Marjana Reis Lima Rizzo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marjana Reis Lima Rizzo has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Abraão Kupske
Hospital Moinhos de Vento, Brazil
1 shared publication - Bruna Bressan Valentini
Hospital Moinhos de Vento, Brazil
1 shared publication - Camila Batista de Oliveira Silva
Neuroendocrinology Center, Santa Casa of Porto Alegre, Porto Alegre, Brazil
1 shared publication - Gabriela Furlin
Hospital Moinhos de Vento, Brazil
1 shared publication - Marco Aurelio Gralha de Caneda
From the Multiple Sclerosis and Demyelinating Disorders Unit, Department of Neurology, Hospital Moinhos de Vento, Porto Alegre, Rio Grande do Sul, Brazil
1 shared publication - Maria Cecilia Aragon de Vecino
Hospital Moinhos de Vento, Brazil
1 shared publication
Latest Publications
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 56 (4) , 187-194
Interrater reliability for the detection of cortical lesions on phase-sensitive inversion recovery magnetic resonance imaging in patients with multiple sclerosis
Objective: To assess the reliability of phase-sensitive inversion recovery (PSIR) magnetic resonance imaging (MRI) and its accuracy for determining the topography of demyelinating cortical lesions in patients with multiple sclerosis (MS). Materials and Methods: This was a cross-sectional study conducted at a tertiary referral center for MS and other demyelinating disorders. We assessed the agreement among three raters for the detection and topographic classification of cortical lesions on fluid-attenuated inversion recovery (FLAIR) and PSIR sequences in patients with MS. Results: We recruited 71 patients with MS. The PSIR sequences detected 50% more lesions than did the FLAIR sequences. For detecting cortical lesions, the level of interrater agreement was satisfactory, with a mean free-response kappa (κFR) coefficient of 0.60, whereas the mean κFR for the topographic reclassification of the lesions was 0.57. On PSIR sequences, the raters reclassified 366 lesions (20% of the lesions detected on FLAIR sequences), with excellent interrater agreement. There was a significant correlation between the total number of lesions detected on PSIR sequences and the Expanded Disability Status Scale score (ρ = 0.35; p < 0.001). Conclusion: It seems that PSIR sequences perform better than do FLAIR sequences, with clinically satisfactory interrater agreement, for the detection and topographic classification of cortical lesions. In our sample of patients with MS, the PSIR MRI findings were significantly associated with the disability status, which could influence decisions regarding the treatment of such patients.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 56 (4) , 187-194
Open AccessInterrater reliability for the detection of cortical lesions on phase-sensitive inversion recovery magnetic resonance imaging in patients with multiple sclerosis
Objective: To assess the reliability of phase-sensitive inversion recovery (PSIR) magnetic resonance imaging (MRI) and its accuracy for determining the topography of demyelinating cortical lesions in patients with multiple sclerosis (MS). Materials and Methods: This was a cross-sectional study conducted at a tertiary referral center for MS and other demyelinating disorders. We assessed the agreement among three raters for the detection and topographic classification of cortical lesions on fluid-attenuated inversion recovery (FLAIR) and PSIR sequences in patients with MS. Results: We recruited 71 patients with MS. The PSIR sequences detected 50% more lesions than did the FLAIR sequences. For detecting cortical lesions, the level of interrater agreement was satisfactory, with a mean free-response kappa (κFR) coefficient of 0.60, whereas the mean κFR for the topographic reclassification of the lesions was 0.57. On PSIR sequences, the raters reclassified 366 lesions (20% of the lesions detected on FLAIR sequences), with excellent interrater agreement. There was a significant correlation between the total number of lesions detected on PSIR sequences and the Expanded Disability Status Scale score (ρ = 0.35; p < 0.001). Conclusion: It seems that PSIR sequences perform better than do FLAIR sequences, with clinically satisfactory interrater agreement, for the detection and topographic classification of cortical lesions. In our sample of patients with MS, the PSIR MRI findings were significantly associated with the disability status, which could influence decisions regarding the treatment of such patients.