EBEmel Bulut

Emel Bulut

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Emel Bulut has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effectiveness of Fan-Shaped Buccal Kinesio Taping in Third Molar Surgery: A Split-Mouth Randomized Controlled Trial

    by Nigar Novruzova, Emel Bulut, Emine Asena Singer

    Objective: Kinesio taping (KT) has been proposed as an adjunct to standard care for managing postoperative complications following impacted mandibular third molar surgery. This study aimed to evaluate the effectiveness of KT in improving postoperative outcomes.Methods: This prospective, split-mouth, controlled clinical study included 25 healthy adults (18–35 years) requiring bilateral mandibular third molar removal, with surgeries performed at least four weeks apart. The experimental group received KT postoperatively, applied fan-shaped to the buccal region for five days, while the control group received standard care. Swelling, pain, and trismus were measured preoperatively and on postoperative days 2 and 7, while bleeding was assessed on day 1.Results: Swelling peaked on day 2 and subsided by day 7 in both groups, with no significant differences (P>.05). Pain decreased over time without statistical significance (P>.05). Trismus recovery was slower in the KT group but not significant. Bleeding scores were similar (P=.61). Additionally, 56% found KT impractical, and 8% reported significant discomfort.Conclusion: KT did not provide statistically significant benefits in reducing postoperative complications compared to standard care. While KT is safe and well-tolerated, its clinical utility remains limited. Further research is necessary to refine application techniques and assess their broader clinical impact.Keywords: Impacted tooth, kinesio tape, oral surgery, pain management, postoperative swelling

  • Comparative clinical effects of extraoral photobiomodulation using laser and LED on pain, swelling, and quality of life following impacted mandibular third molar surgery: a randomized split-mouth trial

    by Duygu Albayrak, Emel Bulut, Emine Asena Singer

    This study aimed to compare the clinical effectiveness of extraoral photobiomodulation using laser and light-emitting diode (LED) in reducing postoperative pain, swelling, and improving oral health-related quality of life following impacted mandibular third molar surgery. This randomized, split-mouth clinical trial included 72 patients with bilaterally symmetrical impacted mandibular third molars. Participants were allocated into three groups: low-level laser therapy (LLLT), LED, and LLLT-LED. Each patient received PBM treatment on one side and served as their own control. LLLT (810 nm GaAlAs diode laser) and LED (618 nm OsseoPulse) were applied extraorally on postoperative days 0, 2, and 7. Pain was assessed using a visual analog scale (VAS) at 4h and daily up to day 7. Swelling was measured via standardized facial distances at baseline, day 2, and day 7. Quality of life was evaluated using the OHIP-14 questionnaire preoperatively and on day 7. LED therapy significantly reduced pain at the 4th hour and on postoperative days 3 to 6 (p < 0.05). Regarding postoperative swelling, a significant difference was observed only in the LLLT-LED group, where the LED-treated side showed greater overall swelling reduction from preoperative to postoperative day 7 (p < 0.05). Quality-of-life scores improved in both groups, with more domains showing significant change in the LLLT group (10 vs. 7). LED was more effective for early postoperative pain control and showed greater late-phase swelling reduction in the side-to-side comparison. Quality-of-life scores improved in both groups, with a larger number of significantly improved domains in the LLLT group.

  • Evaluation of the Zygomaticofacial Foramen Through Computed and Cone Beam Computed Tomography Imaging

