JEJan Emmerechts

Jan Emmerechts

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jan Emmerechts has a total of 46 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Implementation of a patient blood management optimization flowchart for preoperative anemia using automated alerts: An 8‐month follow‐up

    by Bas Calcoen, Morane Swennen, Birgit Loveniers, Ann‐Marie Matthys, Tom Vauterin, Jan Van Droogenbroeck, Helena Devos, Jan Emmerechts, Barbara Cauwelier

    Background and Objectives: Preoperative anemia (PA) and thrombocytopenia (PT) are associated with increased perioperative morbidity and mortality. We implemented an automated flowchart integrating automated diagnostic reflex testing with electronic notifications to the preoperative unit (POU) triggered by hemoglobin (Hb) concentration 9 /L. Materials and Methods: In this retrospective observational study, compliance and management of PA and PT were evaluated after routine implementation of the flowchart. Results: The flowchart was initiated for 41 patients (1.5% of POU orders). Hb was 8–10 g/dL in 34 patients and <8 g/dL in four patients. Three patients had PLT 10 g/dL. At least one recommended action was undertaken in 88%, most frequently including documentation in the electronic medical record, communication with treating clinicians or referral to a hematologist. Etiology was established in 25 patients, with isolated iron deficiency as the most common cause of PA. Preoperative correction of anemia was performed in 26/41 patients and was primarily non‐transfusion‐based. Seven patients received transfusion therapy. Surgery was postponed in one case. Conclusion: A high compliance with the automated flowchart was observed and guided diagnostic and therapeutic interventions. Further optimization may improve standardized perioperative management of PA and PT.

  • Optimizing Anemia Diagnosis: Clinical Evaluation of an Automated, Diagnostic Anemia Protocol

    by Morane Swennen, Barbara Cauwelier, Helena Devos, Alexander Schauwvlieghe, Jan van Droogenbroeck, Sylvia Snauwaert, Tom Lodewyck, Jan Emmerechts

  • Evaluation of AQUIOS STEM, a novel method for automated CD34+ stem cell enumeration using flow cytometry

    by Kim Callebaut, Eva Gijbels, Jonathan Vanbesien, Dries Deeren, Jan Van Droogenbroeck, Jan Emmerechts, Elisabeth Moreau

    Objectives: Hematopoietic stem cell transplantation (HSCT) is a potentially curative treatment for various diseases. The measurement of CD34+ cells is crucial to schedule the peripheral blood stem cell collection and assess the engraftment potential of the apheresis product. The AQUIOS STEM system has been introduced as a novel application on the AQUIOS CL, a fully automated flow cytometer, for the enumeration of CD34+ hematopoietic progenitor cells (HPCs) in accordance with the The International Society for Hematotherapy and Graft Engineering guidelines. This study aimed to assess the potential of the novel AQUIOS STEM system versus currently used systems including the FACSCanto‐II and the FACS Lyric flow cytometer in a multicenter study.Methods: A total of 91 samples were used for the validation of the AQUOIS STEM system, including an analytical performance evaluation by means of assessing precision, sample stability, intersample carryover, and linearity and a method comparison with the present FACS systems in use to assess analytical and clinical decision agreement.Results: Results showed excellent precision, with coefficient of variations <15% for dedicated quality control material and patient samples. There was no significant carry over. The fresh apheresis samples were stable when stored overnight at room temperature and at 4°C. Analytical comparison with the current systems demonstrated good correlation in peripheral blood, and minimal, clinically neglectable systematic and proportional bias in fresh apheresis products but a low correlation coefficient in cryopreserved products.Conclusions: The STEM system on AQUIOS CL allows automated enumeration of CD34+ stem cells, demonstrating good analytical performance and promising overall outcomes in peripheral blood and fresh apheresis products.

  • Acquired factor X deficiency in a multiple myeloma without amyloidosis: a case report

    by Amber Coussee, Gudrun Alliet, Anne-Sophie Hervent, Liesbeth Vynckier, Jan Emmerechts, Sam Van Hecke, Lies Persijn

    Multiple myeloma is one of the most common hematologic malignancies. Acquired factor X deficiencies are often observed in primary (AL) amyloidosis and rarely in multiple myeloma. We report a case of an acquired factor X deficiency in a patient with a newly diagnosed IgA lambda multiple myeloma, without any evidence of concomitant amyloidosis. We present the patient's medical history, clinical and physical examinations, laboratory analysis, and outcome. A 76-year-old male presented at the emergency department with ongoing gingival bleeding. Several analytical problems with blood sample analysis arose, which eventually led to the diagnosis of a multiple myeloma. Further exploration revealed an acquired factor X deficiency, explaining the ongoing bleeding. There was no evidence of concomitant amyloidosis. The multiple myeloma was treated, leading to complete remission of the malignancy and bleeding tendency. While coagulopathy is rarely observed in patients diagnosed with multiple myeloma, considering an acquired factor X deficiency becomes relevant when such patient present with bleeding diathesis.


