Cheng Wang
Research Subjects
Cheng Wang has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Jianjun Zhu
Innovation Research Center for Medical Robotics, School of Computer Science and Engineering, Faculty of Innovation Engineering, Macau University of Science and Technology, Macau, China
8 shared publications - Aiguo Song
Southeast University
7 shared publications - Lifeng Zhu
Southeast University
6 shared publications - Gao-Jun Teng
Center of Interventional Radiology & Vascular Surgery, Department of Radiology, Zhongda Hospital, School of Medicine, Southeast University, Nanjing, China
5 shared publications Chichi Li
Macau University of Science and Technology
4 shared publications- Junchen Xiong
Hanglok-Tech Co., Ltd
3 shared publications
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 42, 2990-3008
Bending-Aware Vision Co-Pilot for Intelligent Robotic Assistance in Endovascular Intervention
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Robotics
- Vol. 42, 2990-3008
Bending-Aware Vision Co-Pilot for Intelligent Robotic Assistance in Endovascular Intervention
- 17 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31  (3) , 2510-2519
PDE Modeling and Shape Control for the Flexible Tube of a Bronchoscope Robot
For the issue of lung nodule biopsy, this study investigated an intervention robot system based on bronchoscopy. The flexible tube of the bronchoscope robot has a planar arc structure, which cannot be described using classical second-order string and fourth-order Euler-Bernoulli beam models. This article obtains the partial differential equation (PDE) model of the flexible tube by analyzing the force and energy changes of the cables, using the Cosserat beam model, and combining strain vectors and rotation matrices. Further, based on the dynamic model of the system, specific control strategies are developed for the tension applied to the head of the flexible tube and the motor driving the cables, enabling the flexible tube to achieve the desired position and shape, thereby guiding the movement of the bronchoscope robot. Finally, based on the self-developed bronchoscope robot system, the effectiveness of the proposed methods is validated through comparative experiments.
- 17 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31  (3) , 2510-2519
PDE Modeling and Shape Control for the Flexible Tube of a Bronchoscope Robot
For the issue of lung nodule biopsy, this study investigated an intervention robot system based on bronchoscopy. The flexible tube of the bronchoscope robot has a planar arc structure, which cannot be described using classical second-order string and fourth-order Euler-Bernoulli beam models. This article obtains the partial differential equation (PDE) model of the flexible tube by analyzing the force and energy changes of the cables, using the Cosserat beam model, and combining strain vectors and rotation matrices. Further, based on the dynamic model of the system, specific control strategies are developed for the tension applied to the head of the flexible tube and the motor driving the cables, enabling the flexible tube to achieve the desired position and shape, thereby guiding the movement of the bronchoscope robot. Finally, based on the self-developed bronchoscope robot system, the effectiveness of the proposed methods is validated through comparative experiments.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25  (18) , 34491-34501
A Novel Haptic Feedback-Based Interaction Control Strategy for Robot-Assisted Vascular Interventional Surgery
Robot-assisted vascular interventional surgery (VIS) is an advanced treatment method that uses robotic systems to perform remote surgical procedures. Haptic feedback is crucial for restoring the interventionist’s sense of presence, allowing them to effectively operate instruments and accurately perceive surgical status. However, despite recent advancements, the quality of haptic feedback remains inferior to traditional manual operation, potentially compromising operational safety during surgery. Our previous work involved designing and developing a novel haptic feedback-based leader device that aligns with interventionists’ operating habits and accurately reproduces follower-side operating forces. This article further optimizes the leader device to improve haptic feedback. Furthermore, we propose a safe interaction control strategy that integrates force and morphological features of surgical instruments. Compared to existing methods, the proposed strategy incorporates an important control parameter—morphological features of surgical instruments. Verification results confirm this strategy’s effectiveness, enhancing robot system–interventionist interaction. This research has the potential to provide safer and more efficient treatment options.
- 11 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25  (18) , 34491-34501
A Novel Haptic Feedback-Based Interaction Control Strategy for Robot-Assisted Vascular Interventional Surgery
Robot-assisted vascular interventional surgery (VIS) is an advanced treatment method that uses robotic systems to perform remote surgical procedures. Haptic feedback is crucial for restoring the interventionist’s sense of presence, allowing them to effectively operate instruments and accurately perceive surgical status. However, despite recent advancements, the quality of haptic feedback remains inferior to traditional manual operation, potentially compromising operational safety during surgery. Our previous work involved designing and developing a novel haptic feedback-based leader device that aligns with interventionists’ operating habits and accurately reproduces follower-side operating forces. This article further optimizes the leader device to improve haptic feedback. Furthermore, we propose a safe interaction control strategy that integrates force and morphological features of surgical instruments. Compared to existing methods, the proposed strategy incorporates an important control parameter—morphological features of surgical instruments. Verification results confirm this strategy’s effectiveness, enhancing robot system–interventionist interaction. This research has the potential to provide safer and more efficient treatment options.
