Zhiwen Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhiwen Sun has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Dawei Xiang
Department of Electrical Engineering, College of Electronic and Information Engineering, Tongji University, Shanghai, China
2 shared publications - Hao Li
College of Electric Power Engineering, Shanghai University of Electric Power, Shanghai, China
2 shared publications - Chen Yang
Department of Electrical Engineering, College of Electronics and Information Engineering, Tongji University, Shanghai, China
1 shared publication - Guolin Lu
Department of Electrical Engineering, College of Electronic and Information Engineering, Tongji University, Shanghai, China
1 shared publication - Hangkang Hu
Department of Electrical Engineering, College of Electronic and Information Engineering, Tongji University, Shanghai, China
1 shared publication - Hongsheng Zhong
Department of Electrical Engineering, College of Electronic and Information Engineering, Tongji University, Shanghai, China
1 shared publication
Latest Publications
- 2 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (1) , 1577-1588
Improved Oscillation Method for High-Frequency Magnetic Core Loss Measurement
Accurate measurement of magnetic core loss is of great significance for magnetic and thermal design for power electronic converters operating at high frequencies. However, the commonly used two-winding method is difficult for ultrahigh frequency measurement due to the voltage and current phase error. The oscillation method presents a promising solution for high-frequency applications, albeit with the drawback of additional switch losses. To address these challenges, this study proposes an improved oscillation method that eliminates the switch on -state loss by removing it from the resonant circuit and reduces the switch off -state loss by a transformer utilizing its impedance amplification effect. This article begins with an analysis of the underlying principle, including the improved oscillation test circuit, procedure, and core loss calculation algorithm. Next, implementation considerations such as the magnetizing coil, test conditions, switch components, and compensation for other losses are discussed. Finally, experimental work is conducted to evaluate the proposed method at 300 kHz, 2 MHz, and 10 MHz. The results validate its superior accuracy at high frequencies while effectively mitigating switch losses to negligible levels.
- 2 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (1) , 1577-1588
Improved Oscillation Method for High-Frequency Magnetic Core Loss Measurement
Accurate measurement of magnetic core loss is of great significance for magnetic and thermal design for power electronic converters operating at high frequencies. However, the commonly used two-winding method is difficult for ultrahigh frequency measurement due to the voltage and current phase error. The oscillation method presents a promising solution for high-frequency applications, albeit with the drawback of additional switch losses. To address these challenges, this study proposes an improved oscillation method that eliminates the switch on -state loss by removing it from the resonant circuit and reduces the switch off -state loss by a transformer utilizing its impedance amplification effect. This article begins with an analysis of the underlying principle, including the improved oscillation test circuit, procedure, and core loss calculation algorithm. Next, implementation considerations such as the magnetizing coil, test conditions, switch components, and compensation for other losses are discussed. Finally, experimental work is conducted to evaluate the proposed method at 300 kHz, 2 MHz, and 10 MHz. The results validate its superior accuracy at high frequencies while effectively mitigating switch losses to negligible levels.
- 10 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (8) , 9800-9811
Online Monitoring of Lithium-Ion Battery Impedance Using DC–DC Converter Self-Excited Switching Oscillations
Online impedance monitoring is an important technique for acquiring the condition information of a Lithium-ion (Li-ion) battery (e.g., state of charge and internal temperature) for safe, reliable, and efficient operation. The existing ac excitation/response method ( Z ( jω ) = V ( jω )/ I ( jω )) may interact with the system's normal operation leading to an interrupted measurement and degraded accuracy. To address these challenges, this article proposes an online continuous battery impedance monitoring method by using the high-frequency (HF) electromagnetic oscillations excited by the dc–dc converter's pulse width modulation (PWM) switching in a battery system. First, the principle of the switching oscillation method is analyzed, including the HF equivalent circuit and the analytical expression of the battery switching oscillation current. Then, a battery impedance online monitoring scheme is proposed, where the switching oscillation current is captured by a specially designed noncontact HF oscillation sensor, and the oscillation features including frequency and damping ratio are extracted by the half-power bandwidth algorithm to estimate the battery's equivalent resistance and reactance. Finally, experimental work was carried out on a 24 V/ 6.6 Ah 18 650 Li-ion battery module test system, and the results demonstrate excellent performance, including continuous real-time monitoring, high accuracy, and good robustness to converter dynamic operation.
- 10 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (8) , 9800-9811
Online Monitoring of Lithium-Ion Battery Impedance Using DC–DC Converter Self-Excited Switching Oscillations
Online impedance monitoring is an important technique for acquiring the condition information of a Lithium-ion (Li-ion) battery (e.g., state of charge and internal temperature) for safe, reliable, and efficient operation. The existing ac excitation/response method ( Z ( jω ) = V ( jω )/ I ( jω )) may interact with the system's normal operation leading to an interrupted measurement and degraded accuracy. To address these challenges, this article proposes an online continuous battery impedance monitoring method by using the high-frequency (HF) electromagnetic oscillations excited by the dc–dc converter's pulse width modulation (PWM) switching in a battery system. First, the principle of the switching oscillation method is analyzed, including the HF equivalent circuit and the analytical expression of the battery switching oscillation current. Then, a battery impedance online monitoring scheme is proposed, where the switching oscillation current is captured by a specially designed noncontact HF oscillation sensor, and the oscillation features including frequency and damping ratio are extracted by the half-power bandwidth algorithm to estimate the battery's equivalent resistance and reactance. Finally, experimental work was carried out on a 24 V/ 6.6 Ah 18 650 Li-ion battery module test system, and the results demonstrate excellent performance, including continuous real-time monitoring, high accuracy, and good robustness to converter dynamic operation.