Pengfei Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pengfei Song has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Xikai Liu
Ningbo Institute of Technology, Beihang University, Ningbo 315800, China; Zhejiang Engineering Research Center of Precision Electromagnetic Control Technology and Equipment, Ningbo 315800, China
7 shared publications - Bangcheng Han
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China
5 shared publications - Tong Wen
School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China
4 shared publications - Yimin Chen
School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China
4 shared publications - Shuai Dou
Institute of Large-Scale Scientific Facility and the Centre for Zero Magnetic Field Science, Beihang University, Beijing, China
2 shared publications - Ya Deng
Zhejiang Engineering Research Center of Precision Electromagnetic Control Technology and Equipment, Ningbo Institute of Technology, Beihang University, Ningbo 315800, China
2 shared publications
Latest Publications
- 4 May 2026
- Published by Elsevier in Measurement
- Vol. 279
Highly uniform magnetic moment-free coils based on image method for suppressing the ferromagnetic boundary coupling effect
- 4 May 2026
- Published by Elsevier in Measurement
- Vol. 279
Highly uniform magnetic moment-free coils based on image method for suppressing the ferromagnetic boundary coupling effect
- Open Access
- 5 January 2026
- Published by Elsevier in NeuroImage
- Vol. 326, 121692
Portable and dynamic magnetoencephalography measurement using compact MSR by precise two-stage magnetic field adjustment and control strategy
- 5 January 2026
- Published by Elsevier in NeuroImage
- Vol. 326, 121692
Open AccessPortable and dynamic magnetoencephalography measurement using compact MSR by precise two-stage magnetic field adjustment and control strategy
- 17 September 2025
- Published by Elsevier in Measurement
- Vol. 257
Hybrid suppression of ferromagnetic boundary coupling combining the self-shielding and image methods for magnetoencephalography measurements
- 17 September 2025
- Published by Elsevier in Measurement
- Vol. 257
Hybrid suppression of ferromagnetic boundary coupling combining the self-shielding and image methods for magnetoencephalography measurements
- 1 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (2) , 1178-1186
High-Resolution and Wearable Magnetocardiography (MCG) Measurement With Active-Passive Coupling Magnetic Control Method
Magnetocardiography (MCG) enables passive detection of weak magnetic fields generated by the heart with high sensitivity, which can offer valuable information for diagnosing and treating heart conditions. Due to the limitations of the geomagnetic field and unknown magnetic interference, the MCG signals are often overwhelmed by high levels of magnetic noise. In this paper, we propose the design of a high-resolution and movable MCG system comprised of an active-passive coupling magnetic control (AP-CMC) system and a wearable multi-channel signal detection array. The system realizes the MCG measurement at the same time as the AP-CMC system eliminates interference in real time, i.e., simultaneous control and simultaneous measurement. Dynamic MCG signal measurements were successfully conducted, obtaining typical characteristic features of MCG signals. Our method shows promise in enhancing the accuracy and expanding the scope of MCG measurement applications, thereby offering valuable insights for the early diagnosis and precise localization of heart diseases.
- 1 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 30 (2) , 1178-1186
High-Resolution and Wearable Magnetocardiography (MCG) Measurement With Active-Passive Coupling Magnetic Control Method
Magnetocardiography (MCG) enables passive detection of weak magnetic fields generated by the heart with high sensitivity, which can offer valuable information for diagnosing and treating heart conditions. Due to the limitations of the geomagnetic field and unknown magnetic interference, the MCG signals are often overwhelmed by high levels of magnetic noise. In this paper, we propose the design of a high-resolution and movable MCG system comprised of an active-passive coupling magnetic control (AP-CMC) system and a wearable multi-channel signal detection array. The system realizes the MCG measurement at the same time as the AP-CMC system eliminates interference in real time, i.e., simultaneous control and simultaneous measurement. Dynamic MCG signal measurements were successfully conducted, obtaining typical characteristic features of MCG signals. Our method shows promise in enhancing the accuracy and expanding the scope of MCG measurement applications, thereby offering valuable insights for the early diagnosis and precise localization of heart diseases.
- Open Access
Sinusoidal Rotor Core Shape for Low Torque Ripple in Hollow-Cup Machines
Due to the configuration of coreless stators and two synchronously rotated rotors, hollow-cup machines (HCMs) enjoy the merits of negligible cogging torque and core loss. Consequently, HCMs have been successfully employed as high-speed electric machines in the aerospace field, which requires high precision and low thermal dissipation. However, the permanent magnet (PM) thickness and air-gap length of conventional HCM are uniform, resulting in various harmonics in the air-gap flux density as well as back-EMF. These harmonics inevitably produce an electromagnetic torque ripple, which has not met the increasing demand for ultraprecision in recent years. Since the inner rotor of HCMs only consists of an iron core, this paper proposes a novel sinusoidal-shaped inner rotor, which can change the harmonics of air-gap permeance, to adjust the harmonics of air-gap flux density and back-EMF. HCMs with the proposed inner rotors have a significant 87% reduction in torque ripple compared to conventional HCMs. Meanwhile, compared to conventional methods, HCMs with the proposed inner rotor exhibit comparable torque ripple and higher average torque.
