Khulat Saqi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Khulat Saqi has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ahran D. Arnold
National Heart and Lung Institute, Imperial College London, London, UK
1 shared publication - Alejandra A. Miyazawa
Department of Cardiology, Hammersmith Hospital, Imperial College Healthcare Trust, London, United Kingdom
1 shared publication Amal Muthumala
St Bartholomew’s Hospital and North Middlesex University Hospital , Watford , UK
1 shared publication- Daniel Keene
National Heart and Lung Institute, Imperial College London , London
1 shared publication - Darrel Parthipan Francis
Imperial College London
1 shared publication - David C. Lefroy
Department of Cardiology, Imperial College NHS Foundation Trust, W12 0HS London, UK
1 shared publication
Latest Publications
- Open Access
- 5 October 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (10)
Left bundle branch pacing with and without anodal capture: impact on ventricular activation pattern and acute haemodynamics
Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference −0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.
- 5 October 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (10)
Open AccessLeft bundle branch pacing with and without anodal capture: impact on ventricular activation pattern and acute haemodynamics
Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14 ms, P < 0.01 and 83 ± 18 vs. 90 ± 15 ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2 V, P < 0.01) but without additional haemodynamic benefit (mean difference −0.2 ± 3.8 mmHg compared with pacing without anodal capture, P = 0.2). Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.