Mingxiang Luo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mingxiang Luo has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Meng Yin
Guangdong Provincial Key Lab of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
2 shared publications - Wujing Cao
Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
2 shared publications Hongliu Yu
University of Shanghai for Science and Technology
1 shared publication- Jinke Li
Guangdong Provincial Key Laboratory of Robotics and Intelligent System, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
1 shared publication - Kui Xiang
School of Automation, Wuhan University of Technology, Wuhan 430070, China
1 shared publication - Lijun Yang
School of Automation, Wuhan University of Technology, Wuhan, China
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 6, 0250
Lateral Walking Gait Recognition and Hip Angle Prediction Using a Dual-Task Learning Framework
Lateral walking exercise is beneficial for the hip abductor enhancement. Accurate gait recognition and continuous hip joint angle prediction are essential for the control of exoskeletons. We propose a dual-task learning framework, the “Twin Brother” model, which fuses convolutional neural network (CNN), long short-term memory (LSTM), neural networks (NNs), and the squeezing-elicited attention mechanism to classify the lateral gait stage and estimate the hip angle from electromyography (EMG) signals. The EMG signals of 6 muscles from 10 subjects during lateral walking were collected. Four gait phases were recognized, and the hip angles of both legs were continuously estimated. The sliding window length of 250 ms and the sliding increment of 3 ms were determined by the requirements of response time and recognition accuracy of the real-time system. We compared the performance of CNN-LSTM, CNN, LSTM, support vector machine, NN, K-nearest neighbor, and the “Twin Brother” models. The “Twin Brother” model achieved a recognition accuracy (mean ± SD) of 98.81% ± 0.14%. The model’s predicted root mean square error (RMSE) for the left and right hip angles are 0.9183° ± 0.024° and 1.0511° ± 0.027°, respectively, where the R 2 are 0.9853 ± 0.006 and 0.9808 ± 0.008. The accuracy of recognition and estimation are both better than comparative models. For gait phase percentage prediction, RMSE and R 2 predicted by the model can reach 0.152° ± 0.014° and 0.986 ± 0.011, respectively. These results demonstrate that the method can be applied to lateral walking gait recognition and hip joint angle prediction.
- 1 January 2025
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 6, 0250
Open AccessLateral Walking Gait Recognition and Hip Angle Prediction Using a Dual-Task Learning Framework
Lateral walking exercise is beneficial for the hip abductor enhancement. Accurate gait recognition and continuous hip joint angle prediction are essential for the control of exoskeletons. We propose a dual-task learning framework, the “Twin Brother” model, which fuses convolutional neural network (CNN), long short-term memory (LSTM), neural networks (NNs), and the squeezing-elicited attention mechanism to classify the lateral gait stage and estimate the hip angle from electromyography (EMG) signals. The EMG signals of 6 muscles from 10 subjects during lateral walking were collected. Four gait phases were recognized, and the hip angles of both legs were continuously estimated. The sliding window length of 250 ms and the sliding increment of 3 ms were determined by the requirements of response time and recognition accuracy of the real-time system. We compared the performance of CNN-LSTM, CNN, LSTM, support vector machine, NN, K-nearest neighbor, and the “Twin Brother” models. The “Twin Brother” model achieved a recognition accuracy (mean ± SD) of 98.81% ± 0.14%. The model’s predicted root mean square error (RMSE) for the left and right hip angles are 0.9183° ± 0.024° and 1.0511° ± 0.027°, respectively, where the R 2 are 0.9853 ± 0.006 and 0.9808 ± 0.008. The accuracy of recognition and estimation are both better than comparative models. For gait phase percentage prediction, RMSE and R 2 predicted by the model can reach 0.152° ± 0.014° and 0.986 ± 0.011, respectively. These results demonstrate that the method can be applied to lateral walking gait recognition and hip joint angle prediction.
- 13 October 2023
- Published by Springer Nature
- p. 111-120
An Autoencoder-Based Feature Extraction Method Applied to the Detection of Lateral Walking Gait Phase
- 13 October 2023
- Published by Springer Nature
- p. 111-120
An Autoencoder-Based Feature Extraction Method Applied to the Detection of Lateral Walking Gait Phase