) , 853-860
Utility of T2-weighted MRI and contrast-enhanced MRA in locating the fistula level of spinal arteriovenous fistula
Objective To investigate the value of routine T2-weighted magnetic resonance imaging (MRI) and contrast-enhanced magnetic resonance angiography (CE-MRA) sequences in locating the fistula level of spinal arteriovenous fistula (SAVF). Methods Retrospectively analyzed the radiological findings of patients with SAVF diagnosed by surgery from May 2018 to September 2024. All patients completed spinal CE-MRA and routine T2-weighted MRI. The imaging manifestations of SAVF lesions on CE-MRA and MRI were summarized and analyzed. Results We enrolled 40 cases with SAVF (average age 58.1 years old, 85.0% male). The majority of fistulas were located in the thoracic (60.0%), followed by the lumbar (27.5%), and cervical (12.5%). Based on CE-MRA images, the fistula of 33 cases (82.5%) with SAVF can be accurately located, the perimedullary varicose vessels of 34 cases (89.47%) can be shown, and the feeding arteries of 27 cases (71.05%) can be identified. Based on T2-weighted MRI, the perimedullary flow voids and T2 hyperintensity were seen in 36 (90.0%) of SAVF cases, the fistula level in 88.9% (32/36) of cases was located at one end of the flow voids within 1 vertebral level, and the flow voids of 72.2% (26/36) cases near the fistula to be more tension. There is no significant difference in the accuracy of routine T2-weighted MRI in locating the fistula level compared to CE-MRA and digital subtraction angiography (DSA). Conclusion Both routine T2-weighted MRI and CE-MRA sequences are valuable in the detection of SAVF fistula, we can locate the fistula level by the clues of the perimedullary varicose vessels.
- 9 January 2025
- Published by Springer Nature in European Spine Journal
- Vol. 34 (3) , 853-860
Utility of T2-weighted MRI and contrast-enhanced MRA in locating the fistula level of spinal arteriovenous fistula
Objective To investigate the value of routine T2-weighted magnetic resonance imaging (MRI) and contrast-enhanced magnetic resonance angiography (CE-MRA) sequences in locating the fistula level of spinal arteriovenous fistula (SAVF). Methods Retrospectively analyzed the radiological findings of patients with SAVF diagnosed by surgery from May 2018 to September 2024. All patients completed spinal CE-MRA and routine T2-weighted MRI. The imaging manifestations of SAVF lesions on CE-MRA and MRI were summarized and analyzed. Results We enrolled 40 cases with SAVF (average age 58.1 years old, 85.0% male). The majority of fistulas were located in the thoracic (60.0%), followed by the lumbar (27.5%), and cervical (12.5%). Based on CE-MRA images, the fistula of 33 cases (82.5%) with SAVF can be accurately located, the perimedullary varicose vessels of 34 cases (89.47%) can be shown, and the feeding arteries of 27 cases (71.05%) can be identified. Based on T2-weighted MRI, the perimedullary flow voids and T2 hyperintensity were seen in 36 (90.0%) of SAVF cases, the fistula level in 88.9% (32/36) of cases was located at one end of the flow voids within 1 vertebral level, and the flow voids of 72.2% (26/36) cases near the fistula to be more tension. There is no significant difference in the accuracy of routine T2-weighted MRI in locating the fistula level compared to CE-MRA and digital subtraction angiography (DSA). Conclusion Both routine T2-weighted MRI and CE-MRA sequences are valuable in the detection of SAVF fistula, we can locate the fistula level by the clues of the perimedullary varicose vessels.
