SGSarang Gupta

Sarang Gupta

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sarang Gupta has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Retrograde endoscopic ultrasound-guided entero-enterostomy for the management of a high-output enterocutaneous fistula and ileal stricture in a complex surgical abdomen

    by Sunil Gupta, Eimear Kirby, Sarang Gupta, Katarzyna M. Pawlak, Joao De Rezende-Neto, Jeffrey D. Mosko, Natalia C. Calo

    A 26-year-old man sustained significant traumatic thoracoabdominal injuries following a gunshot. After multiple laparotomies, small-bowel resections, and an extended left hemicolectomy with end-colostomy formation, he developed a high-output enterocutaneous fistula (ECF) and loss of colostomy output. Computed tomography imaging confirmed an ECF from the ileum to the anterior abdominal wall. There was also a long ileal stricture distal to the fistula. Owing to his complex surgical abdomen and the proximity of the ECF to an abdominal flap, surgical reintervention was deemed high risk. He was therefore referred for endoscopic management ([Video 1]). Methylene blue and contrast dye were injected from the skin side of the ECF, filling a dilated loop of small bowel. No downstream passage of contrast was noted ([Fig. 1] a). Retrograde ileoscopy using a pediatric colonoscope revealed a non-traversable benign-appearing ileal stricture, 90 cm proximal to the ileocecal valve (ICV). Contrast injection demonstrated a 10-cm tortuous stricture ([Fig. 1] b), extending to the previously contrast-filled loop of small bowel. Given the length and character of the stricture, endoscopic balloon dilation and enteral stenting were not feasible. We then proceeded to retrograde endoscopic ultrasound (EUS)-guided entero-enterostomy creation. With the aid of a guidewire, and under endoscopic, fluoroscopic, and endosonographic guidance, a linear echoendoscope was advanced into the ileum via the end-colostomy, cecum, and ICV. At 50 cm from the ICV, we identified an adjacent dilated loop of small bowel ([Fig. 1] b, c). Water was instilled through the ECF, with the endosonographic view demonstrating filling, thereby indicating this to be upstream from the ECF. Puncture was performed with a 19-gauge needle, with subsequent aspiration of methylene blue ([Fig. 2] a). We then created an EUS-guided entero-enterostomy with an electrocautery-enhanced 15-mm lumen-apposing metal stent (LAMS; Hot-AXIOS; Boston Scientific, USA) ([Fig. 2] b). Passage of methylene blue and contrast through the stent confirmed its accurate deployment ([Fig. 3]). With the ECF and stricture bypassed, the patient’s colostomy output returned, the ECF resolved, and the abdominal flap healed ([Fig. 4]). Although electrocautery-enhanced lumen apposition with metal stenting is well established, herein we have demonstrated a novel application of this technique in the management of a complex postsurgical trauma patient with a high-output ECF and a deep ileal stricture. Endoscopy_UCTN_Code_TTT_1AO_2AO Article published online: 26 February 2025 © 2024. The Author(s). This article was originally published by Thieme in Endoscopy 2024; 56: E970–E971 as an open access article under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany


  • Open Access

    A multivariable prediction model to stratify risk of 90-day rehospitalization among adults with ulcerative colitis

    by Claudia Dziegielewski, Sarang Gupta, Julia Lombardi, Erin Kelly, Jeffrey D McCurdy, Richmond Sy, Nav Saloojee, Tim Ramsay, Michael Pugliese, Jahanara Begum, et al.

    Background: Individuals with ulcerative colitis (UC) are frequently re-hospitalized for persistent or recurrent severe disease flares. Accurate prediction of the risk of early re-hospitalization at the time of discharge could promote targeted outpatient interventions to reduce this risk. Methods: We conducted a retrospective study in adults with UC admitted to The Ottawa Hospital between 2009 and 2016 for an acute UC-related indication. We ascertained candidate demographic, clinical, and health services predictors through medical records and administrative health databases. We derived and bootstrap validated a multivariable logistic regression model of 90-day UC-related re-hospitalization risk. We chose a probability cut point that maximized Youden’s index to differentiate high-risk from low-risk individuals and assessed model performance. Results: Among 248 UC-related hospitalizations, there were 27 (10.9%) re-hospitalizations within 90 days of discharge. Our multivariable model identified gastroenterologist consultation within the prior year (adjusted odds ratio [aOR] 0.11, 95% confidence interval [CI], 0.04-0.39), male sex (aOR 3.27, 95% CI, 1.33-8.05), length of stay (OR 0.94, 95% CI, 0.88-1.01), and narcotic prescription at discharge (OR 1.96, 95% CI, 0.73-5.27) as significant predictors of 90-day re-hospitalization. The optimism-corrected c-statistic value was 0.78, and the goodness-of-fit test P-value was .09. The chosen probability cut point produced a sensitivity of 77.8%, specificity of 80.9%, positive predictive value (PPV) of 33.0%, and negative predictive value (NPV) of 96.7% in the derivation cohort. Conclusions: A limited set of variables accessible at the point of hospital discharge can reasonably discriminate re-hospitalization risk among individuals with UC. Future studies are required to validate our findings.


