Simko O. Ramadan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Simko O. Ramadan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Chro H. Othman1 shared publication
- Fahmi F. Muhammadsharif
Department of Physics, Faculty of Science and Health, Koya University, Koya 44023, Iraq
1 shared publication - Khalid N. Sediq
Department of Physics, Faculty of Science and Health, Koya University, Koya KOY45, Kurdistan Region – F.R. Iraq
1 shared publication - Mohammed M. Sabri
Department of Physics, Faculty of Science and Health, Koya University, Koya KOY45, Kurdistan Region - F.R. Iraq
1 shared publication - Shalaw Zrar Sedeeq
Department of Physics, Faculty of Science and Health, Koya University, Koya, Iraq
1 shared publication
Latest Publications
- Open Access
- 1 July 2025
- Published by Koya University in ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY
- Vol. 13 (2) , 314-325
Modification of the Optical Properties of Polyvinyl Alcohol through Incorporating Cu2O Nanoparticles Prepared by Laser Ablation
A focused, high‐intensity pulsed laser ablated 99.9% - pure copper targets submerged in deionized water and in Polyvinyl alcohol (PVA) solution, respectively, was utilized to produce Cu2O nanoparticles (NPs). Nano-plasmonic cuprous oxide was incorporated using the nanosecond Nd: YAG pulsed laser ablation in liquids technique, which advances the physiochemical characteristics of Cu2O/PVA nanocomposite. Optical characterization was carried out for the induced Cu2O NPs and Cu2O/PVA nanocomposites with six different mass concentrations of Cu2O. The concentrations of the Cu2O NPs were 0.007, 0.017, 0.027, 0.04, 0.047, and 0.057 mg/mL in the PVA matrix. X-ray diffraction confirms that copper ions were reduced to form crystalline Cu2O NPs. Furthermore, DLS showed the presence of NP agglomeration, which revealed polydispersity of Cu2O NPs. The band gap of pristine PVA, determined from Tauc plots, was 5.00 eV. The optical band gap decreased progressively with increasing mass concentration of Cu2O NPs. This band-gap reduction is attributed to changes in the PVA electronic structure caused by incorporated Cu2O NPs. A distinctive feature of this work is the use of pulsed-laser ablation in liquid to generate plasmonic Cu2O NPs and incorporate them in situ into PVA at room temperature in a single step; NP concentration was precisely controlled by the number of laser pulses.
- 1 July 2025
- Published by Koya University in ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY
- Vol. 13 (2) , 314-325
Open AccessModification of the Optical Properties of Polyvinyl Alcohol through Incorporating Cu2O Nanoparticles Prepared by Laser Ablation
A focused, high‐intensity pulsed laser ablated 99.9% - pure copper targets submerged in deionized water and in Polyvinyl alcohol (PVA) solution, respectively, was utilized to produce Cu2O nanoparticles (NPs). Nano-plasmonic cuprous oxide was incorporated using the nanosecond Nd: YAG pulsed laser ablation in liquids technique, which advances the physiochemical characteristics of Cu2O/PVA nanocomposite. Optical characterization was carried out for the induced Cu2O NPs and Cu2O/PVA nanocomposites with six different mass concentrations of Cu2O. The concentrations of the Cu2O NPs were 0.007, 0.017, 0.027, 0.04, 0.047, and 0.057 mg/mL in the PVA matrix. X-ray diffraction confirms that copper ions were reduced to form crystalline Cu2O NPs. Furthermore, DLS showed the presence of NP agglomeration, which revealed polydispersity of Cu2O NPs. The band gap of pristine PVA, determined from Tauc plots, was 5.00 eV. The optical band gap decreased progressively with increasing mass concentration of Cu2O NPs. This band-gap reduction is attributed to changes in the PVA electronic structure caused by incorporated Cu2O NPs. A distinctive feature of this work is the use of pulsed-laser ablation in liquid to generate plasmonic Cu2O NPs and incorporate them in situ into PVA at room temperature in a single step; NP concentration was precisely controlled by the number of laser pulses.
- Open Access
- 24 August 2023
- Published by Koya University in ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY
- Vol. 11 (2) , 95-98
Design and Study of a Nanocavity-based One-dimensional Photonic Crystal for Potential Applications in Refractive Index Sensing
Refractive index (RI) can be used to identify a particular substance and determine its purity and concentration. The RI of glucose solution with various concentrations can be determined using a distributed Bragg reflective (DBR) device containing a nanocavity. The optical property of the reflection spectrum produced by DBR is sensitive to the variation of the refractive index. In this study, a DBR with a cavity width of 220 nm, located in the middle of the device, is designed and used to sense the variation in the refractive index of glucose at different concentrations. The proposed design showed a sharp dip pattern within the reflection spectrum. The wavelength of the absorption peak was found to be sensitive to trivial variations in the refractive index of glucose solution. Results showed that the variation in the refractive index of glucose within the order of Δn = 0.02 has led to a noticeable shift in the absorption spectrum by Δλ = 2.6 nm. Furthermore, the sensitivity of the proposed device was found to be 130 nm/RIU which is considered high compared with those reported in the literature. Hence, the proposed structure can be a promising optical device for chemical ultrasensing applications.
- 24 August 2023
- Published by Koya University in ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY
- Vol. 11 (2) , 95-98
Open AccessDesign and Study of a Nanocavity-based One-dimensional Photonic Crystal for Potential Applications in Refractive Index Sensing
Refractive index (RI) can be used to identify a particular substance and determine its purity and concentration. The RI of glucose solution with various concentrations can be determined using a distributed Bragg reflective (DBR) device containing a nanocavity. The optical property of the reflection spectrum produced by DBR is sensitive to the variation of the refractive index. In this study, a DBR with a cavity width of 220 nm, located in the middle of the device, is designed and used to sense the variation in the refractive index of glucose at different concentrations. The proposed design showed a sharp dip pattern within the reflection spectrum. The wavelength of the absorption peak was found to be sensitive to trivial variations in the refractive index of glucose solution. Results showed that the variation in the refractive index of glucose within the order of Δn = 0.02 has led to a noticeable shift in the absorption spectrum by Δλ = 2.6 nm. Furthermore, the sensitivity of the proposed device was found to be 130 nm/RIU which is considered high compared with those reported in the literature. Hence, the proposed structure can be a promising optical device for chemical ultrasensing applications.