Open AccessSinusoidal Rotor Core Shape for Low Torque Ripple in Hollow-Cup Machines
Due to the configuration of coreless stators and two synchronously rotated rotors, hollow-cup machines (HCMs) enjoy the merits of negligible cogging torque and core loss. Consequently, HCMs have been successfully employed as high-speed electric machines in the aerospace field, which requires high precision and low thermal dissipation. However, the permanent magnet (PM) thickness and air-gap length of conventional HCM are uniform, resulting in various harmonics in the air-gap flux density as well as back-EMF. These harmonics inevitably produce an electromagnetic torque ripple, which has not met the increasing demand for ultraprecision in recent years. Since the inner rotor of HCMs only consists of an iron core, this paper proposes a novel sinusoidal-shaped inner rotor, which can change the harmonics of air-gap permeance, to adjust the harmonics of air-gap flux density and back-EMF. HCMs with the proposed inner rotors have a significant 87% reduction in torque ripple compared to conventional HCMs. Meanwhile, compared to conventional methods, HCMs with the proposed inner rotor exhibit comparable torque ripple and higher average torque.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (4) , 6923-6934
Suppression of the Ferromagnetic Boundary Coupling and Precision Control of Magnetic Field with the Self-Shielding Method
Ferromagnetic boundary coupling is one key factor that limits the control accuracy of the residual magnetic field in the magnetic shielding room. Usually the image method is utilized to suppress the coupling, but the tolerance for door slit and holes of the image method is poor. Here, we propose the self-shielding method for suppressing the ferromagnetic boundary coupling with higher coupling suppression ability and better tolerance for door slit and holes. Two sets of biplane coils for one axis are designed for achieving uniform magnetic field in the target area and nearzero magnetic field in the shielding area near the passive metal shielding layer simultaneously. We have determined the analysis method and design process of the self-shielding method, and verified its feasibility by experimental test. The proposed method can provide new ideas for improving the control accuracy of the residual magnetic field in the magnetic shielding room, ensuring the smooth progress of magnetoencephalography measurement.
- 29 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (4) , 6923-6934
Suppression of the Ferromagnetic Boundary Coupling and Precision Control of Magnetic Field with the Self-Shielding Method
Ferromagnetic boundary coupling is one key factor that limits the control accuracy of the residual magnetic field in the magnetic shielding room. Usually the image method is utilized to suppress the coupling, but the tolerance for door slit and holes of the image method is poor. Here, we propose the self-shielding method for suppressing the ferromagnetic boundary coupling with higher coupling suppression ability and better tolerance for door slit and holes. Two sets of biplane coils for one axis are designed for achieving uniform magnetic field in the target area and nearzero magnetic field in the shielding area near the passive metal shielding layer simultaneously. We have determined the analysis method and design process of the self-shielding method, and verified its feasibility by experimental test. The proposed method can provide new ideas for improving the control accuracy of the residual magnetic field in the magnetic shielding room, ensuring the smooth progress of magnetoencephalography measurement.
- 9 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 431-435
Design of Self-Shielding Uniform Coils Based on Bat Algorithm
The ferromagnetic boundary coupling effect is an important factor affecting the coil uniformity, and the non-moment coils (NMCs) design method is often used to solve this problem. This paper proposes a non-moment planar coils (NMPCs) design method based on bat algorithm (BA) and self-shielding method, which can inhibit the coupling effect between the coils and the high magnetic permeability shielding layer, and improve the uniformity of the target region. We design Bx and Bz NMPCs, and use finite element software to simulate and calculate, verifying the performance of the method. Compared with ordinary planar coils (OPCs) in the shielding layer, the target region uniformity of this method has been significantly improved, Bx and Bz have increased by a factor of 17.28 and 10.57 respectively. This method can provide a new coil design idea for precise ultra-weak magnetic testing.
- 9 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 431-435
Design of Self-Shielding Uniform Coils Based on Bat Algorithm
The ferromagnetic boundary coupling effect is an important factor affecting the coil uniformity, and the non-moment coils (NMCs) design method is often used to solve this problem. This paper proposes a non-moment planar coils (NMPCs) design method based on bat algorithm (BA) and self-shielding method, which can inhibit the coupling effect between the coils and the high magnetic permeability shielding layer, and improve the uniformity of the target region. We design Bx and Bz NMPCs, and use finite element software to simulate and calculate, verifying the performance of the method. Compared with ordinary planar coils (OPCs) in the shielding layer, the target region uniformity of this method has been significantly improved, Bx and Bz have increased by a factor of 17.28 and 10.57 respectively. This method can provide a new coil design idea for precise ultra-weak magnetic testing.
- 9 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 290-294
Research on Magnetic Field Gradient Suppression Methods in Magnetically Shielded Room
The suppression of gradient magnetic fields (GMF) in magnetically shielded room (MSR) can provide the necessary conditions for precision physics experiments, biomagnetic signal measurements and zero-magnetic science research. The bi-planar coil designed by using the target field method (TFM) can generate a high-precision controlled compensating GMF within a certain target area, thus suppressing the original GMF and ultimately increasing the uniformity inside the MSR. In this paper, a total of 5 gradient bi-planar coils (GBC) are designed by using the particle swarm algorithm (PSO) to suppress the GMF, and the effectiveness of the design is demonstrated by finite element simulation. The results show that the gradient bi-planar coils (GBCs) design can effectively suppress the GMF in all directions within the MSR.
- 9 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 290-294
Research on Magnetic Field Gradient Suppression Methods in Magnetically Shielded Room
The suppression of gradient magnetic fields (GMF) in magnetically shielded room (MSR) can provide the necessary conditions for precision physics experiments, biomagnetic signal measurements and zero-magnetic science research. The bi-planar coil designed by using the target field method (TFM) can generate a high-precision controlled compensating GMF within a certain target area, thus suppressing the original GMF and ultimately increasing the uniformity inside the MSR. In this paper, a total of 5 gradient bi-planar coils (GBC) are designed by using the particle swarm algorithm (PSO) to suppress the GMF, and the effectiveness of the design is demonstrated by finite element simulation. The results show that the gradient bi-planar coils (GBCs) design can effectively suppress the GMF in all directions within the MSR.