Abhinav Khanna
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Abhinav Khanna has a total of 99 co-authors. Here are the top co-authors by number of shared publications:
Vidit Sharma
Department of Urology, Mayo Clinic, Rochester, MN
5 shared publicationsStephen A. Boorjian
Department of Urology, Mayo Clinic, Rochester, MN
4 shared publications- Stephen A. Boorjian
Department of Urology, Mayo Clinic, Rochester, MN
4 shared publications Igor Frank
Department of Urology, Mayo Clinic, Rochester, MN
3 shared publicationsParas Shah
Department of Urology, Mayo Clinic, Rochester, MN
3 shared publications- Adam T. Froemming
Mayo Clinic, Rochester, USA
2 shared publications
Latest Publications
- 10 October 2026
- Published by Springer Nature in Abdominal Radiology
- p. 1-9
Utility of PSA density velocity in diagnosing prostate cancer on prostate MR
- 10 October 2026
- Published by Springer Nature in Abdominal Radiology
- p. 1-9
Utility of PSA density velocity in diagnosing prostate cancer on prostate MR
- 4 August 2026
- Published by Springer Nature in Abdominal Radiology
- p. 1-12
Deep learning–based prostate cancer diagnosis on MRI with hip prostheses: artifact and sequence effects
- 4 August 2026
- Published by Springer Nature in Abdominal Radiology
- p. 1-12
Deep learning–based prostate cancer diagnosis on MRI with hip prostheses: artifact and sequence effects
- Open Access
- 15 April 2026
- Published by Elsevier in Urology Case Reports
- Vol. 66
A silver lining … in the ureter: Keratinizing squamous metaplasia with a metallic twist
- 15 April 2026
- Published by Elsevier in Urology Case Reports
- Vol. 66
Open AccessA silver lining … in the ureter: Keratinizing squamous metaplasia with a metallic twist
A Simplified Prediction Tool for Metastasis After Nephrectomy With Venous Tumor Thrombectomy for RCC
- 26 May 2025
- Published by Elsevier in European Urology
- Vol. 88 (2) , 212-214
Consolidative Surgery for Advanced Urothelial Carcinoma Following Induction Enfortumab Vedotin and/or Immune Checkpoint Inhibitor Therapy: A Multicenter Analysis
- 26 May 2025
- Published by Elsevier in European Urology
- Vol. 88 (2) , 212-214
Consolidative Surgery for Advanced Urothelial Carcinoma Following Induction Enfortumab Vedotin and/or Immune Checkpoint Inhibitor Therapy: A Multicenter Analysis
- 16 April 2025
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 240 (5) , 739-746
Enhancing Accuracy of Operative Reports with Automated Artificial Intelligence Analysis of Surgical Video
BACKGROUND: The creation of operative reports is a tedious documentation task that increases administrative burden, which is a potential driver of burnout. Additionally, operative reports are inherently subjective and may contain inaccuracies and incomplete information. Recent advances in artificial intelligence (AI) technology have enabled computer vision systems to accurately detect operative steps on surgical video. We aim to develop a platform for the automated creation of video-based AI surgical operative reports in robotic-assisted radical prostatectomy. STUDY DESIGN: An AI computer vision algorithm was used to automatically detect surgical steps. Each step detected on video was mapped to prespecified text, which was then compiled into a narrative AI operative report. The accuracy of the AI operative reports was compared with operative reports written by surgeons, using expert review of raw surgical video footage as the ground truth. RESULTS: A total of 158 cases from a tertiary referral center were included. In surgeon operative reports, 84 cases (53.2%) had at least 1 discrepancy between the operative report and surgical video. Of these, 43 cases (27.2%) had a clinically significant discrepancy based on expert video review. In AI operative reports, 46 cases (29.1%) had at least 1 discrepancy between the operative report and surgical video. Of these, 20 cases (12.7%) had a clinically significant discrepancy. Overall accuracy was higher for AI operative reports compared with surgeon operative reports (87.3% vs 72.8%, p = 0.001). CONCLUSIONS: Operative reports created by AI achieved higher accuracy than those written by surgeons. To our knowledge, this is the first report of automated video-based AI surgical documentation. Future studies are warranted to explore the potential for this novel tool to reduce documentation burden, improve operative report accuracy, promote surgical transparency, and decrease subjectivity in surgical documentation.