  • Evaluation of the CellaVision DM96 advanced RBC application for screening and follow-up of malaria infection

    by Lisa Florin, Karel Maelegheer, Astrid Muyldermans, Marjan Van Esbroeck, Eric Nulens, Jan Emmerechts


  • Evaluation of two automated cell counters for the analysis of hematopoietic progenitor cell apheresis products

    by S. Gils, B. Cauwelier, H. Devos, I. Vanlaere, S. Roggeman, J. Emmerechts

    Summary: Introduction: Routine hematology parameters in hematopoietic progenitor cell apheresis products (HPC‐A) are usually determined using automated cell counters. These instruments, however, are designed to analyze whole blood samples, that differ considerably from HPC‐A in blood cell composition. This study evaluates the performance of two automated cell counters for the analysis of HPC‐A.Methods: Routine hematology parameters [red blood cells (RBC), hematocrit (HCT), mean corpuscular volume (MCV), white blood cells (WBC), WBC differentiation, and platelets (PLT)] were determined on the Unicel DxH 800 instrument (Beckman Coulter) and the XN‐350 instrument (Sysmex). Correlations with the reference methods, intrarun precision, and linearity of the analyses were studied.Results: Good correlations were found for almost all parameters. However, RBC count was overestimated by XN‐350, using the impedance technique, as was neutrophil percentage using DxH 800. Coefficients of variation for intrarun precision were below 10% on both analyzers for all parameters, except for neutrophil percentage (14.7%) and PLT (10%) on DxH 800. Both instruments showed good linearity for all parameters, except for RBC and HCT on DxH 800.Conclusion: With the exception of the measurement of neutrophils on DxH 800 and RBC by the impedance technique on the XN‐350, routine hematology parameters in HPC‐A can safely be determined using automated cell counters.


  • Evaluation of the Red Blood Cell Advanced Software Application on the CellaVision DM96

    by M. Criel, M. Godefroid, B. Deckers, H. Devos, B. Cauwelier, J. Emmerechts

    Summary: Introduction: The CellaVision Advanced Red Blood Cell (RBC) Software Application is a new software for advanced morphological analysis of RBCs on a digital microscopy system. Upon automated precharacterization into 21 categories, the software offers the possibility of reclassification of RBCs by the operator. We aimed to define the optimal cut‐off to detect morphological RBC abnormalities and to evaluate the precharacterization performance of this software.Methods: Thirty‐eight blood samples of healthy donors and sixty‐eight samples of hospitalized patients were analyzed. Different methodologies to define a cut‐off between negativity and positivity were used. Sensitivity and specificity were calculated according to these different cut‐offs using the manual microscopic method as the gold standard. Imprecision was assessed by measuring analytical within‐run and between‐run variability and by measuring between‐observer variability.Results: By optimizing the cut‐off between negativity and positivity, sensitivities exceeded 80% for ‘critical’ RBC categories (target cells, tear drop cells, spherocytes, sickle cells, and parasites), while specificities exceeded 80% for the other RBC morphological categories. Results of within‐run, between‐run, and between‐observer variabilities were all clinically acceptable.Conclusion: The CellaVision Advanced RBC Software Application is an easy‐to‐use software that helps to detect most RBC morphological abnormalities in a sensitive and specific way without increasing work load, provided the proper cut‐offs are chosen. However, evaluation of the images by an experienced observer remains necessary.


  • Evaluation of schistocyte analysis by a novel automated digital cell morphology application

    by A.‐S. Hervent, M. Godefroid, B. Cauwelier, J. Billiet, J. Emmerechts

    Summary: Introduction: The CellaVision Advanced Red Blood Cell (RBC) Software Application is a new software for advanced morphological analysis of RBC, which automatically performs a preliminary characterization and grouping of RBC into 21 morphological categories, including schistocytes. Upon automated classification, the software offers the possibility of reclassification of RBC by the operator. The aim of this study was to evaluate the schistocyte analysis by the CellaVision Advanced RBC Application.Methods: Schistocyte counts were evaluated comparing the automated count on a CellaVision DM96, both before and after reclassification, with the reference manual microscopic method according to the ICSH criteria. Thirty‐six samples of hospitalized patients and 40 samples of controls were analyzed.Results: Within‐run, between‐run and between‐observer coefficients of variation were lower when counted with the CellaVision compared to the manual microscopic count. The very high sensitivity but rather poor specificity implicates the need for reclassification by the operator, following automated analysis. After reclassification, method comparison studies revealed good agreement with the manual microscopic method, with however slightly higher values of schistocytes for the automated analysis.Conclusion: The CellaVision Advanced RBC Software Application provides a sensitive and reproducible measurement of schistocytes in peripheral blood, but still requires manual revision. Furthermore, it is an easy‐to‐use software and an excellent teaching tool that might contribute to standardization in the investigation of schistocyte‐related conditions.


  • Acquired thrombin and FV inhibitors upon aortic bioprosthetic valve replacement

    by A.‐S. Hervent, M. Schepens, M. Bourgeois, J. Emmerechts

  • OXIDIZED-LDL AND CARBON LOAD OF LUNG MACROPHAGES

    by Lotte Jacobs, Jan Emmerechts, Marc Hoylaerts, Chantal Mathieu, Peter Hoet, Benoit Nemery, Tim Nawrot

    Environmental Health Perspectives is an Open Access journal published by the National Institute of Environmental Health Sciences. Environmental Health Perspectives is an Open Access journal published by the National Institute of Environmental Health Sciences.