- 7 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 55  (5) , 788-798
Natural Human–Robot Interaction for Vascular Interventional Surgery: Design and Evaluation of a Leader Device With Haptic Feedback
Robot-assisted vascular interventional surgery is a hot topic in the interdisciplinary field of medical science and engineering, it has important research significance. Compared with traditional manual operation, it shows obvious advantages, such as avoiding the radiation exposure to the interventionist, reducing the workload of the interventionist, improving the precision of the operation, and guaranteeing the safety of the operation. However, the human–robot interaction ability has always been a major challenge that cannot be ignored. In this article, we designed and developed a leader device that enables the interventionists to experience the state of surgical instruments naturally and realistically when operating it, as if they were operating actual surgical instruments. The innovations can be summarized as follows: the structure of the leader device is highly consistent with the interventionist’s operating habit, which greatly reduces the interventionist’s operating difficulty. Haptic feedback in both translational direction and circumferential direction is achieved to provide haptic guidance to the interventionists and improve their surgical presence. The leader device is optimized in both structural design and functional realization compared to existing leader devices. This study has great potential in improving human-robot interaction ability, and could provide a reference for the design and evaluation of the leader device.
- 7 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 55  (5) , 788-798
Natural Human–Robot Interaction for Vascular Interventional Surgery: Design and Evaluation of a Leader Device With Haptic Feedback
Robot-assisted vascular interventional surgery is a hot topic in the interdisciplinary field of medical science and engineering, it has important research significance. Compared with traditional manual operation, it shows obvious advantages, such as avoiding the radiation exposure to the interventionist, reducing the workload of the interventionist, improving the precision of the operation, and guaranteeing the safety of the operation. However, the human–robot interaction ability has always been a major challenge that cannot be ignored. In this article, we designed and developed a leader device that enables the interventionists to experience the state of surgical instruments naturally and realistically when operating it, as if they were operating actual surgical instruments. The innovations can be summarized as follows: the structure of the leader device is highly consistent with the interventionist’s operating habit, which greatly reduces the interventionist’s operating difficulty. Haptic feedback in both translational direction and circumferential direction is achieved to provide haptic guidance to the interventionists and improve their surgical presence. The leader device is optimized in both structural design and functional realization compared to existing leader devices. This study has great potential in improving human-robot interaction ability, and could provide a reference for the design and evaluation of the leader device.
- 9 July 2025
- Published by Springer Nature
- p. 116-131
A Highly Efficient Segmentation Method for Abdominal Multi-organs on Laptop
- 9 July 2025
- Published by Springer Nature
- p. 116-131
A Highly Efficient Segmentation Method for Abdominal Multi-organs on Laptop
- 6 May 2025
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 123, 102562
A diffusion-stimulated CT-US registration model with self-supervised learning and synthetic-to-real domain adaptation
- 6 May 2025
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 123, 102562
A diffusion-stimulated CT-US registration model with self-supervised learning and synthetic-to-real domain adaptation
- Open Access
- 18 April 2025
- Published by MDPI AG in Preprints.org
ToothSC-SAM: A Novel Network Model Based on Skip-Connections and SAM for Tooth Segmentation in CBCT Images
This study focuses on the major challenges in addressing the critical limitation of requiring extensive annotated datasets for tooth segmentation from cone-beam computed tomography (CBCT) images, which are essential for clinical patient treatment. Through the modeling process, we found that there are two bottlenecks in the existing deep learning methods: First, the labeling time of a single CBCT case is high, which seriously restricts the clinical application; Second, the number of labeled data influences the performance of the model significantly. Hence, in this paper, we propose a novel two-stage prompt-based network, named ToothSC-SAM, which integrates 3D-SAM with skip-connections for high-resolution tooth segmentation with minimal annotation requirements. The Network first extracts the ROI (Region of Interest) of teeth in the first stage. Then, in the second stage, we use the dots within the ROI as a prompt and send it to a 3D-SAM with skip-connection network for precise tooth segmentation. Finally, we implement tooth labeling and restore CBCT image size through the position provided by the prompt to achieve high-resolution tooth segmentation and labeling. Our method outperforms the SAM approach that directly processes CBCT images by introducing a simple additional prompt step. Moreover, the proposed method performance is approximately 93% of that achieved under the complete supervision baseline, while the annotation cost has been reduced from several hours to just a few minutes. These results highlight the network’s potential to transform dental image analysis by significantly reducing the annotation burden while maintaining clinical-grade accuracy.