    by Furkan Aksoy, Tuna Sumer, Eda E. Esen, Aslı Tanrivermis Sayit, Emel Bulut

    Purpose: The zygomaticofacial foramen (ZFF) serves as a critical anatomical landmark in zygomatic implant surgery and facial flap procedures. This study aimed to compare the effectiveness of computed tomography (CT) and cone-beam computed tomography (CBCT) in visualizing the ZFF, and to determine which imaging modality provides greater reliability for clinical and surgical planning. Methods: A total of 100 CT and 100 CBCT scans were retrospectively analyzed, providing radiological data from 400 zygomatic bones. The number and location of ZFFs were assessed by 2 independent observers. The relationship between ZFF number and variables such as side, sex, and age was statistically analyzed. Results: Computed tomography and CBCT detected a comparable number of foramina (270 and 267, respectively), with no statistically significant difference between the modalities ( P > 0.05). A significant correlation between right and left sides was observed (r = 0.672, P < 0.001), indicating a tendency for bilateral symmetry. The most common finding was the presence of a single foramen (48%), followed by 2 foramina (31.2%). Females exhibited a significantly greater number of foramina than males ( P = 0.012), whereas age showed no significant correlation. Conclusion: Both CT and CBCT provide comparable accuracy in detecting the ZFF. This finding is clinically significant as it provides an evidence-based rationale for selecting CBCT, a modality with a lower radiation dose and reduced cost, for preoperative evaluation. These results confirm that clinicians can confidently use CBCT for individualized, imaging-based surgical planning to minimize neurovascular complications without sacrificing diagnostic reliability.

  • Effectiveness of Flipped Learning Compared to Conventional Instruction in Teaching Tooth Extraction to Dental Students

    by Emine Asena Singer, Emrecan Ertaş, Emel Bulut, Gülşen Demir, Oğuzhan Koca, Ahmet Yaşarsoy

    Objectives: This study aimed to compare the effectiveness of conventional theoretical instruction and flipped learning supported by demonstrative videos in teaching tooth extraction to dental students. Methods: A prospective, comparative study was conducted during the 2024–2025 academic year with 112 fourth‐year dental students who had no prior experience in tooth extraction. Students were randomized into a flipped learning group ( n = 62) and a control group ( n = 50). The flipped group received video‐based procedural education, while the control group received conventional lectures. Following their first clinical extraction, all students completed a seven‐item questionnaire assessing unaided performance, anxiety, preparedness, and perceived competence. Statistical analyses included Chi‐square and Mann–Whitney U tests, with effect sizes reported as rank biserial correlation ( r ). Results: A significantly greater proportion of students in the flipped group performed the extraction without assistance compared to the control group (58.1% vs. 36.0%, p = 0.0468). The flipped group also reported lower procedural anxiety ( p = 0.0468, r = 0.21) and greater perceived sufficiency of instrument training ( p = 0.0224, r = 0.24). However, no significant group differences were observed in perceived usefulness of instruction, theoretical preparation, or self‐rated instrument competence. Conclusions: Flipped learning improved students’ procedural independence and reduced anxiety during their first clinical extraction. While beneficial for technical and emotional preparedness, flipped instruction alone may not sufficiently enhance students’ self‐perceived competence or theoretical readiness. These findings support incorporating flipped learning into dental curricula while highlighting the need for complementary strategies to foster clinical confidence


  • Open Access

    Odontojenik Keratokistlerde Farklı Tedavi Yaklaşımları ve Takip Sonuçlarının Retrospektif Olarak Değerlendirilmesi

