Adam D. Yock
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Adam D. Yock has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Eric Shinohara
Department of Radiation Oncology Vanderbilt University Medical Center Nashville Tennessee USA
2 shared publicationsManuel Morales‐Paliza
Department of Radiation Oncology Vanderbilt University Medical Center Nashville Tennessee USA
2 shared publicationsAnnie Cooney
Department of Radiation Oncology Vanderbilt University Medical Center Nashville Tennessee USA
1 shared publicationAshwin Shinde
Department of Radiation Oncology Vanderbilt University Medical Center Nashville Tennessee USA
1 shared publicationAustin Kirschner
Department of Radiation Oncology Vanderbilt University Medical Center Nashville Tennessee USA
1 shared publicationBeshoi Grees
Radiation Oncology, Vanderbilt University Medical Center, 2220 Pierce Ave, Preston Research Bldg, Nashville, Tennessee, 37232, UNITED STATES
1 shared publication
Latest Publications
- Open Access
- 29 November 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (1) , e14221
Empirical analysis of a plan‐of‐the‐day strategy to approximate daily online reoptimization for prostate CBCT‐guided adaptive radiotherapy
Purpose: Adaptive radiotherapy (ART) can improve the dose delivered to the patient in the presence of anatomic variations. However, the required time, effort, and clinical resources are intensive. This work analyzed a plan‐of‐the‐day (POD) approach on clinical patients treated with online ART to explore implementations that balance dosimetric benefit and clinical resource cost.Methods: Eight patients treated to the prostate and proximal seminal vesicles with 26 fractions of CBCT‐guided, daily online ART were retrospectively analyzed. With a plan library composed of daily adaptive plans from the initial week of treatment and the original plan, the effect of a POD approach starting the following week was investigated by simulating use of these previously generated plans under 3‐ and 6‐degree‐of‐freedom patient alignment. The plan selected for each treatment was that from the library that maximized the Dice similarity coefficient of the clinical target volume with that of the current treatment fraction. The resulting distribution of several target coverage and organ‐at‐risk dose metrics are described relative to those achieved with the daily online reoptimized adaptive technique.Results: The values of target coverage and organ‐at‐risk dose metrics varied across patients and metrics. The POD schemas closely approximated the reference values from a fully reoptimized adaptive plan yet required less than 20% of the reoptimization effort. The POD schemas also had a much greater effect on target coverage metrics than 6‐degree‐of‐freedom registration did. Organ‐at‐risk dose metrics also varied considerably across patients but did not exhibit a consistent dependence on the particular schema.Conclusions: POD schemas were able to achieve the vast majority of the dosimetric benefit of daily online ART with a small fraction of the online reoptimization effort. Strategies like this might allow for more practical and strategic implementation of ART so as to benefit a greater number of patients.
- 29 November 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (1) , e14221
Open AccessEmpirical analysis of a plan‐of‐the‐day strategy to approximate daily online reoptimization for prostate CBCT‐guided adaptive radiotherapy
Purpose: Adaptive radiotherapy (ART) can improve the dose delivered to the patient in the presence of anatomic variations. However, the required time, effort, and clinical resources are intensive. This work analyzed a plan‐of‐the‐day (POD) approach on clinical patients treated with online ART to explore implementations that balance dosimetric benefit and clinical resource cost.Methods: Eight patients treated to the prostate and proximal seminal vesicles with 26 fractions of CBCT‐guided, daily online ART were retrospectively analyzed. With a plan library composed of daily adaptive plans from the initial week of treatment and the original plan, the effect of a POD approach starting the following week was investigated by simulating use of these previously generated plans under 3‐ and 6‐degree‐of‐freedom patient alignment. The plan selected for each treatment was that from the library that maximized the Dice similarity coefficient of the clinical target volume with that of the current treatment fraction. The resulting distribution of several target coverage and organ‐at‐risk dose metrics are described relative to those achieved with the daily online reoptimized adaptive technique.Results: The values of target coverage and organ‐at‐risk dose metrics varied across patients and metrics. The POD schemas closely approximated the reference values from a fully reoptimized adaptive plan yet required less than 20% of the reoptimization effort. The POD schemas also had a much greater effect on target coverage metrics than 6‐degree‐of‐freedom registration did. Organ‐at‐risk dose metrics also varied considerably across patients but did not exhibit a consistent dependence on the particular schema.Conclusions: POD schemas were able to achieve the vast majority of the dosimetric benefit of daily online ART with a small fraction of the online reoptimization effort. Strategies like this might allow for more practical and strategic implementation of ART so as to benefit a greater number of patients.
