Pengli Zhang
Pengli Zhang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Xiaobo Zheng
Institute of Water Resources and Hydropower, Xi’an University of Technology, Xi’an 710048, China
3 shared publications - Yaping Zhao
Institute of Water Resources and Hydropower, Xi’an University of Technology, Xi’an 710048, China
2 shared publications - Yongjian Pu
Institute of Water Resources and Hydropower, Xi’an University of Technology, Xi’an 710048, China
2 shared publications - Bo Ming
State Key Laboratory of Water Engineering Ecology and Environment in Arid Area, Xi’an University of Technology, Xi’an 710048, China
1 shared publication - Hui Lei
Institute of Water Resources and Hydropower, Xi’an University of Technology, Xi’an 710048, China
1 shared publication - Lu Tian
School of Water Resources and Hydroelectric Engineering, Xi’an University of Technology, Xi’an 710048, China
1 shared publication
Latest Publications
- Open Access
Internal Flow Characteristics of Centrifugal Pumps under Different Startup Combination Schemes
Pump station engineering is a water conservancy project used for long-distance water transfer, irrigation and drainage, and urban living and industrial water supply. Centrifugal pumps are one of the main pump types commonly used in pumping stations, and their operation is of considerable importance for the safety, stability, and efficient operation of pumping stations. This paper takes a large pumping station with seven centrifugal pump units as the research object and combines experimental research and numerical simulation. The axial flow velocity uniformity, average cross-sectional deviation angle, and hydraulic loss of the pump inlet section are evaluated, and the internal flow characteristics of the pump under different startup combination conditions are analyzed based on entropy generation and vorticity. This study also explores the operational performance of the pump station under different startup combination conditions, revealing the mutual influence mechanism between different startup combinations of pump stations and the internal and external characteristics of centrifugal pumps and introducing the optimal startup combination scheme for the pump station system. Research results indicate that the difference in energy loss of centrifugal pumps under different startup combinations is mainly manifested in the impeller and guide vane flow channels. For the two existing inlet flow channel structures in the pump station, the unit effectively operates when the inlet flow channel is tilted to the left. The optimal startup combination method of the pump station under different startup combinations is determined.
Open AccessInternal Flow Characteristics of Centrifugal Pumps under Different Startup Combination Schemes
Pump station engineering is a water conservancy project used for long-distance water transfer, irrigation and drainage, and urban living and industrial water supply. Centrifugal pumps are one of the main pump types commonly used in pumping stations, and their operation is of considerable importance for the safety, stability, and efficient operation of pumping stations. This paper takes a large pumping station with seven centrifugal pump units as the research object and combines experimental research and numerical simulation. The axial flow velocity uniformity, average cross-sectional deviation angle, and hydraulic loss of the pump inlet section are evaluated, and the internal flow characteristics of the pump under different startup combination conditions are analyzed based on entropy generation and vorticity. This study also explores the operational performance of the pump station under different startup combination conditions, revealing the mutual influence mechanism between different startup combinations of pump stations and the internal and external characteristics of centrifugal pumps and introducing the optimal startup combination scheme for the pump station system. Research results indicate that the difference in energy loss of centrifugal pumps under different startup combinations is mainly manifested in the impeller and guide vane flow channels. For the two existing inlet flow channel structures in the pump station, the unit effectively operates when the inlet flow channel is tilted to the left. The optimal startup combination method of the pump station under different startup combinations is determined.
- Open Access
Numerical Study on the Influence of Combined Rectification Facilities on the Flow in the Forebay of Pumping Station
The flow pattern of the forebay of the pumping station has a considerable effect on the operating efficiency and stability of the pump unit. A good forebay flow pattern can enable the pump unit to improve efficiency and operating conditions. This study takes a large pumping station as the research object and considers two rectification schemes, namely, a single bottom sill and a “bottom sill + diversion pier”. Without rectification facilities under different start-up schemes, the forebay flow pattern after the addition of rectification facilities is calculated, and the influence of single and combined rectification facilities is analyzed. Results show large-scale undesirable flow structures such as backflow and vortex in the forebay of the original design that without rectification facilities and uneven flow distribution occurs in the operating unit. The addition of a bottom sill in the forebay can control the central water beam from the water diversion pipe. The flow is divided to spread to both sides of the forebay and can be rectified twice after installing the diversion piers. The combined rectifier facility of “bottom sill + diversion pier” is beneficial to disperse incoming flow and make the flow distribution of each unit more uniform. The backflow and vortex inside the forepond are basically eliminated, and the flow state of the forepond is significantly improved.