- 18 April 2025
- Published by MDPI AG in Preprints.org
Open AccessToothSC-SAM: A Novel Network Model Based on Skip-Connections and SAM for Tooth Segmentation in CBCT Images
This study focuses on the major challenges in addressing the critical limitation of requiring extensive annotated datasets for tooth segmentation from cone-beam computed tomography (CBCT) images, which are essential for clinical patient treatment. Through the modeling process, we found that there are two bottlenecks in the existing deep learning methods: First, the labeling time of a single CBCT case is high, which seriously restricts the clinical application; Second, the number of labeled data influences the performance of the model significantly. Hence, in this paper, we propose a novel two-stage prompt-based network, named ToothSC-SAM, which integrates 3D-SAM with skip-connections for high-resolution tooth segmentation with minimal annotation requirements. The Network first extracts the ROI (Region of Interest) of teeth in the first stage. Then, in the second stage, we use the dots within the ROI as a prompt and send it to a 3D-SAM with skip-connection network for precise tooth segmentation. Finally, we implement tooth labeling and restore CBCT image size through the position provided by the prompt to achieve high-resolution tooth segmentation and labeling. Our method outperforms the SAM approach that directly processes CBCT images by introducing a simple additional prompt step. Moreover, the proposed method performance is approximately 93% of that achieved under the complete supervision baseline, while the annotation cost has been reduced from several hours to just a few minutes. These results highlight the network’s potential to transform dental image analysis by significantly reducing the annotation burden while maintaining clinical-grade accuracy.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7  (2) , 542-549
Computed Tomography and Ultrasound-Guided Robotic Assistance in Percutaneous Puncture in Abdominal Phantom and Porcine Liver Models
Percutaneous puncture is a pivotal technique in diagnosing and treating hepatic lesions; however, traditional manual puncture methods rely heavily on the expertise of medical practitioners. This study aimed to evaluate the feasibility, safety, and efficacy of percutaneous needle placement through the innovative utilization of computed tomography–ultrasound fusion-guided robotic assistance in abdominal phantom and porcine liver models. The abdominal phantom and eight Bama miniature pigs were selected as experimental subjects. Two puncture methods (handheld and robot-assisted puncture) were administered to each simulated tumor with an 18-gauge biopsy needle. All pigs exhibited stable conditions without any complications following the puncture. The Euclidean distance between the needle tip and the predetermined target point of robot-assisted puncture was 3.30 ± 1.48 mm in the pig model and 2.15 ± 0.82 mm in the phantom model. The planning time required for the physician to perform robot-assisted needle insertion was 8.25 ± 2.59 min. Robot-assisted needle insertion in percutaneous puncture was accurate and safe in the pig liver model, highlighting its feasibility and potential clinical application.
- 12 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 7  (2) , 542-549
Computed Tomography and Ultrasound-Guided Robotic Assistance in Percutaneous Puncture in Abdominal Phantom and Porcine Liver Models
Percutaneous puncture is a pivotal technique in diagnosing and treating hepatic lesions; however, traditional manual puncture methods rely heavily on the expertise of medical practitioners. This study aimed to evaluate the feasibility, safety, and efficacy of percutaneous needle placement through the innovative utilization of computed tomography–ultrasound fusion-guided robotic assistance in abdominal phantom and porcine liver models. The abdominal phantom and eight Bama miniature pigs were selected as experimental subjects. Two puncture methods (handheld and robot-assisted puncture) were administered to each simulated tumor with an 18-gauge biopsy needle. All pigs exhibited stable conditions without any complications following the puncture. The Euclidean distance between the needle tip and the predetermined target point of robot-assisted puncture was 3.30 ± 1.48 mm in the pig model and 2.15 ± 0.82 mm in the phantom model. The planning time required for the physician to perform robot-assisted needle insertion was 8.25 ± 2.59 min. Robot-assisted needle insertion in percutaneous puncture was accurate and safe in the pig liver model, highlighting its feasibility and potential clinical application.
