Bernhard Zrenner
Bernhard Zrenner has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
J. Schreieck
2 shared publications- Julinda Mehilli
Medizinische Klinik I, Lakumed Hospital Landshut-Achdorf, Medical Campus Lower Bavaria, University of Regensburg , Landshut
2 shared publications - Michael A. E. Schneider
Deutsches Herzzentrum and I. Medizinische Klinik, Technische Universität München, Munich, Germany
2 shared publications - Adnan Kastrati
Deutsches Herzzentrum München
1 shared publication Albert Schömig
Deutsches Herzzentrum München and Medizinische Klinik, Klinikum rechts der Isar, Technische Universität München, Munich, Germany
1 shared publication- Anna Lena Lahmann
Deutsches Herzzentrum München, Technische Universität München , Munich, Germany
1 shared publication
Latest Publications
- Open Access
- 5 October 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (10)
Use of a taurolidine containing antimicrobial wash to reduce cardiac implantable electronic device infection
TauroPace (Tauropharm, Bavaria Germany), a taurolidine solution for combating cardiac implantable electronic device (CIED) infection, was compared with a historical control of 3% hydrogen peroxide (H2O2) in a prospective observational study. The device pocket was irrigated, and all hardware accessible within (leads, suture sleeves, pulse generator) was wiped with H2O2, TauroPace, or taurolidine in a galenic formulation during any invasive CIED procedure at the study centre. Only CIED procedures covered by TauroPace or H2O2 from 1 January 2017 to 28 February 2022 were included for analysis. Patients who underwent >1 procedure were censored for the last treatment group and reassigned at the next procedure. The primary endpoint was major CIED infection within 3 months. The secondary endpoints were CIED infection beyond 3 months, adverse events potentially related to the antimicrobial solutions, CIED system, procedure, and death, till the end of follow-up. TauroPace covered 654 procedures on 631 patients, and H2O2 covered 551 procedures on 532 patients. The TauroPace group had more patient risk factors for infection than the H2O2 group (P = 0.0058) but similar device and procedure-specific risk factors (P = 0.17). Cardiac implantable electronic device infection occurred in 0/654 (0%) of the TauroPace group and 6/551 (1.1%) of the H2O2 group (P = 0.0075). Death occurred in 23/654 (3.5%) of the TauroPace group and 14/551 (2.5%) of the H2O2 group (P = 0.33). Non-infection related adverse events were rarer in the TauroPace (3.8%) than the H2O2 (6.0%) group (P = 0.0802). TauroPace is safe but more effective than H2O2 in reducing CIED infection. ClinicalTrials.gov Identifier: NCT05576194
- 5 October 2023
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 25 (10)
Open AccessUse of a taurolidine containing antimicrobial wash to reduce cardiac implantable electronic device infection
TauroPace (Tauropharm, Bavaria Germany), a taurolidine solution for combating cardiac implantable electronic device (CIED) infection, was compared with a historical control of 3% hydrogen peroxide (H2O2) in a prospective observational study. The device pocket was irrigated, and all hardware accessible within (leads, suture sleeves, pulse generator) was wiped with H2O2, TauroPace, or taurolidine in a galenic formulation during any invasive CIED procedure at the study centre. Only CIED procedures covered by TauroPace or H2O2 from 1 January 2017 to 28 February 2022 were included for analysis. Patients who underwent >1 procedure were censored for the last treatment group and reassigned at the next procedure. The primary endpoint was major CIED infection within 3 months. The secondary endpoints were CIED infection beyond 3 months, adverse events potentially related to the antimicrobial solutions, CIED system, procedure, and death, till the end of follow-up. TauroPace covered 654 procedures on 631 patients, and H2O2 covered 551 procedures on 532 patients. The TauroPace group had more patient risk factors for infection than the H2O2 group (P = 0.0058) but similar device and procedure-specific risk factors (P = 0.17). Cardiac implantable electronic device infection occurred in 0/654 (0%) of the TauroPace group and 6/551 (1.1%) of the H2O2 group (P = 0.0075). Death occurred in 23/654 (3.5%) of the TauroPace group and 14/551 (2.5%) of the H2O2 group (P = 0.33). Non-infection related adverse events were rarer in the TauroPace (3.8%) than the H2O2 (6.0%) group (P = 0.0802). TauroPace is safe but more effective than H2O2 in reducing CIED infection. ClinicalTrials.gov Identifier: NCT05576194
