Peining Zhu
Peining Zhu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Jia Weng
Chaozhou Power Supply Bureau of Guangdong Power Grid Co., Ltd., Chaozhou 521051, China
2 shared publications - Weijie Chen
Chaozhou Power Supply Bureau of Guangdong Power Grid Co., Ltd., Chaozhou 521051, China
2 shared publications - Yuequ Lin
Chaozhou Power Supply Bureau of Guangdong Power Grid Co., Ltd., Chaozhou 521051, China
2 shared publications - Yuke Wang
School of Water Conservancy and Transportation, Zhengzhou University, Zhengzhou, China
2 shared publications - Jisheng Lin
Chaozhou Power Supply Bureau of Guangdong Power Grid Co., Ltd., Chaozhou 521051, China
1 shared publication - Teng Xu
Chaozhou Power Supply Bureau of Guangdong Power Grid Co., Ltd., Chaozhou 521051, China
1 shared publication
Latest Publications
- Open Access
Comparison of Load Transfer Law of Pipe Pile between O-Cell Test and Traditional Static Load Test
In recent years, the detection of offshore pile foundations has received wide attention in engineering. Compared with traditional methods, the O-cell test has unique advantages in offshore pile foundation detection. To study the load transfer characteristics of the O-cell method for pile testing in coastal soft soil foundation, this paper established the pile–soil numerical model to simulate the O-cell and traditional testing processes. The finite element method and equal displacement method are combined to calculate the conversion coefficient and ultimate bearing capacity, and the distribution forms of axial force, side friction resistance, and tip resistance are discussed. The research results show that the O-cell test method and the traditional method have different load transfer forms. By introducing the equal displacement method into the O-cell pile–soil model, the error between the equivalent conversion ultimate bearing capacity and the calculation result of the surcharge method is less than 0.5%, and the O-cell conversion coefficient can be accurately calculated.
Open AccessComparison of Load Transfer Law of Pipe Pile between O-Cell Test and Traditional Static Load Test
In recent years, the detection of offshore pile foundations has received wide attention in engineering. Compared with traditional methods, the O-cell test has unique advantages in offshore pile foundation detection. To study the load transfer characteristics of the O-cell method for pile testing in coastal soft soil foundation, this paper established the pile–soil numerical model to simulate the O-cell and traditional testing processes. The finite element method and equal displacement method are combined to calculate the conversion coefficient and ultimate bearing capacity, and the distribution forms of axial force, side friction resistance, and tip resistance are discussed. The research results show that the O-cell test method and the traditional method have different load transfer forms. By introducing the equal displacement method into the O-cell pile–soil model, the error between the equivalent conversion ultimate bearing capacity and the calculation result of the surcharge method is less than 0.5%, and the O-cell conversion coefficient can be accurately calculated.
- Open Access
Research on Stability of Dam Substation on Inclined Soft Soil Foundation Reinforced by Pile Foundation
For the construction of dam substations in coastal or mountainous areas, inclined soft soil foundations are very common. The unique engineering characteristics of inclined soft soil foundations can bring great difficulties to the construction of dam substations. In this paper, a pile foundation reinforcement dam slope model on an inclined soft soil foundation is established; the influence of different pile spacings, the pile length, and the soft soil foundation angle on the slope safety factor is studied; and the failure mechanism and stability of pile-supported dam slope foundation are analyzed. The research results indicate that pile foundation reinforcement can reduce the deformation of the dam slope foundation and improve stability. The pile layout has an important impact on stability, but a change in the pile spacing has little effect on the settlement surface at the bottom of the dam slope. The pile length has a significant impact on the safety of the slope within a certain range. The main stress area of the pile is 0–2 m above the pile, and its main deformation is the lateral deformation of the upper part of the pile. The research results of this article can provide parameter support and theoretical guidance for the construction of dam substations.
Open AccessResearch on Stability of Dam Substation on Inclined Soft Soil Foundation Reinforced by Pile Foundation
For the construction of dam substations in coastal or mountainous areas, inclined soft soil foundations are very common. The unique engineering characteristics of inclined soft soil foundations can bring great difficulties to the construction of dam substations. In this paper, a pile foundation reinforcement dam slope model on an inclined soft soil foundation is established; the influence of different pile spacings, the pile length, and the soft soil foundation angle on the slope safety factor is studied; and the failure mechanism and stability of pile-supported dam slope foundation are analyzed. The research results indicate that pile foundation reinforcement can reduce the deformation of the dam slope foundation and improve stability. The pile layout has an important impact on stability, but a change in the pile spacing has little effect on the settlement surface at the bottom of the dam slope. The pile length has a significant impact on the safety of the slope within a certain range. The main stress area of the pile is 0–2 m above the pile, and its main deformation is the lateral deformation of the upper part of the pile. The research results of this article can provide parameter support and theoretical guidance for the construction of dam substations.