Borjan Sazdov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Borjan Sazdov has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Charles Nduka
Emteq Ltd. Brighton, U.K.
4 shared publications - Martin Gjoreski
Università della Svizzera Italiana
4 shared publications - Simon Stankoski
Emteq Ltd. Brighton, U.K.
4 shared publications - Bojan Sofronievski
Faculty of Electrical Engineering & Information Technologies, Ss Cyril and Methodius University, Skopje, Macedonia
3 shared publications - Hristijan Gjoreski
Ss. Cyril and Methodius University in Skopje, Skopje, Macedonia
3 shared publications - Ivana Kiprijanovska
Emteq Ltd., Brighton, UK
3 shared publications
Latest Publications
- Open Access
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 48257-48270
Deep Learning for Facial Expression and Human Activity Recognition Using Smart Glasses
Facial Expression Recognition (FER) and Human Activity Recognition (HAR) are key areas in wearable computing, with applications in healthcare, fitness, and human-computer interaction. This study explores the use of Emteq’s OCOsenseTM smart glasses for FER and HAR, which incorporate optomyographic sensors and a 9-axis inertial measurement unit (IMU). Using deep learning (DL) models, including CNNs, ConvLSTM, and STResNet variants, the study compares the performance of FER for six expression classes and HAR for seven different activities. We investigate the impact of the ConvBoost framework on model performance, extending its use beyond HAR with IMU data and introducing end-to-end learning for FER using OCOsenseTM smart glasses. Our findings confirm that ConvBoost effectively improves performance of complex overfitting-prone models. Furthermore, the results also reveal that using ConvBoost in simpler models, such as the 1-dimensional convolutional neural network (CNN 1D), leads to a decrease in F1-score. The best performing models, Attention ConvLSTM for FER and ConvLSTM for HAR (in combination with ConvBoost), achieved a macro F1-score of 0.78 and 0.88, respectively. These results highlight the potential of smart glasses for FER and HAR, establishing benchmark results for future advancements in glasses-based wearable computing.
- 14 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 48257-48270
Open AccessDeep Learning for Facial Expression and Human Activity Recognition Using Smart Glasses
Facial Expression Recognition (FER) and Human Activity Recognition (HAR) are key areas in wearable computing, with applications in healthcare, fitness, and human-computer interaction. This study explores the use of Emteq’s OCOsenseTM smart glasses for FER and HAR, which incorporate optomyographic sensors and a 9-axis inertial measurement unit (IMU). Using deep learning (DL) models, including CNNs, ConvLSTM, and STResNet variants, the study compares the performance of FER for six expression classes and HAR for seven different activities. We investigate the impact of the ConvBoost framework on model performance, extending its use beyond HAR with IMU data and introducing end-to-end learning for FER using OCOsenseTM smart glasses. Our findings confirm that ConvBoost effectively improves performance of complex overfitting-prone models. Furthermore, the results also reveal that using ConvBoost in simpler models, such as the 1-dimensional convolutional neural network (CNN 1D), leads to a decrease in F1-score. The best performing models, Attention ConvLSTM for FER and ConvLSTM for HAR (in combination with ConvBoost), achieved a macro F1-score of 0.78 and 0.88, respectively. These results highlight the potential of smart glasses for FER and HAR, establishing benchmark results for future advancements in glasses-based wearable computing.