- 7 November 2017
- Published by Georg Thieme Verlag KG in Thrombosis and Haemostasis
- Vol. 117 (10) , 1989-1999
Validation of the DAPT score in patients randomized to 6 or 12 months clopidogrel after predominantly second-generation drug-eluting stents
The DAPT score is a recently-proposed decision tool for guiding optimal duration of dual antiplatelet therapy (DAPT). It showed modest accuracy in prior derivation and validation cohorts of patients with ≥12 months DAPT. This study was aimed to evaluate the validity of the DAPT score in a cohort of patients with 6 or 12 months DAPT after implantation of predominantly second-generation drug-eluting stents. We analyzed data of patients enrolled in the ISAR-SAFE trial. Patients were classified into low (<2) or high (≥2) DAPT score groups. Primary ischaemic (all-cause death, myocardial infarction, definite stent thrombosis or stroke) and bleeding (TIMI major or minor) outcomes were analyzed in the low and high DAPT score groups. Data of 3976 patients were available for DAPT score calculation. 2407 patients (60.5%) were classified in the low DAPT score group and 1569 patients (39.5%) in the high DAPT score group. In the low DAPT score group there were no significant differences between 6 and 12 months DAPT regarding ischaemic (1.0% vs. 1.4%, HR=0.74, 95% CI, 0.35–1.57; p=0.43) or bleeding outcomes (0.3% vs. 0.8%, HR=0.44, 95% CI, 0.13–1.42; p=0.17). In the high DAPT score group there were also no significant differences between 6 and 12 months DAPT regarding ischaemic (1.9% vs. 1.8%, HR=1.02, 95% CI, 0.49–2.14; p=0.96) or bleeding (0.3% vs. 0.5%, HR=0.51, 95% CI, 0.09–2.78; p=0.44) outcomes. In conclusion, the DAPT score failed to show a differential treatment effect in patients receiving 6 or 12 months DAPT after contemporary drug-eluting stent implantation.
- 7 November 2017
- Published by Georg Thieme Verlag KG in Thrombosis and Haemostasis
- Vol. 117 (10) , 1989-1999
Validation of the DAPT score in patients randomized to 6 or 12 months clopidogrel after predominantly second-generation drug-eluting stents
The DAPT score is a recently-proposed decision tool for guiding optimal duration of dual antiplatelet therapy (DAPT). It showed modest accuracy in prior derivation and validation cohorts of patients with ≥12 months DAPT. This study was aimed to evaluate the validity of the DAPT score in a cohort of patients with 6 or 12 months DAPT after implantation of predominantly second-generation drug-eluting stents. We analyzed data of patients enrolled in the ISAR-SAFE trial. Patients were classified into low (<2) or high (≥2) DAPT score groups. Primary ischaemic (all-cause death, myocardial infarction, definite stent thrombosis or stroke) and bleeding (TIMI major or minor) outcomes were analyzed in the low and high DAPT score groups. Data of 3976 patients were available for DAPT score calculation. 2407 patients (60.5%) were classified in the low DAPT score group and 1569 patients (39.5%) in the high DAPT score group. In the low DAPT score group there were no significant differences between 6 and 12 months DAPT regarding ischaemic (1.0% vs. 1.4%, HR=0.74, 95% CI, 0.35–1.57; p=0.43) or bleeding outcomes (0.3% vs. 0.8%, HR=0.44, 95% CI, 0.13–1.42; p=0.17). In the high DAPT score group there were also no significant differences between 6 and 12 months DAPT regarding ischaemic (1.9% vs. 1.8%, HR=1.02, 95% CI, 0.49–2.14; p=0.96) or bleeding (0.3% vs. 0.5%, HR=0.51, 95% CI, 0.09–2.78; p=0.44) outcomes. In conclusion, the DAPT score failed to show a differential treatment effect in patients receiving 6 or 12 months DAPT after contemporary drug-eluting stent implantation.
