Li Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Li Wang has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Zi-Qi Li
4 shared publicationsZiqi Li
4 shared publicationsLusong Yu
3 shared publicationsHaowei Gu
2 shared publicationsJunsheng Su
2 shared publicationsLiang Zhang
2 shared publications
Latest Publications
- Open Access
- 12 October 2026
- Published by Elsevier in SSRN Electronic Journal
Experimental Bond Behavior of Square Concrete-Filled Steel Tubes under Varying Ambient Temperatures
To clarify the temperature-dependent interfacial bonding behavior of square concrete-filled steel tube (SCFST) members, 16 specimens were tested under varying thermal conditions. The effects of ambient temperature (T), steel tube width-to-thickness ratio (B/t), and concrete compressive strength (fcu) on bond response were examined. Results show that bond capacity is strongly affected by temperature and specimen geometry. Lower temperatures enhance bond strength; increasing B/t progressively declines interfacial bond performance, whereas higher-strength concrete increases it. These findings highlight the coupled effects of thermal conditions, geometry, and concrete strength on SCFST bond behavior. Surface strain distributions at different loading stages were also revealed. Transverse strain at both ends exceeded mid-span. Under ambient and elevated temperatures, mid-span longitudinal strain was higher than at both ends; however, at low temperatures, longitudinal deformation was more pronounced near the ends. Calculation equations were proposed to estimate peak bond resistance and associated interfacial slip at the limit state. Comparisons with American and modified European code models show the proposed formulas agree best with experimental data. Furthermore, a temperature-dependent constitutive model was developed from measured bond–slip responses, effectively capturing progressive bond resistance degradation at the steel–concrete interface during loading.
- 12 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessExperimental Bond Behavior of Square Concrete-Filled Steel Tubes under Varying Ambient Temperatures
To clarify the temperature-dependent interfacial bonding behavior of square concrete-filled steel tube (SCFST) members, 16 specimens were tested under varying thermal conditions. The effects of ambient temperature (T), steel tube width-to-thickness ratio (B/t), and concrete compressive strength (fcu) on bond response were examined. Results show that bond capacity is strongly affected by temperature and specimen geometry. Lower temperatures enhance bond strength; increasing B/t progressively declines interfacial bond performance, whereas higher-strength concrete increases it. These findings highlight the coupled effects of thermal conditions, geometry, and concrete strength on SCFST bond behavior. Surface strain distributions at different loading stages were also revealed. Transverse strain at both ends exceeded mid-span. Under ambient and elevated temperatures, mid-span longitudinal strain was higher than at both ends; however, at low temperatures, longitudinal deformation was more pronounced near the ends. Calculation equations were proposed to estimate peak bond resistance and associated interfacial slip at the limit state. Comparisons with American and modified European code models show the proposed formulas agree best with experimental data. Furthermore, a temperature-dependent constitutive model was developed from measured bond–slip responses, effectively capturing progressive bond resistance degradation at the steel–concrete interface during loading.
- Open Access
- 10 September 2026
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 28 (7) , 1790-1812
Seismic performance of prefabricated bridge piers with grouted sleeve connections: a comparative study of pier configurations
Prefabricated bridge structures have gained increasing attention in modern civil engineering due to their advantages in construction efficiency and quality control. However, their application in seismic regions remains limited, primarily due to insufficient understanding of their seismic performance and damage mechanisms. This study investigates the seismic behavior of prefabricated double-column piers with grouted sleeve connections using a high-fidelity finite element model developed in ABAQUS. A quasi-static loading protocol is employed to evaluate key performance indicators, including hysteretic response, ductility, energy dissipation capacity, and damage evolution. The seismic performance of prefabricated piers is systematically compared with that of cast-in-place counterparts. Furthermore, the influence of pier configuration (single-, double-, and three-column systems) on seismic performance is examined. The results indicate that, although prefabricated double-column piers exhibit slightly reduced ductility, they demonstrate superior peak load capacity and enhanced energy dissipation capacity compared to cast-in-place piers. Among different configurations, double-column piers show the most balanced force distribution and minimal damage concentration. In contrast, single- and three-column systems exhibit significantly lower load capacity and energy dissipation, with reductions of 66.4 % and 23.3 %, respectively. These findings provide valuable insights into the seismic design of prefabricated bridge piers and support their application in seismic regions.