    by Kübra Uğurlu, Nilüfer Özkan, Emel Bulut

    Amaç: Odontojenik keratokistler (OKK); lokal agresif özellikleri ve yüksek nüks etme oranları ile karakterize odontojenik kistlerdir. Bu çalışmada; OKK’lerin demografik özellikleri, tedavi sonuçları ve nüks oranlarının incelenmesi hedeflenmektedir. Gereç ve Yöntem: Bu çalışma; Ondokuz Mayıs Üniversitesi Diş Hekimliği Fakültesi Ağız, Diş ve Çene Cerrahisi Anabilim Dalı’nda yürütülmüştür. Çalışmaya OKK tanısı konulan 19 hasta dahil edilmiştir. Hastaların; yaş, cinsiyet, lezyonun lokalizasyonu, uygulanan cerrahi tedavi yöntemleri, nüks varlığı ve takip süreleri retrospektif olarak incelenmiştir. Bulgular: İncelenen hastaların yaş aralığı 8-79 yıl aralığında olup ortalama yaşları 38,7’dir. 19 hastanın 14’ü kadın, 5’i ise erkektir. İncelenen 20 lezyondan 11’i multiloküler, 9’u ise uniloküler radyografik görünümdedir. Lezyonların 18’i mandibular posterior bölgede tespit edilmiştir. Tedavi yöntemleri olarak enükleasyon ve küretaj öne çıkmış, bazı vakalarda ise lezyon boyutlarının küçültülmesi amacıyla dekompresyon tedavisine başvurulmuştur. Tedavisi tamamlanan 16 hastanın 3’ünde nüks geliştiği tespit edilmiştir. Takip süreleri 5 ila 120 ay arasında değişkenlik göstermektedir. Sonuç: Odontojenik keratokistlerin tedavisinde kullanılan yöntemlerin dikkatle seçilmesi ve hastaların uzun süreli klinik ve radyografik olarak takip edilmesi, tedavi başarısı üzerinde önemli bir etkiye sahiptir.

  • A New Material For Detecting Submerged Implants: An Animal Experiment

    by Eren Yilmaz, Emel Bulut, Nilüfer Kuruca, Tolga Güvenç

    Objective: There are difficulties in determining the location of submerged implants when cover screws and healing screws are to be replaced. Because of this, a new implant cover screw has been designed. The purpose of this study was to investigate the properties of a novel implant cover screws in rabbits. Methods: 10 New Zealand White rabbits were randomly divided into two groups. Diastema regions behind the incisor teeth were used for the placement of cover screws. In the control group, the screws (n=20) that received no processing were placed whereas, in the experimental group, the screws (n=20) that top surfaces were coated with europium and dysprosium doped strontium aluminate were placed to the diastema regions. Animals were sacrificed after 6 weeks. Dental LED curing light was applied to the oral mucosa regions in which screws were placed in the experimental group just after sacrification and the visibility of the screws was evaluated. To determine the biocompatibility of the coated screws, oral mucosas which contacted with the screws, livers and kidneys were removed and examined histopathologically. Results: After light application, only the screws in the upper jaws of the experimental group became visible (n=10). Histopathological examinations performed on the kidneys, livers and oral mucosa tissues which contacted with the screws. There were no significant differences between the experimental and control groups regarding these tissues. Conclusion: According to the results of this study, it can be concluded that the titanium implant cover screws coated with europium and dysprosium doped strontium aluminate were biocompatible for rabbits.


  • Open Access

    Comparison of the planimetry and point-counting methods for the assessment of the size of the mandible cysts on orthopantomograms

    by E. Bulut, B. Sahin, M. Muglali, B. Bekcioglu

    Objective: The purpose of this study is to compare the computer-assisted planimetry and point-counting methods in evaluating the sizes of the mandibular cysts with respect to their agreement and the time required to analyze. Study Design: The surface areas of 46 mandibular cyst lesions on orthopantomograms were estimated using the point-counting and computer-assisted planimetry methods. Three observers evaluated the outlined areas twice, using the point-counting (PC) and computer-assisted planimetry (CAP) methods with an interval of two weeks. In the planimetry technique, digitalized images and ImageJ software were used to measure the surface area of the half mandibles and cysts. The grids were superimposed over the same images and the number of points hitting the interested structures was counted for the point-counting technique. The projection area fraction (PAF) of the cysts within the mandible was estimated using the obtained values by means of the two techniques. Intraclass correlation coefficient was used to assess the level of agreement between the two methods. Inter-rater reliability analysis using the Kappa statistic was performed to determine consistency among raters. Results: CAP and PC techniques showed consistent intra-observer values in all observers. Intraclass correlation between CAP and PC measurements of first, second and third observers were found to be 0.9986, 0.9988 and 0.9994 respectively. The durations of PC technique was 32% higher than the CAP technique. Conclusion: PC and CAP methods were seemed to show sufficient agreement to be used interchangeably. The main disadvantage of the PC analysis is it takes more time than CAP method.