BNBich N. Nguyen

Bich N. Nguyen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bich N. Nguyen has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of Radiologists and Deep Learning for US Grading of Hepatic Steatosis

    by Pedro Vianna, Sara-Ivana Calce, Pamela Boustros, Cassandra Larocque-Rigney, Laurent Patry-Beaudoin, Yi Hui Luo, Emre Aslan, John Marinos, Talal M. Alamri, Kim-Nhien Vu, et al.

    Background Screening for nonalcoholic fatty liver disease (NAFLD) is suboptimal due to the subjective interpretation of US images. Purpose To evaluate the agreement and diagnostic performance of radiologists and a deep learning model in grading hepatic steatosis in NAFLD at US, with biopsy as the reference standard. Materials and Methods This retrospective study included patients with NAFLD and control patients without hepatic steatosis who underwent abdominal US and contemporaneous liver biopsy from September 2010 to October 2019. Six readers visually graded steatosis on US images twice, 2 weeks apart. Reader agreement was assessed with use of κ statistics. Three deep learning techniques applied to B-mode US images were used to classify dichotomized steatosis grades. Classification performance of human radiologists and the deep learning model for dichotomized steatosis grades (S0, S1, S2, and S3) was assessed with area under the receiver operating characteristic curve (AUC) on a separate test set. Results The study included 199 patients (mean age, 53 years ± 13 [SD]; 101 men). On the test set (n = 52), radiologists had fair interreader agreement (0.34 [95% CI: 0.31, 0.37]) for classifying steatosis grades S0 versus S1 or higher, while AUCs were between 0.49 and 0.84 for radiologists and 0.85 (95% CI: 0.83, 0.87) for the deep learning model. For S0 or S1 versus S2 or S3, radiologists had fair interreader agreement (0.30 [95% CI: 0.27, 0.33]), while AUCs were between 0.57 and 0.76 for radiologists and 0.73 (95% CI: 0.71, 0.75) for the deep learning model. For S2 or lower versus S3, radiologists had fair interreader agreement (0.37 [95% CI: 0.33, 0.40]), while AUCs were between 0.52 and 0.81 for radiologists and 0.67 (95% CI: 0.64, 0.69) for the deep learning model. Conclusion Deep learning approaches applied to B-mode US images provided comparable performance with human readers for detection and grading of hepatic steatosis. Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Tuthill in this issue.


  • Open Access

    The added value of quantitative ultrasound to shear wave elastography for assessment of steatohepatitis in a rat model

    by An Tang, Francois Destrempes, Siavash Kazemirad, Julian Garcia-Duitama, Bich N. Nguyen, Guy Cloutier

    Non-alcoholic fatty liver disease is a highly prevalent condition, which may progress to non-alcoholic steatohepatitis (NASH), an advanced form found in 3 to 5% of the population. As liver biopsy is invasive, there is a need for a non-invasive technique for the assessment of NASH. Due to promising results of shear wave elastography (SWE) in staging this disease, there is a high interest in developing a multi-parametric approach for assessment of liver steatosis within the same ultrasound (US) examination. The goal of this study was to assess the added value of quantitative US (QUS) parameters to SWE, based on random forest classifiers and areas under the ROC curve (AUC). Sixty male Sprague-Dawley rats were either fed a standard chow or a methionine- and choline-deficient diet. Using a research US system (model V1, Verasonics Inc.), SWE measurements were performed while rats were under anesthesia. To generate shear wavefronts within the liver, a linear array US transducer (ATL L7-4, Philips) was used to induce three 40-V 125-μs long radiation force pushes 4 mm apart. For SW tracking, the same transducer was used to acquire plane wave radiofrequency data at a frame rate of 4 kHz; images were reconstructed using the f-k migration algorithm. QUS acquisitions were performed using the same system and transducer. One hundred frames were acquired, migrated, and the echo envelope was obtained with Hilbert transforms. The image post-processing yielded 4 homodyned-K parametric maps within the region-of-interest (ROI), from which 8 features were extracted. The local attenuation coefficient slope within the ROI was also computed using the spectral shift method. QUS parameters improved the classification accuracy of steatohepatitis, liver steatosis, inflammation, and fibrosis compared to SWE alone. For detection of liver steatosis grades 0 vs ≥ 1, ≤ 1 vs ≥ 2, ≤ 2 vs 3, respectively, AUCs increased from 0.70, 0.65, and 0.69 to 0.78, 0.78, and 0.75 (p < 0.001).


  • Determination of the Neutral Axis in Total Ankle Replacement

    by Ha Vo, Barry Tuvel, Bich Nguyen, Trung Le