- 10 September 2026
- Published by JVE International Ltd. in Journal of Vibroengineering
- Vol. 28 (7) , 1790-1812
Open AccessSeismic performance of prefabricated bridge piers with grouted sleeve connections: a comparative study of pier configurations
Prefabricated bridge structures have gained increasing attention in modern civil engineering due to their advantages in construction efficiency and quality control. However, their application in seismic regions remains limited, primarily due to insufficient understanding of their seismic performance and damage mechanisms. This study investigates the seismic behavior of prefabricated double-column piers with grouted sleeve connections using a high-fidelity finite element model developed in ABAQUS. A quasi-static loading protocol is employed to evaluate key performance indicators, including hysteretic response, ductility, energy dissipation capacity, and damage evolution. The seismic performance of prefabricated piers is systematically compared with that of cast-in-place counterparts. Furthermore, the influence of pier configuration (single-, double-, and three-column systems) on seismic performance is examined. The results indicate that, although prefabricated double-column piers exhibit slightly reduced ductility, they demonstrate superior peak load capacity and enhanced energy dissipation capacity compared to cast-in-place piers. Among different configurations, double-column piers show the most balanced force distribution and minimal damage concentration. In contrast, single- and three-column systems exhibit significantly lower load capacity and energy dissipation, with reductions of 66.4 % and 23.3 %, respectively. These findings provide valuable insights into the seismic design of prefabricated bridge piers and support their application in seismic regions.
- Open Access
Bond Transfer Mechanisms and Slip Evolution in High-Strength Concrete-Filled Steel Tubes Under Extreme Temperatures Through Push-Out Tests and Finite Element Simulations
The effects of wide-ranging service temperatures on interfacial bond transfer and slip evolution in high-strength concrete-filled steel tube members have not yet been systematically characterized. A test program involving 15 circular specimens was carried out at temperatures between −60 °C and 60 °C with steel tube wall thicknesses of 2 mm, 3 mm, and 4 mm. Particular attention was given to interface failure patterns, slip development, and stress transfer during loading. Cooling markedly enhanced the interfacial resistance, whereas heating produced a moderate reduction. The increase observed at subzero temperatures was smaller than that commonly reported for conventional concrete-filled steel tubes. Bond capacity also declined as the diameter-to-thickness ratio increased because of reduced confinement from the steel tube. Regression of the experimental data produced expressions for ultimate bond strength and the associated slip. A piecewise constitutive relation was then formulated to represent the complete bond–slip process. The proposed relation was implemented in ABAQUS through distributed nonlinear connector elements and temperature-dependent material properties. Numerical predictions showed close agreement with the measured load–slip responses, characteristic loads, and stress distributions. These results provide a modeling basis for HSCFST members exposed to severe cold and large temperature fluctuations.
Open AccessBond Transfer Mechanisms and Slip Evolution in High-Strength Concrete-Filled Steel Tubes Under Extreme Temperatures Through Push-Out Tests and Finite Element Simulations
The effects of wide-ranging service temperatures on interfacial bond transfer and slip evolution in high-strength concrete-filled steel tube members have not yet been systematically characterized. A test program involving 15 circular specimens was carried out at temperatures between −60 °C and 60 °C with steel tube wall thicknesses of 2 mm, 3 mm, and 4 mm. Particular attention was given to interface failure patterns, slip development, and stress transfer during loading. Cooling markedly enhanced the interfacial resistance, whereas heating produced a moderate reduction. The increase observed at subzero temperatures was smaller than that commonly reported for conventional concrete-filled steel tubes. Bond capacity also declined as the diameter-to-thickness ratio increased because of reduced confinement from the steel tube. Regression of the experimental data produced expressions for ultimate bond strength and the associated slip. A piecewise constitutive relation was then formulated to represent the complete bond–slip process. The proposed relation was implemented in ABAQUS through distributed nonlinear connector elements and temperature-dependent material properties. Numerical predictions showed close agreement with the measured load–slip responses, characteristic loads, and stress distributions. These results provide a modeling basis for HSCFST members exposed to severe cold and large temperature fluctuations.
- 9 June 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 215
Study on quasi-static test of STCC columns under different ambient temperatures
- 9 June 2025
- Published by Elsevier in Thin-Walled Structures
- Vol. 215
Study on quasi-static test of STCC columns under different ambient temperatures
- 12 March 2025
- Published by Elsevier in Ocean Engineering
- Vol. 326
Lifetime seismic damage evolution and resilience assessment of offshore bridges under height-varying corrosion and scour
- 12 March 2025
- Published by Elsevier in Ocean Engineering
- Vol. 326
Lifetime seismic damage evolution and resilience assessment of offshore bridges under height-varying corrosion and scour
- 18 August 2024
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 32 (16) , 3777-3792
Experimental study on axial compression performance of circular CFST columns considering extreme ambient temperature
- 18 August 2024
- Published by Taylor & Francis in Mechanics of Advanced Materials and Structures
- Vol. 32 (16) , 3777-3792
Experimental study on axial compression performance of circular CFST columns considering extreme ambient temperature