- Open Access
- 27 September 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (19) , 195025
Innovative margin design and optimized isocenter to minimize the normal tissue in target volumes for single-isocenter multi-target stereotactic radiosurgery
Objective. Treating multiple brain metastases in a single plan is a popular radiosurgery technique. However, targets positioned off-isocenter are subject to rotational uncertainties. This work introduces two new planning target volumes (PTVs) that address this increased uncertainty. The volume of normal tissue included in these PTVs when paired with optimized isocenters are evaluated and compared with conventional methods. Approach. Sets of 1000 random multi-target radiosurgery patients were simulated, each patient with a random number of spherical targets (2–10). Each target had a random volume (0.1–15 cc) and was randomly positioned between 5 and 50 mm or 100 mm from isocenter. Two new PTVs (‘LensPTV’ and ‘SwipePTV’) and conventional isotropic PTVs were created using isocenters derived from the center-of-centroids, the center-of-mass, or optimized per PTV type. The total volume of normal tissue in the PTVs for each patient was calculated and compared using 1 mm translations and 0.5°, 1.0°, and 2.0° rotations. Main results. Using the new PTVs and/or using optimized isocenters decreased the total volume of normal tissue in the PTVs per patient. The SwipePTV, in particular, provided the greatest decrease. Compared to the SwipePTV, the LensPTV and the conventional isotropic PTV included an extra 0.68 and 0.73 cc of normal tissue per patient (median), respectively, when using 50 mm max distance to isocenter and 1° max rotation angle. Under these conditions, 25% of patients had extra volume of normal tissue ≥ 0.96 and 1.04 cc. When using 100 mm max distance to isocenter and 2° max rotation angle, 25% of patients had extra volume of normal tissue ≥ 4.35 and 5.75 cc. Significance. PTVs like those presented here, especially when paired with optimized isocenters, can decrease the total volume of included normal tissue and reduce the risk of toxicity without compromising target coverage.
- 27 September 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (19) , 195025
Open AccessInnovative margin design and optimized isocenter to minimize the normal tissue in target volumes for single-isocenter multi-target stereotactic radiosurgery
Objective. Treating multiple brain metastases in a single plan is a popular radiosurgery technique. However, targets positioned off-isocenter are subject to rotational uncertainties. This work introduces two new planning target volumes (PTVs) that address this increased uncertainty. The volume of normal tissue included in these PTVs when paired with optimized isocenters are evaluated and compared with conventional methods. Approach. Sets of 1000 random multi-target radiosurgery patients were simulated, each patient with a random number of spherical targets (2–10). Each target had a random volume (0.1–15 cc) and was randomly positioned between 5 and 50 mm or 100 mm from isocenter. Two new PTVs (‘LensPTV’ and ‘SwipePTV’) and conventional isotropic PTVs were created using isocenters derived from the center-of-centroids, the center-of-mass, or optimized per PTV type. The total volume of normal tissue in the PTVs for each patient was calculated and compared using 1 mm translations and 0.5°, 1.0°, and 2.0° rotations. Main results. Using the new PTVs and/or using optimized isocenters decreased the total volume of normal tissue in the PTVs per patient. The SwipePTV, in particular, provided the greatest decrease. Compared to the SwipePTV, the LensPTV and the conventional isotropic PTV included an extra 0.68 and 0.73 cc of normal tissue per patient (median), respectively, when using 50 mm max distance to isocenter and 1° max rotation angle. Under these conditions, 25% of patients had extra volume of normal tissue ≥ 0.96 and 1.04 cc. When using 100 mm max distance to isocenter and 2° max rotation angle, 25% of patients had extra volume of normal tissue ≥ 4.35 and 5.75 cc. Significance. PTVs like those presented here, especially when paired with optimized isocenters, can decrease the total volume of included normal tissue and reduce the risk of toxicity without compromising target coverage.