- Open Access
- 26 September 2024
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 12 (1) , e59469
Controlled and Real-Life Investigation of Optical Tracking Sensors in Smart Glasses for Monitoring Eating Behavior Using Deep Learning: Cross-Sectional Study
Background: The increasing prevalence of obesity necessitates innovative approaches to better understand this health crisis, particularly given its strong connection to chronic diseases such as diabetes, cancer, and cardiovascular conditions. Monitoring dietary behavior is crucial for designing effective interventions that help decrease obesity prevalence and promote healthy lifestyles. However, traditional dietary tracking methods are limited by participant burden and recall bias. Exploring microlevel eating activities, such as meal duration and chewing frequency, in addition to eating episodes, is crucial due to their substantial relation to obesity and disease risk. Objective: The primary objective of the study was to develop an accurate and noninvasive system for automatically monitoring eating and chewing activities using sensor-equipped smart glasses. The system distinguishes chewing from other facial activities, such as speaking and teeth clenching. The secondary objective was to evaluate the system’s performance on unseen test users using a combination of laboratory-controlled and real-life user studies. Unlike state-of-the-art studies that focus on detecting full eating episodes, our approach provides a more granular analysis by specifically detecting chewing segments within each eating episode. Methods: The study uses OCO optical sensors embedded in smart glasses to monitor facial muscle activations related to eating and chewing activities. The sensors measure relative movements on the skin’s surface in 2 dimensions (X and Y). Data from these sensors are analyzed using deep learning (DL) to distinguish chewing from other facial activities. To address the temporal dependence between chewing events in real life, we integrate a hidden Markov model as an additional component that analyzes the output from the DL model. Results: Statistical tests of mean sensor activations revealed statistically significant differences across all 6 comparison pairs (P<.001) involving 2 sensors (cheeks and temple) and 3 facial activities (eating, clenching, and speaking). These results demonstrate the sensitivity of the sensor data. Furthermore, the convolutional long short-term memory model, which is a combination of convolutional and long short-term memory neural networks, emerged as the best-performing DL model for chewing detection. In controlled laboratory settings, the model achieved an F1-score of 0.91, demonstrating robust performance. In real-life scenarios, the system demonstrated high precision (0.95) and recall (0.82) for detecting eating segments. The chewing rates and the number of chews evaluated in the real-life study showed consistency with expected real-life eating behaviors. Conclusions: The study represents a substantial advancement in dietary monitoring and health technology. By providing a reliable and noninvasive method for tracking eating behavior, it has the potential to revolutionize how dietary data are collected and used. This could lead to more effective health interventions and a better understanding of the factors influencing eating habits and their health implications.
- 26 September 2024
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 12 (1) , e59469
Open AccessControlled and Real-Life Investigation of Optical Tracking Sensors in Smart Glasses for Monitoring Eating Behavior Using Deep Learning: Cross-Sectional Study
Background: The increasing prevalence of obesity necessitates innovative approaches to better understand this health crisis, particularly given its strong connection to chronic diseases such as diabetes, cancer, and cardiovascular conditions. Monitoring dietary behavior is crucial for designing effective interventions that help decrease obesity prevalence and promote healthy lifestyles. However, traditional dietary tracking methods are limited by participant burden and recall bias. Exploring microlevel eating activities, such as meal duration and chewing frequency, in addition to eating episodes, is crucial due to their substantial relation to obesity and disease risk. Objective: The primary objective of the study was to develop an accurate and noninvasive system for automatically monitoring eating and chewing activities using sensor-equipped smart glasses. The system distinguishes chewing from other facial activities, such as speaking and teeth clenching. The secondary objective was to evaluate the system’s performance on unseen test users using a combination of laboratory-controlled and real-life user studies. Unlike state-of-the-art studies that focus on detecting full eating episodes, our approach provides a more granular analysis by specifically detecting chewing segments within each eating episode. Methods: The study uses OCO optical sensors embedded in smart glasses to monitor facial muscle activations related to eating and chewing activities. The sensors measure relative movements on the skin’s surface in 2 dimensions (X and Y). Data from these sensors are analyzed using deep learning (DL) to distinguish chewing from other facial activities. To address the temporal dependence between chewing events in real life, we integrate a hidden Markov model as an additional component that analyzes the output from the DL model. Results: Statistical tests of mean sensor activations revealed statistically significant differences across all 6 comparison pairs (P<.001) involving 2 sensors (cheeks and temple) and 3 facial activities (eating, clenching, and speaking). These results demonstrate the sensitivity of the sensor data. Furthermore, the convolutional long short-term memory model, which is a combination of convolutional and long short-term memory neural networks, emerged as the best-performing DL model for chewing detection. In controlled laboratory settings, the model achieved an F1-score of 0.91, demonstrating robust performance. In real-life scenarios, the system demonstrated high precision (0.95) and recall (0.82) for detecting eating segments. The chewing rates and the number of chews evaluated in the real-life study showed consistency with expected real-life eating behaviors. Conclusions: The study represents a substantial advancement in dietary monitoring and health technology. By providing a reliable and noninvasive method for tracking eating behavior, it has the potential to revolutionize how dietary data are collected and used. This could lead to more effective health interventions and a better understanding of the factors influencing eating habits and their health implications.