- 16 April 2025
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 240 (5) , 739-746
Enhancing Accuracy of Operative Reports with Automated Artificial Intelligence Analysis of Surgical Video
BACKGROUND: The creation of operative reports is a tedious documentation task that increases administrative burden, which is a potential driver of burnout. Additionally, operative reports are inherently subjective and may contain inaccuracies and incomplete information. Recent advances in artificial intelligence (AI) technology have enabled computer vision systems to accurately detect operative steps on surgical video. We aim to develop a platform for the automated creation of video-based AI surgical operative reports in robotic-assisted radical prostatectomy. STUDY DESIGN: An AI computer vision algorithm was used to automatically detect surgical steps. Each step detected on video was mapped to prespecified text, which was then compiled into a narrative AI operative report. The accuracy of the AI operative reports was compared with operative reports written by surgeons, using expert review of raw surgical video footage as the ground truth. RESULTS: A total of 158 cases from a tertiary referral center were included. In surgeon operative reports, 84 cases (53.2%) had at least 1 discrepancy between the operative report and surgical video. Of these, 43 cases (27.2%) had a clinically significant discrepancy based on expert video review. In AI operative reports, 46 cases (29.1%) had at least 1 discrepancy between the operative report and surgical video. Of these, 20 cases (12.7%) had a clinically significant discrepancy. Overall accuracy was higher for AI operative reports compared with surgeon operative reports (87.3% vs 72.8%, p = 0.001). CONCLUSIONS: Operative reports created by AI achieved higher accuracy than those written by surgeons. To our knowledge, this is the first report of automated video-based AI surgical documentation. Future studies are warranted to explore the potential for this novel tool to reduce documentation burden, improve operative report accuracy, promote surgical transparency, and decrease subjectivity in surgical documentation.
- Open Access
- 21 July 2024
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 18 (1) , 1-8
Artificial intelligence model for automated surgical instrument detection and counting: an experimental proof-of-concept study
Background: Retained surgical items (RSI) are preventable events that pose a significant risk to patient safety. Current strategies for preventing RSIs rely heavily on manual instrument counting methods, which are prone to human error. This study evaluates the feasibility and performance of a deep learning-based computer vision model for automated surgical tool detection and counting. Methods: A novel dataset of 1,004 images containing 13,213 surgical tools across 11 categories was developed. The dataset was split into training, validation, and test sets at a 60:20:20 ratio. An artificial intelligence (AI) model was trained on the dataset, and the model’s performance was evaluated using standard object detection metrics, including precision and recall. To simulate a real-world surgical setting, model performance was also evaluated in a dynamic surgical video of instruments being moved in real-time. Results: The model demonstrated high precision (98.5%) and recall (99.9%) in distinguishing surgical tools from the background. It also exhibited excellent performance in differentiating between various surgical tools, with precision ranging from 94.0 to 100% and recall ranging from 97.1 to 100% across 11 tool categories. The model maintained strong performance on a subset of test images containing overlapping tools (precision range: 89.6–100%, and recall range 97.2–98.2%). In a real-time surgical video analysis, the model maintained a correct surgical tool count in all non-transition frames, with a median inference speed of 40.4 frames per second (interquartile range: 4.9). Conclusion: This study demonstrates that using a deep learning-based computer vision model for automated surgical tool detection and counting is feasible. The model’s high precision and real-time inference capabilities highlight its potential to serve as an AI safeguard to potentially improve patient safety and reduce manual burden on surgical staff. Further validation in clinical settings is warranted.
- 21 July 2024
- Published by Springer Nature in Patient Safety in Surgery
- Vol. 18 (1) , 1-8
Open AccessArtificial intelligence model for automated surgical instrument detection and counting: an experimental proof-of-concept study
Background: Retained surgical items (RSI) are preventable events that pose a significant risk to patient safety. Current strategies for preventing RSIs rely heavily on manual instrument counting methods, which are prone to human error. This study evaluates the feasibility and performance of a deep learning-based computer vision model for automated surgical tool detection and counting. Methods: A novel dataset of 1,004 images containing 13,213 surgical tools across 11 categories was developed. The dataset was split into training, validation, and test sets at a 60:20:20 ratio. An artificial intelligence (AI) model was trained on the dataset, and the model’s performance was evaluated using standard object detection metrics, including precision and recall. To simulate a real-world surgical setting, model performance was also evaluated in a dynamic surgical video of instruments being moved in real-time. Results: The model demonstrated high precision (98.5%) and recall (99.9%) in distinguishing surgical tools from the background. It also exhibited excellent performance in differentiating between various surgical tools, with precision ranging from 94.0 to 100% and recall ranging from 97.1 to 100% across 11 tool categories. The model maintained strong performance on a subset of test images containing overlapping tools (precision range: 89.6–100%, and recall range 97.2–98.2%). In a real-time surgical video analysis, the model maintained a correct surgical tool count in all non-transition frames, with a median inference speed of 40.4 frames per second (interquartile range: 4.9). Conclusion: This study demonstrates that using a deep learning-based computer vision model for automated surgical tool detection and counting is feasible. The model’s high precision and real-time inference capabilities highlight its potential to serve as an AI safeguard to potentially improve patient safety and reduce manual burden on surgical staff. Further validation in clinical settings is warranted.