- Open Access
- 25 March 2011
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (8) , 975-983
Reduction of Right Ventricular Pacing with Advanced Atrioventricular Search Hysteresis: Results of the PREVENT Study
Right ventricular pacing predisposes to the development of heart failure and atrial fibrillation. Automatic atrioventricular search hysteresis (AVSH) is a commonly used strategy to decrease the percentage of right ventricular pacing (%VP) in patients without permanent AV block, but the results have not been optimal. The randomized, crossover PREVENT study evaluated whether an enhanced AVSH with two new features can reduce %VP compared with standard AVSH. The new features are the repetitive hysteresis [switch from extended to basic AV delay after a consistent loss of intrinsic AV conduction (IAVC) lasting for six consecutive atrial cycles] and the scan hysteresis (periodic IAVC search extension over six consecutive atrial cycles). Both standard AVSH and enhanced AVSH performed a periodic IAVC search every 180 cardiac cycles and operated with a basic AV-delay of 225 ms and a rate-independent maximum AV-delay of 300 ms for paced and sensed atrial events. Among 178 patients, 53.4% had no evidence of AV block at enrollment and 46.6% had history of intermittent AV block. The median %VP was decreased by enhanced AVSH compared to standard AVSH (4.0% vs 5.5%, P < 0.001), particularly in patients with a history of AV block (21.4% vs 25.5%, P < 0.001). The primary study hypothesis that 25% of all patients would experience > 20% relative %VP reduction was not met as 46 (25.8%) patients (95% confidence interval, 20.5-31.8%) presented such relative reduction. The enhanced AVSH algorithm reduces %VP compared with standard AVSH in patients with intermittent AV block.
- 25 March 2011
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 34 (8) , 975-983
Open AccessReduction of Right Ventricular Pacing with Advanced Atrioventricular Search Hysteresis: Results of the PREVENT Study
Right ventricular pacing predisposes to the development of heart failure and atrial fibrillation. Automatic atrioventricular search hysteresis (AVSH) is a commonly used strategy to decrease the percentage of right ventricular pacing (%VP) in patients without permanent AV block, but the results have not been optimal. The randomized, crossover PREVENT study evaluated whether an enhanced AVSH with two new features can reduce %VP compared with standard AVSH. The new features are the repetitive hysteresis [switch from extended to basic AV delay after a consistent loss of intrinsic AV conduction (IAVC) lasting for six consecutive atrial cycles] and the scan hysteresis (periodic IAVC search extension over six consecutive atrial cycles). Both standard AVSH and enhanced AVSH performed a periodic IAVC search every 180 cardiac cycles and operated with a basic AV-delay of 225 ms and a rate-independent maximum AV-delay of 300 ms for paced and sensed atrial events. Among 178 patients, 53.4% had no evidence of AV block at enrollment and 46.6% had history of intermittent AV block. The median %VP was decreased by enhanced AVSH compared to standard AVSH (4.0% vs 5.5%, P < 0.001), particularly in patients with a history of AV block (21.4% vs 25.5%, P < 0.001). The primary study hypothesis that 25% of all patients would experience > 20% relative %VP reduction was not met as 46 (25.8%) patients (95% confidence interval, 20.5-31.8%) presented such relative reduction. The enhanced AVSH algorithm reduces %VP compared with standard AVSH in patients with intermittent AV block.
- 13 January 2008
- Published by Springer Nature in Der Kardiologe
- Vol. 2 (1) , 49-64
Curriculum „Praxis der ICD-Therapie“
- 13 January 2008
- Published by Springer Nature in Der Kardiologe
- Vol. 2 (1) , 49-64
Curriculum „Praxis der ICD-Therapie“
- Open Access
- 1 December 2003
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 4 (Supplement) , B12
A08-3 Circumferential mapping and electric isolation of pulmonary veins in patients with atrial fibrillation: mid term follow-up results
- 1 December 2003
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 4 (Supplement) , B12
Open AccessA08-3 Circumferential mapping and electric isolation of pulmonary veins in patients with atrial fibrillation: mid term follow-up results