- Open Access
- 12 April 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Controlled and Real-Life Investigation of Optical Tracking Sensors in Smart Glasses for Monitoring Eating Behavior Using Deep Learning: Cross-Sectional Study (Preprint)
BACKGROUND The increasing prevalence of obesity necessitates innovative approaches to better understand this health crisis, particularly given its strong connection to chronic diseases such as diabetes, cancer, and cardiovascular conditions. Monitoring dietary behavior is crucial for designing effective interventions that help decrease obesity prevalence and promote healthy lifestyles. However, traditional dietary tracking methods are limited by participant burden and recall bias. Exploring microlevel eating activities, such as meal duration and chewing frequency, in addition to eating episodes, is crucial due to their substantial relation to obesity and disease risk. OBJECTIVE The primary objective of the study was to develop an accurate and noninvasive system for automatically monitoring eating and chewing activities using sensor-equipped smart glasses. The system distinguishes chewing from other facial activities, such as speaking and teeth clenching. The secondary objective was to evaluate the system’s performance on unseen test users using a combination of laboratory-controlled and real-life user studies. Unlike state-of-the-art studies that focus on detecting full eating episodes, our approach provides a more granular analysis by specifically detecting chewing segments within each eating episode. METHODS The study uses OCO optical sensors embedded in smart glasses to monitor facial muscle activations related to eating and chewing activities. The sensors measure relative movements on the skin’s surface in 2 dimensions (X and Y). Data from these sensors are analyzed using deep learning (DL) to distinguish chewing from other facial activities. To address the temporal dependence between chewing events in real life, we integrate a hidden Markov model as an additional component that analyzes the output from the DL model. RESULTS Statistical tests of mean sensor activations revealed statistically significant differences across all 6 comparison pairs (P<.001) involving 2 sensors (cheeks and temple) and 3 facial activities (eating, clenching, and speaking). These results demonstrate the sensitivity of the sensor data. Furthermore, the convolutional long short-term memory model, which is a combination of convolutional and long short-term memory neural networks, emerged as the best-performing DL model for chewing detection. In controlled laboratory settings, the model achieved an F1-score of 0.91, demonstrating robust performance. In real-life scenarios, the system demonstrated high precision (0.95) and recall (0.82) for detecting eating segments. The chewing rates and the number of chews evaluated in the real-life study showed consistency with expected real-life eating behaviors. CONCLUSIONS The study represents a substantial advancement in dietary monitoring and health technology. By providing a reliable and noninvasive method for tracking eating behavior, it has the potential to revolutionize how dietary data are collected and used. This could lead to more effective health interventions and a better understanding of the factors influencing eating habits and their health implications.
