Harshinder Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Harshinder Singh has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
A.C. Jain
Section of Cardiology, Department of Medicine, West Virginia University, Morgantown, WV
1 shared publicationC. Failinger
Section of Cardiology, Department of Medicine, West Virginia University, Morgantown, WV
1 shared publicationD.K. Bhumbla
Eberley College of Arts and Sciences, West Virginia University, Morgantown, WV
1 shared publication
Latest Publications
- 21 November 2005
- Published by Wiley in Echocardiography
- Vol. 22 (10) , 789-796
ORIGINAL INVESTIGATIONS: Comparison of Left Atrial Dimensions by Transesophageal and Transthoracic Echocardiography
Transesophageal echocardiography (TEE) is an established cardiovascular diagnostic technique. Left atrial (LA) size, as measured by transthoracic echocardiography (TTE), is associated with cardiovascular disease and is a risk factor for atrial fibrillation, stroke, death, and the success of cardioversion. Assessment of LA size has not been as well validated on TEE as on TTE. We determined LA size measurements in four standard views in 122 patients undergoing TEE and TTE at the same setting. In this study, we found that measurement of LA dimensions by TEE suffers from significant limitations in all views except the basal long‐axis view (mid‐esophageal level) with transducer plane at 120–150 degrees. This view had the best correlation with transthoracic LA measurements: r = 0.79 for TEE long axis (CI 0.71–0.85), P <.0001. (ECHOCARDIOGRAPHY, Volume 22, November 2005)
- 21 November 2005
- Published by Wiley in Echocardiography
- Vol. 22 (10) , 789-796
ORIGINAL INVESTIGATIONS: Comparison of Left Atrial Dimensions by Transesophageal and Transthoracic Echocardiography
Transesophageal echocardiography (TEE) is an established cardiovascular diagnostic technique. Left atrial (LA) size, as measured by transthoracic echocardiography (TTE), is associated with cardiovascular disease and is a risk factor for atrial fibrillation, stroke, death, and the success of cardioversion. Assessment of LA size has not been as well validated on TEE as on TTE. We determined LA size measurements in four standard views in 122 patients undergoing TEE and TTE at the same setting. In this study, we found that measurement of LA dimensions by TEE suffers from significant limitations in all views except the basal long‐axis view (mid‐esophageal level) with transducer plane at 120–150 degrees. This view had the best correlation with transthoracic LA measurements: r = 0.79 for TEE long axis (CI 0.71–0.85), P <.0001. (ECHOCARDIOGRAPHY, Volume 22, November 2005)