- 8 August 2024
- Published by Elsevier in Clinical Radiology
- Vol. 79 (11) , e1347-e1355
Comparative analysis of imaging features and stroke-related factors between posterior circulation atherosclerosis and intramural hematoma-type dissection
- 8 August 2024
- Published by Elsevier in Clinical Radiology
- Vol. 79 (11) , e1347-e1355
Comparative analysis of imaging features and stroke-related factors between posterior circulation atherosclerosis and intramural hematoma-type dissection
- 7 October 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (12) , 4111-4117
The value of 3D T2-weighted SPACE sequence in the differential diagnosis of spinal arteriovenous fistula and acute transverse myelitis
Objective Spinal arteriovenous fistulas (SAVF) was often neglected and misdiagnosed as acute transverse myelitis (ATM) due to its insidious onset and non-specific clinical symptoms. This study aims to investigate the differential diagnostic value of high-resolution T2-weighted volumetric sequence (3D sampling perfection with application-optimized contrasts using different flip-angle evolutions [SPACE]) in patients with SAVF and ATM. Methods Retrospectively analyzed the clinical and radiological findings of 32 SDAVF patients and 32 ATM patients treated at our institutions from May 2018 to January 2023. They all underwent conventional spinal MRI and T2-SPACE examination, compared their performance in identifying lesions, to estimate the value of T2 SPACE sequence in the diagnosis of SAVF and ATM patients. Results The clue of cauda equina area change (CEAC) in conventional MRI and T2-SPACE sequences is specific for the diagnosis of SAVF. The diagnostic model composed of perimedullary flow voids (PFV) and CEAC has good diagnostic performance (AUCMRI = 0.95; AUCSPACE = 0.935). Compared with conventional MRI, the T2-SPACE sequence has a higher detection rate, sensitivity, and negative predictive value for PFV and CEAC in SAVF patients, but lower specificity and positive predictive value. In T2-SPACE images, there are significant differences in the distribution range, quadrant, and maximum diameter of PFV vessels between SAVF and ATM patients. Moreover, T2-SPACE sequence can determine the site of fistula in most SAVF patients preferably, and the inter-rater agreement was good in the assessment of the fistula. Conclusion The CEAC is a new and useful clue for the diagnosis of thoracolumbar SAVF. And T2-SPACE sequence can more intuitively observe the lesions of SAVF, has good differential diagnostic value for SAVF and ATM patients.
- 7 October 2023
- Published by Springer Nature in European Spine Journal
- Vol. 32 (12) , 4111-4117
The value of 3D T2-weighted SPACE sequence in the differential diagnosis of spinal arteriovenous fistula and acute transverse myelitis
Objective Spinal arteriovenous fistulas (SAVF) was often neglected and misdiagnosed as acute transverse myelitis (ATM) due to its insidious onset and non-specific clinical symptoms. This study aims to investigate the differential diagnostic value of high-resolution T2-weighted volumetric sequence (3D sampling perfection with application-optimized contrasts using different flip-angle evolutions [SPACE]) in patients with SAVF and ATM. Methods Retrospectively analyzed the clinical and radiological findings of 32 SDAVF patients and 32 ATM patients treated at our institutions from May 2018 to January 2023. They all underwent conventional spinal MRI and T2-SPACE examination, compared their performance in identifying lesions, to estimate the value of T2 SPACE sequence in the diagnosis of SAVF and ATM patients. Results The clue of cauda equina area change (CEAC) in conventional MRI and T2-SPACE sequences is specific for the diagnosis of SAVF. The diagnostic model composed of perimedullary flow voids (PFV) and CEAC has good diagnostic performance (AUCMRI = 0.95; AUCSPACE = 0.935). Compared with conventional MRI, the T2-SPACE sequence has a higher detection rate, sensitivity, and negative predictive value for PFV and CEAC in SAVF patients, but lower specificity and positive predictive value. In T2-SPACE images, there are significant differences in the distribution range, quadrant, and maximum diameter of PFV vessels between SAVF and ATM patients. Moreover, T2-SPACE sequence can determine the site of fistula in most SAVF patients preferably, and the inter-rater agreement was good in the assessment of the fistula. Conclusion The CEAC is a new and useful clue for the diagnosis of thoracolumbar SAVF. And T2-SPACE sequence can more intuitively observe the lesions of SAVF, has good differential diagnostic value for SAVF and ATM patients.