- 12 April 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessControlled and Real-Life Investigation of Optical Tracking Sensors in Smart Glasses for Monitoring Eating Behavior Using Deep Learning: Cross-Sectional Study (Preprint)
BACKGROUND The increasing prevalence of obesity necessitates innovative approaches to better understand this health crisis, particularly given its strong connection to chronic diseases such as diabetes, cancer, and cardiovascular conditions. Monitoring dietary behavior is crucial for designing effective interventions that help decrease obesity prevalence and promote healthy lifestyles. However, traditional dietary tracking methods are limited by participant burden and recall bias. Exploring microlevel eating activities, such as meal duration and chewing frequency, in addition to eating episodes, is crucial due to their substantial relation to obesity and disease risk. OBJECTIVE The primary objective of the study was to develop an accurate and noninvasive system for automatically monitoring eating and chewing activities using sensor-equipped smart glasses. The system distinguishes chewing from other facial activities, such as speaking and teeth clenching. The secondary objective was to evaluate the system’s performance on unseen test users using a combination of laboratory-controlled and real-life user studies. Unlike state-of-the-art studies that focus on detecting full eating episodes, our approach provides a more granular analysis by specifically detecting chewing segments within each eating episode. METHODS The study uses OCO optical sensors embedded in smart glasses to monitor facial muscle activations related to eating and chewing activities. The sensors measure relative movements on the skin’s surface in 2 dimensions (X and Y). Data from these sensors are analyzed using deep learning (DL) to distinguish chewing from other facial activities. To address the temporal dependence between chewing events in real life, we integrate a hidden Markov model as an additional component that analyzes the output from the DL model. RESULTS Statistical tests of mean sensor activations revealed statistically significant differences across all 6 comparison pairs (P<.001) involving 2 sensors (cheeks and temple) and 3 facial activities (eating, clenching, and speaking). These results demonstrate the sensitivity of the sensor data. Furthermore, the convolutional long short-term memory model, which is a combination of convolutional and long short-term memory neural networks, emerged as the best-performing DL model for chewing detection. In controlled laboratory settings, the model achieved an F1-score of 0.91, demonstrating robust performance. In real-life scenarios, the system demonstrated high precision (0.95) and recall (0.82) for detecting eating segments. The chewing rates and the number of chews evaluated in the real-life study showed consistency with expected real-life eating behaviors. CONCLUSIONS The study represents a substantial advancement in dietary monitoring and health technology. By providing a reliable and noninvasive method for tracking eating behavior, it has the potential to revolutionize how dietary data are collected and used. This could lead to more effective health interventions and a better understanding of the factors influencing eating habits and their health implications.
- Open Access
- 8 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 592-596
Privacy-aware Human Activity Recognition with Smart Glasses for Digital Therapeutics
Human Activity Recognition (HAR) holds valuable potential as a digital biomarker, offering insights into individuals' physical activities and well-being. Leveraging wearable devices to monitor human activities can serve as an integral component of digital therapeutics, offering valuable insights into an individual's health and behavior. However, privacy concerns in HAR systems pose a significant challenge as users' data can be at risk of exposure and necessitates robust protection measures. To mitigate these concerns, the adoption of privacy-preserving techniques, such as federated learning, becomes necessary. This paper addresses the topic of Privacy-aware Human Activity Recognition (HAR) with Smart Glasses and explores a federated learning approach to achieve accurate recognition while preserving data privacy. The study highlights the trade-off between model complexity, recognition performance, and data privacy. Initially, a comparison was conducted between a complex deep learning network (STResNet) and a simpler deep learning network (DANA). The complex network exhibited an F1-Macro score of 0.87, while the simpler network achieved 0.82. Subsequently, the simpler network was further evaluated by comparing it to its federated learning implementation. The results revealed that the simpler network attained an F1-Macro score of 0.85, whereas federated learning achieved a slightly lower score of 0.80. These findings shed light on the performance disparities between the different approaches.
- 8 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 592-596
Open AccessPrivacy-aware Human Activity Recognition with Smart Glasses for Digital Therapeutics
Human Activity Recognition (HAR) holds valuable potential as a digital biomarker, offering insights into individuals' physical activities and well-being. Leveraging wearable devices to monitor human activities can serve as an integral component of digital therapeutics, offering valuable insights into an individual's health and behavior. However, privacy concerns in HAR systems pose a significant challenge as users' data can be at risk of exposure and necessitates robust protection measures. To mitigate these concerns, the adoption of privacy-preserving techniques, such as federated learning, becomes necessary. This paper addresses the topic of Privacy-aware Human Activity Recognition (HAR) with Smart Glasses and explores a federated learning approach to achieve accurate recognition while preserving data privacy. The study highlights the trade-off between model complexity, recognition performance, and data privacy. Initially, a comparison was conducted between a complex deep learning network (STResNet) and a simpler deep learning network (DANA). The complex network exhibited an F1-Macro score of 0.87, while the simpler network achieved 0.82. Subsequently, the simpler network was further evaluated by comparing it to its federated learning implementation. The results revealed that the simpler network attained an F1-Macro score of 0.85, whereas federated learning achieved a slightly lower score of 0.80. These findings shed light on the performance disparities between the different approaches.