- Open Access
- 5 June 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (10) , e14060
Triggering daily online adaptive radiotherapy in the pelvis: Dosimetric effects and procedural implications of trigger parameter‐value selection
Background: Online adaptive radiotherapy (ART) can address dosimetric consequences of variations in anatomy by creating a new plan during treatment. However, ART is time‐ and labor‐intensive and should be implemented in a resource‐conscious way. Adaptive triggers composed of parameter‐value pairs may direct the judicious use of online ART.Purpose: This work analyzed our clinical experience using CBCT‐based daily online ART to demonstrate how a conceptual framework based on adaptive triggers affects the dosimetric and procedural impact of ART.Methods: Sixteen patients across several pelvic sites were treated with CBCT‐based daily online ART. Differences in standardized dose metrics were compared between the original plan, the original plan recalculated on the daily anatomy, and an adaptive plan. For each metric, trigger values were analyzed in terms of the proportion of treatments adapted and the distribution of metric values.Results: Target coverage metrics were compromised due to anatomic variation with the average change per treatment ranging from ‐0.90 to ‐0.05 Gy, ‐0.47 to ‐0.02 Gy, ‐0.31 to ‐0.01 Gy, and ‐12.45% to ‐2.65% for PTV D99%, PTV D95%, CTV D99%, and CTV V100%, respectively. These were improved using the adaptive plan (‐0.03 to 0.01 Gy, ‐0.02 to 0.00 Gy, ‐0.03 to 0.00 Gy, and ‐4.70% to 0.00%, respectively). Increasingly strict triggers resulted in a non‐linear increase in the proportion of treatments adapted and improved the distribution of metric values with diminishing returns. Some organ‐at‐risk (OAR) metrics were compromised by anatomic variation and improved using the adaptive plan, but changes in most OAR metrics were randomly distributed.Conclusions: Daily online ART improved target coverage across multiple pelvic treatment sites and techniques. These effects were larger than those for OAR metrics, suggesting that maintaining target coverage was our primary benefit of CBCT‐based daily online ART. Analyses like these can determine online ART triggers from a cost‐benefit perspective.
- 5 June 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (10) , e14060
Open AccessTriggering daily online adaptive radiotherapy in the pelvis: Dosimetric effects and procedural implications of trigger parameter‐value selection
Background: Online adaptive radiotherapy (ART) can address dosimetric consequences of variations in anatomy by creating a new plan during treatment. However, ART is time‐ and labor‐intensive and should be implemented in a resource‐conscious way. Adaptive triggers composed of parameter‐value pairs may direct the judicious use of online ART.Purpose: This work analyzed our clinical experience using CBCT‐based daily online ART to demonstrate how a conceptual framework based on adaptive triggers affects the dosimetric and procedural impact of ART.Methods: Sixteen patients across several pelvic sites were treated with CBCT‐based daily online ART. Differences in standardized dose metrics were compared between the original plan, the original plan recalculated on the daily anatomy, and an adaptive plan. For each metric, trigger values were analyzed in terms of the proportion of treatments adapted and the distribution of metric values.Results: Target coverage metrics were compromised due to anatomic variation with the average change per treatment ranging from ‐0.90 to ‐0.05 Gy, ‐0.47 to ‐0.02 Gy, ‐0.31 to ‐0.01 Gy, and ‐12.45% to ‐2.65% for PTV D99%, PTV D95%, CTV D99%, and CTV V100%, respectively. These were improved using the adaptive plan (‐0.03 to 0.01 Gy, ‐0.02 to 0.00 Gy, ‐0.03 to 0.00 Gy, and ‐4.70% to 0.00%, respectively). Increasingly strict triggers resulted in a non‐linear increase in the proportion of treatments adapted and improved the distribution of metric values with diminishing returns. Some organ‐at‐risk (OAR) metrics were compromised by anatomic variation and improved using the adaptive plan, but changes in most OAR metrics were randomly distributed.Conclusions: Daily online ART improved target coverage across multiple pelvic treatment sites and techniques. These effects were larger than those for OAR metrics, suggesting that maintaining target coverage was our primary benefit of CBCT‐based daily online ART. Analyses like these can determine online ART triggers from a cost‐benefit perspective.