  • Open Access

    Endoscopic incisional therapy for giant bridged pseudopolyposis of the esophagus in a patient with upper GI Crohn’s disease

    by Sarang Gupta, Sechiv Jugnundan, Yusuke Fujiyoshi, Sam Seleq, Gary May, Jeffrey D. Mosko


  • Open Access

    Outcomes of endoscopic retrograde cholangiopancreatography performed in the AM versus PM: does procedural timing matter?

    by Nasruddin Sabrie, Nikko Gimpaya, Kareem Khalaf, Maya Deeb, Wedad Mhalawi, Michael Meleka, Daniel C Tham, Ahmed H Mokhtar, Caleb Na, Sophia P Abal, et al.

    Background: ERCP is a technically demanding procedure that carries a high cumulative adverse event (AE) rate of >10%. Identifying risk factors for adverse events is paramount. Procedure timing, as a surrogate for endoscopist fatigue, has been shown to influence key quality metrics in colonoscopy, but data on this relationship in ERCP is sparse. Methods: We conducted a retrospective cohort study of ERCP procedures performed by 5 experienced staff endoscopists, with or without advanced endoscopy fellow (AEF) involvement, from January 1, 2010 to December 1, 2020 at St Michael’s Hospital, Toronto, Ontario, a regional referral center for therapeutic endoscopy. The primary outcome was the difference in rate of selective deep, duct canulation between AM and PM procedures. Results: A total of 5672 ERCP procedures were eligible for inclusion. 2793 (49.2%) procedures were performed in the AM and 2879 procedures (50.8%) were performed in the PM. We found no significant difference in the rate of selective ductal cannulation between AM and PM procedures in the unadjusted (82.8% AM vs. 83.1% P-value = .79) or adjusted (OR = 0.98, 95% CI, 0.85-1.12, P-value = .72) analyses. We found no significant difference in the mean procedural duration or rate of perforation between AM and PM procedures. The rate of immediate bleeding was slightly higher in the AM cohort. Conclusion: In our single-center retrospective study, ERCP quality, including selective cannulation rates and immediate adverse events were not significantly different in procedures performed in the morning compared to those performed in the afternoon.

  • Open Access

    Deeply embedded esophageal fishbone removed by endoscopic submucosal dissection

    by Sechiv Jugnundan, Sarang Gupta, Sunil Gupta, Katarzyna M. Pawlak, Christopher Teshima

    A 50-year-old man presented to the emergency department with chest pain and odynophagia after eating fish. Physical examination and X-ray of the neck were unremarkable. Computed tomography (CT) of the chest showed a fishbone embedded within the muscularis propria of the esophagus ([Fig. 1] a). We then performed an endoscopic ultrasonography (EUS), which localized the fishbone to the posterior wall ([Fig. 2]). A small mucosal defect was also noted. We proceeded with endoscopic submucosal dissection (ESD) to remove the fishbone ([Video 1]). After normal saline and methylene blue had been injected to expand the submucosal space, a Dual-J knife (Olympus, Center Valley, PA) was used to create a mucosal incision, laterally extending the mucosal defect ([Fig. 1] b). The fishbone was exposed; it was positioned perpendicularly to the esophagus, between the circular and longitudinal muscle layers. Using the fishbone as a scaffold, the overlying circular muscle layer was progressively dissected until the right lateral tip of the bone was freed ([Fig. 3]). The exposed tip was grasped with forceps and removed through the overtube ([Fig. 4]). Examination of the defect revealed incised circular muscle fibers, with intact longitudinal fibers ([Fig. 5]). Attempted closure with through-the-scope clips was unsuccessful because of the orientation of the defect. We placed a 10.5 cm × 23 mm fully covered metal stent (Wallflex; Boston Scientific, Marlborough, Massachusetts, USA). Subsequent CT 48 hours later showed appropriate positioning of the stent with no complications. The stent was removed 2 weeks later, and healed mucosa was observed. Foreign body ingestion is frequently encountered [1]. In adults, bony fragments are most common, and tend to become lodged at sharp angulations in the gastrointestinal tract [2]. While guidelines recommend emergent endoscopy in esophageal impaction [3] [4], surgical intervention is typically required for deeply embedded nonvisible foreign bodies [5]. As we have demonstrated, in selected patients, EUS may localize the foreign body and facilitate ESD for safe and effective extraction. Endoscopy_UCTN_Code_TTT_1AO_2AL Article published online: 08 November 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany


  • Open Access

    Retrograde endoscopic ultrasound-guided entero-enterostomy for the management of a high-output enterocutaneous fistula and ileal stricture in a complex surgical abdomen

    by Sunil Gupta, Eimear Kirby, Sarang Gupta, Katarzyna M. Pawlak, Joao De Rezende-Neto, Jeffrey D. Mosko, Natalia C. Calo

    A 26-year-old man sustained significant traumatic thoracoabdominal injuries following a gunshot. After multiple laparotomies, small-bowel resections, and an extended left hemicolectomy with end-colostomy formation, he developed a high-output enterocutaneous fistula (ECF) and loss of colostomy output. Computed tomography imaging confirmed an ECF from the ileum to the anterior abdominal wall. There was also a long ileal stricture distal to the fistula. Owing to his complex surgical abdomen and the proximity of the ECF to an abdominal flap, surgical reintervention was deemed high risk. He was therefore referred for endoscopic management ([Video 1]). Methylene blue and contrast dye were injected from the skin side of the ECF, filling a dilated loop of small bowel. No downstream passage of contrast was noted ([Fig. 1] a). Retrograde ileoscopy using a pediatric colonoscope revealed a non-traversable benign-appearing ileal stricture, 90 cm proximal to the ileocecal valve (ICV). Contrast injection demonstrated a 10-cm tortuous stricture ([Fig. 1] b), extending to the previously contrast-filled loop of small bowel. Given the length and character of the stricture, endoscopic balloon dilation and enteral stenting were not feasible. We then proceeded to retrograde endoscopic ultrasound (EUS)-guided entero-enterostomy creation. With the aid of a guidewire, and under endoscopic, fluoroscopic, and endosonographic guidance, a linear echoendoscope was advanced into the ileum via the end-colostomy, cecum, and ICV. At 50 cm from the ICV, we identified an adjacent dilated loop of small bowel ([Fig. 1] b, c). Water was instilled through the ECF, with the endosonographic view demonstrating filling, thereby indicating this to be upstream from the ECF. Puncture was performed with a 19-gauge needle, with subsequent aspiration of methylene blue ([Fig. 2] a). We then created an EUS-guided entero-enterostomy with an electrocautery-enhanced 15-mm lumen-apposing metal stent (LAMS; Hot-AXIOS; Boston Scientific, USA) ([Fig. 2] b). Passage of methylene blue and contrast through the stent confirmed its accurate deployment ([Fig. 3]). With the ECF and stricture bypassed, the patient’s colostomy output returned, the ECF resolved, and the abdominal flap healed ([Fig. 4]). Although electrocautery-enhanced lumen apposition with metal stenting is well established, herein we have demonstrated a novel application of this technique in the management of a complex postsurgical trauma patient with a high-output ECF and a deep ileal stricture. Endoscopy_UCTN_Code_TTT_1AO_2AO Article published online: 08 November 2024 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/). Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

  • Open Access

    Interobserver Reliability of the Paris Classification for Superficial Gastrointestinal Tract Neoplasms: A Systematic Review

    by Sarang Gupta, Sam Seleq, Nikko Gimpaya, Rishad Khan, Michael A Scaffidi, Rishi Bansal, Samir C Grover

    Background and study aims: The Paris classification characterizes the morphology of superficial gastrointestinal tract neoplasms. This system has been shown to predict the risk of submucosal invasion in certain subtypes of lesions. There is limited data that assesses its agreement amongst endoscopists. We performed a systematic review to summarize the available literature on the interobserver reliability (IOR) of the Paris classification. Methods: We conducted a search through December 2020 for studies reporting IOR of the Paris classification. Studies were included if they quantitatively evaluated the IOR of the Paris classification with at least five participating endoscopists. Two authors independently screened studies and abstracted data using an a priori-designed data collection form. Evaluation of study quality and risk of bias was performed using an adapted version of the Guidelines for Reporting Reliability and Agreement Studies. Results: Of the 1,541 studies retrieved, 5 were included in the review. All studies were observational cohort studies published between 2014 and 2020. The IOR of the Paris classification was moderate amongst all four studies evaluating colorectal neoplasms (range, κ = 0.42 to κ = 0.54) and substantial in one study that evaluated gastric neoplasms (κw = 0.65). An educational intervention was conducted by three studies with variable methodology and no significant change in IOR. Conclusions: IOR of the Paris classification is moderate for superficial colonic neoplasms. Further study is needed to determine the reliability of this system for superficial gastric lesions. Standardized training programs are required to investigate the impact of educational intervention on the Paris classification amongst endoscopists.


  • ACCURACY OF OPTICAL DIAGNOSIS IN ENDOSCOPY AT A TERTIARY ACADEMIC CENTRE

    by Chandni Pattni, Andras B. Fecso, Sechiv Jugnundan, Sarang Gupta, Samir C. Grover, Christopher Teshima, Jeffrey D. Mosko