Open AccessNumerical Study on the Influence of Combined Rectification Facilities on the Flow in the Forebay of Pumping Station
The flow pattern of the forebay of the pumping station has a considerable effect on the operating efficiency and stability of the pump unit. A good forebay flow pattern can enable the pump unit to improve efficiency and operating conditions. This study takes a large pumping station as the research object and considers two rectification schemes, namely, a single bottom sill and a “bottom sill + diversion pier”. Without rectification facilities under different start-up schemes, the forebay flow pattern after the addition of rectification facilities is calculated, and the influence of single and combined rectification facilities is analyzed. Results show large-scale undesirable flow structures such as backflow and vortex in the forebay of the original design that without rectification facilities and uneven flow distribution occurs in the operating unit. The addition of a bottom sill in the forebay can control the central water beam from the water diversion pipe. The flow is divided to spread to both sides of the forebay and can be rectified twice after installing the diversion piers. The combined rectifier facility of “bottom sill + diversion pier” is beneficial to disperse incoming flow and make the flow distribution of each unit more uniform. The backflow and vortex inside the forepond are basically eliminated, and the flow state of the forepond is significantly improved.
- Open Access
- 30 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11869
Unit Operation Combination and Flow Distribution Scheme of Water Pump Station System Based on Genetic Algorithm
Pump station engineering is a water conservancy project that utilizes water pump units for energy transfer and conversion, and safe water transportation. This study ensures the safe and efficient operation of the pumping station system by taking a pump station project containing seven water pump units as the research object. Under the premise that the total water intake of the pumping station is certain, the flow distribution of the pumping station is optimized with the working flow and head as the constraint function, and the minimum operating cost as the objective function, and the required number of operating units is determined to obtain the optimal combination of flow distribution and the corresponding working flow of each operating unit. Compared with previous studies, the novel feature of this study is that a genetic algorithm is used to optimize the power-up combination and rationally distribute the flow, which can minimize the energy consumption and maximize the operation efficiency of the pumping station. Then, a genetic-algorithm-based optimization method is constructed for unit operation combination and flow distribution. The optimized combination of units is evaluated by using the uniformity of flow velocity at the inlet section of the water pump and the average deviation angle of the section as indicators. The results indicate that, when each operating unit in the pump station has the same working flow distribution, the total input power of the pump station is at maximum. As the differences increase in the working flow rates allocated to each operating unit, the total input power of the pump station decreases. Through the proposed schemes, the optimal operating combination and flow distribution of the pump station system can be achieved when the total water intake is constant, thereby enabling efficient operations and creating maximum economic and social benefits.
- 30 October 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (21) , 11869
Open AccessUnit Operation Combination and Flow Distribution Scheme of Water Pump Station System Based on Genetic Algorithm
Pump station engineering is a water conservancy project that utilizes water pump units for energy transfer and conversion, and safe water transportation. This study ensures the safe and efficient operation of the pumping station system by taking a pump station project containing seven water pump units as the research object. Under the premise that the total water intake of the pumping station is certain, the flow distribution of the pumping station is optimized with the working flow and head as the constraint function, and the minimum operating cost as the objective function, and the required number of operating units is determined to obtain the optimal combination of flow distribution and the corresponding working flow of each operating unit. Compared with previous studies, the novel feature of this study is that a genetic algorithm is used to optimize the power-up combination and rationally distribute the flow, which can minimize the energy consumption and maximize the operation efficiency of the pumping station. Then, a genetic-algorithm-based optimization method is constructed for unit operation combination and flow distribution. The optimized combination of units is evaluated by using the uniformity of flow velocity at the inlet section of the water pump and the average deviation angle of the section as indicators. The results indicate that, when each operating unit in the pump station has the same working flow distribution, the total input power of the pump station is at maximum. As the differences increase in the working flow rates allocated to each operating unit, the total input power of the pump station decreases. Through the proposed schemes, the optimal operating combination and flow distribution of the pump station system can be achieved when the total water intake is constant, thereby enabling efficient operations and creating maximum economic and social benefits.
- Open Access
- 9 October 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (19) , 14628
Joint Forecasting Method of Wind and Solar Outputs Considering Temporal and Spatial Correlation
In response to the problem of low forecasting accuracy in wind and solar power outputs, this study proposes a joint forecasting method for wind and solar power outputs by using their spatiotemporal correlation. First, autocorrelation analysis and causal testing are used to screen the forecasting factors. Then, a convolutional neural network–long short-term memory (CNN-LSTM) is constructed and trained to extract features effectively. Finally, the independent, ensemble, and joint forecasting effects are compared, using a certain clean energy base as the research object. Results show that the forecasting accuracy of the ensemble wind and solar power outputs is better than that of independent forecasting. The joint forecasting method can improve the forecasting accuracy of wind power by 20% but slightly affects the forecasting accuracy of solar power.
- 9 October 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (19) , 14628
Open AccessJoint Forecasting Method of Wind and Solar Outputs Considering Temporal and Spatial Correlation
In response to the problem of low forecasting accuracy in wind and solar power outputs, this study proposes a joint forecasting method for wind and solar power outputs by using their spatiotemporal correlation. First, autocorrelation analysis and causal testing are used to screen the forecasting factors. Then, a convolutional neural network–long short-term memory (CNN-LSTM) is constructed and trained to extract features effectively. Finally, the independent, ensemble, and joint forecasting effects are compared, using a certain clean energy base as the research object. Results show that the forecasting accuracy of the ensemble wind and solar power outputs is better than that of independent forecasting. The joint forecasting method can improve the forecasting accuracy of wind power by 20% but slightly affects the forecasting accuracy of solar power.