- Open Access
- 12 February 2025
- Published by Springer Nature in Research Square
Enhancing Endovascular Interventions with A Robotic System with Vision-Based Collaborative Assistance
Visual feedback derived from digital subtraction angiography (DSA) images is indispensable for guiding interventional decisions during vascular procedures, as real-time DSA imaging provides critical information about the precise positioning of instruments within the vasculature. Excessive bending of the guidewire or microwire tip can pose significant risks, including potential damage to the intimal surface. To address this challenge, this study aims to integrate DSA-based visual feedback into the closed-loop control of an endovascular robotic system, thereby enhancing its safety and intelligence to prevent excessive wire bending. Building on prior work, we propose a distributed hardware and software architecture for the robotic system. This architecture enables robust support for various combinations of interventional instruments while ensuring efficient and reliable transmission of data and commands between system modules. A key innovation is the introduction of vision-based collaborative assistance, which utilizes DSA images to segment the interventional instrument and calculate its bending energy based on the wire’s curvature. This calculated energy is then constrained through nonlinear thresholds to establish a closed-loop control logic. The vascular interventional robotic system was deployed in a standard interventional operating room and evaluated through experiments involving vascular phantoms and animal models. These evaluations demonstrated the system’s capabilities in teleoperation, low communication latency across modules, and improved procedural safety and intelligence facilitated by the vision co-pilot. Quantitative results indicated that the vision co-pilot significantly reduced excessive bending of the microwire tip, enabling smoother, safer, and more efficient completion of interventional tasks.
- 12 February 2025
- Published by Springer Nature in Research Square
Open AccessEnhancing Endovascular Interventions with A Robotic System with Vision-Based Collaborative Assistance
Visual feedback derived from digital subtraction angiography (DSA) images is indispensable for guiding interventional decisions during vascular procedures, as real-time DSA imaging provides critical information about the precise positioning of instruments within the vasculature. Excessive bending of the guidewire or microwire tip can pose significant risks, including potential damage to the intimal surface. To address this challenge, this study aims to integrate DSA-based visual feedback into the closed-loop control of an endovascular robotic system, thereby enhancing its safety and intelligence to prevent excessive wire bending. Building on prior work, we propose a distributed hardware and software architecture for the robotic system. This architecture enables robust support for various combinations of interventional instruments while ensuring efficient and reliable transmission of data and commands between system modules. A key innovation is the introduction of vision-based collaborative assistance, which utilizes DSA images to segment the interventional instrument and calculate its bending energy based on the wire’s curvature. This calculated energy is then constrained through nonlinear thresholds to establish a closed-loop control logic. The vascular interventional robotic system was deployed in a standard interventional operating room and evaluated through experiments involving vascular phantoms and animal models. These evaluations demonstrated the system’s capabilities in teleoperation, low communication latency across modules, and improved procedural safety and intelligence facilitated by the vision co-pilot. Quantitative results indicated that the vision co-pilot significantly reduced excessive bending of the microwire tip, enabling smoother, safer, and more efficient completion of interventional tasks.
- 17 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9  (12) , 10819-10826
MPC Design of a Continuum Robot for Pulmonary Interventional Surgery Using Koopman Operators
This study focuses on the flexible tube of a bronchoscope robot used in pulmonary intervention surgery, which is considered as a continuum robot. The dynamics model is proposed based on the Koopman operator, leveraging real data to solve for the system matrix parameters accurately. To enhance control precision, we designed a model predictive control (MPC) algorithm aimed at tracking the desired curvature and deflection angles of the flexible tube. The MPC controller uses real-time data from electromagnetic sensors to adjust the tube shape, ensuring accurate and responsive manipulation. The effectiveness of the proposed algorithm are validated through extensive experiments conducted on the Binary experimental platform. Compared with the traditional open-loop control method, the proposed algorithm has achieved significant improvements in tracking performance and operational reliability. Each system state error of the proposed algorithm is smaller, which means that better tracking performance can be obtained under the proposed MPC scheme.
- 17 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9  (12) , 10819-10826
MPC Design of a Continuum Robot for Pulmonary Interventional Surgery Using Koopman Operators
This study focuses on the flexible tube of a bronchoscope robot used in pulmonary intervention surgery, which is considered as a continuum robot. The dynamics model is proposed based on the Koopman operator, leveraging real data to solve for the system matrix parameters accurately. To enhance control precision, we designed a model predictive control (MPC) algorithm aimed at tracking the desired curvature and deflection angles of the flexible tube. The MPC controller uses real-time data from electromagnetic sensors to adjust the tube shape, ensuring accurate and responsive manipulation. The effectiveness of the proposed algorithm are validated through extensive experiments conducted on the Binary experimental platform. Compared with the traditional open-loop control method, the proposed algorithm has achieved significant improvements in tracking performance and operational reliability. Each system state error of the proposed algorithm is smaller, which means that better tracking performance can be obtained under the proposed MPC scheme.