Jianxi Ding
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jianxi Ding has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Jianchao Zhao
Center for Offshore Engineering and Safety Technology, China University of Petroleum (East China), Qingdao, China
8 shared publications - Qinyu Chen
Shandong Key Laboratory of Design and Manufacturing for High-End Offshore Oil and Gas Equipment, China University of Petroleum (East China), Qingdao 266580, China, and also with the College of Mechanical and Electronic Engineering, China University of Petroleum (East China), Qingdao, China
8 shared publications - Wei Li
School of Mechanical and Electrical Engineering, China University of Petroleum (East China), Qingdao, China
8 shared publications - Xiaokang Yin
School of Mechanical and Electrical Engineering, China University of Petroleum (East China), Qingdao, China
6 shared publications - Xin’aN Yuan
School of Mechanical and Electrical Engineering, China University of Petroleum (East China), Qingdao, China
6 shared publications - Dong Hu
College of Mechanical and Electronic Engineering, Shandong Key Laboratory of Design and Manufacturing for High-end Offshore Oil and Gas Equipment, China University of Petroleum (East China), Qingdao, China
4 shared publications
Latest Publications
- 13 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-14
Physics-Informed Neural Network for Real-Time Imaging and Evaluation of Defect Based on High-Definition ACFM Probe
Defects reduce the bearing capacity of underwater structures. The determination of defect size provides guidance for underwater structure safety assessment and maintenance. Alternating current field measurement technique is widely used in underwater structure detection for the advantages of non-contact detection and quantitative ability of defects. Generally, the calibration and physical mechanism inversion methods are proposed to evaluate dimensions of defects with a lot of assumptions and simplifications. The artificial intelligence quantitative method needs a mass of expensive sample data. This method is inapplicability in the alternating current field measurement of ocean engineering field. To solve the small samples and the critical quantization problems, a novel physics-informed neural network is constructed for real-time imaging and evaluation of defects. A high-definition alternating current field measurement probe and instrument are designed to achieve high-precision acquisition of distorted magnetic images. A universal current disturbance physical inversion mechanism is developed to obtain the real morphology of defects without considering defect type under uniform guidelines. The physical defect morphology inversion mechanism is embedded into a deep YOLO neural network as one layer to achieve imaging and evaluation of defects with small samples. The results show that the physics-informed neural network has higher evaluation accuracy for defects in real-time with small samples. The detection accuracy reached 99.6% and the average quantization error was 1.32.
- 13 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-14
Physics-Informed Neural Network for Real-Time Imaging and Evaluation of Defect Based on High-Definition ACFM Probe
Defects reduce the bearing capacity of underwater structures. The determination of defect size provides guidance for underwater structure safety assessment and maintenance. Alternating current field measurement technique is widely used in underwater structure detection for the advantages of non-contact detection and quantitative ability of defects. Generally, the calibration and physical mechanism inversion methods are proposed to evaluate dimensions of defects with a lot of assumptions and simplifications. The artificial intelligence quantitative method needs a mass of expensive sample data. This method is inapplicability in the alternating current field measurement of ocean engineering field. To solve the small samples and the critical quantization problems, a novel physics-informed neural network is constructed for real-time imaging and evaluation of defects. A high-definition alternating current field measurement probe and instrument are designed to achieve high-precision acquisition of distorted magnetic images. A universal current disturbance physical inversion mechanism is developed to obtain the real morphology of defects without considering defect type under uniform guidelines. The physical defect morphology inversion mechanism is embedded into a deep YOLO neural network as one layer to achieve imaging and evaluation of defects with small samples. The results show that the physics-informed neural network has higher evaluation accuracy for defects in real-time with small samples. The detection accuracy reached 99.6% and the average quantization error was 1.32.
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Face-Shear Single-Mode Guided Wave for Prediction of Double-Ended Fatigue Crack Propagation Using Particle Filter Method
Fatigue cracks pose a serious safety risk in offshore platform steel structures. Studying fatigue crack prediction is crucial for ensuring structural safety during service. Currently, a prediction method based on guided wave monitoring and particle filter prediction is widely used for predicting fatigue crack propagation. However, this method is limited by the multi-modal characteristics of guided waves, making it difficult to extract features from the crack reflection signals. Additionally, it is only suitable for single-ended fatigue cracks, which complicates direct application to double-ended fatigue cracks. In this context, this paper proposes a novel particle filter prediction algorithm based on the single-mode shear horizontal (SH) guided wave and double-ended fatigue crack growth state model. First, a Face-Shear-type Lead Zirconate Titanate(PbZrTiO₃, PZT) probe is designed to excite the single-mode SH guided wave, and an observation model is established based on the reflected signals from the cracks. Second, the state model of fatigue crack growth is constructed by obtaining crack length growth data through fatigue tests. Finally, the accuracy of the proposed method is validated through an experimental study. The experimental results show that the average prediction error in the propagation length of the fatigue crack is 1.1%.
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Face-Shear Single-Mode Guided Wave for Prediction of Double-Ended Fatigue Crack Propagation Using Particle Filter Method
Fatigue cracks pose a serious safety risk in offshore platform steel structures. Studying fatigue crack prediction is crucial for ensuring structural safety during service. Currently, a prediction method based on guided wave monitoring and particle filter prediction is widely used for predicting fatigue crack propagation. However, this method is limited by the multi-modal characteristics of guided waves, making it difficult to extract features from the crack reflection signals. Additionally, it is only suitable for single-ended fatigue cracks, which complicates direct application to double-ended fatigue cracks. In this context, this paper proposes a novel particle filter prediction algorithm based on the single-mode shear horizontal (SH) guided wave and double-ended fatigue crack growth state model. First, a Face-Shear-type Lead Zirconate Titanate(PbZrTiO₃, PZT) probe is designed to excite the single-mode SH guided wave, and an observation model is established based on the reflected signals from the cracks. Second, the state model of fatigue crack growth is constructed by obtaining crack length growth data through fatigue tests. Finally, the accuracy of the proposed method is validated through an experimental study. The experimental results show that the average prediction error in the propagation length of the fatigue crack is 1.1%.
- 6 May 2025
- Published by Elsevier in NDT & E International
- Vol. 155
Recent development of alternating current field measurement technology for defects detection: A review
- 6 May 2025
- Published by Elsevier in NDT & E International
- Vol. 155
Recent development of alternating current field measurement technology for defects detection: A review
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 10663-10672
A Novel Shear Horizontal Guided Wave EMAT With Periodic Solenoid Coils and a Single Magnet
Periodic Permanent Magnets Electromagnetic Acoustic Transducers (PPM EMATs) are commonly employed to generate Shear Horizontal (SH) guided waves for defect scanning in steel structures. During scanning, electromagnets can be used as alternatives to permanent magnets to generate static bias magnetic fields, thereby addressing the problem of permanent magnets attracting iron filings on the surface of steel structures. However, since the PPM EMATs have multiple magnet units and complex magnetic field distributions, replacing permanent magnets with electromagnets presents significant challenges. In this paper, a novel SH guided waves EMAT with Periodic Solenoid Coils (PSC) and a single magnet (referred to as the PSC EMAT) was developed. The design methodology for the PSC EMATs was presented, using the excitation of the single SH0 mode guided waves in a steel plate as a case study. The transduction process and excitation performance of the PSC EMATs were analyzed through both Finite Element (FE) simulations and experimental investigations. The results from both simulations and experiments demonstrate that the PSC EMAT can effectively generate single SH0 mode guided waves that propagate in four directions, with the forward directions identified as the primary orientations for defect inspection. These findings indicate that PSC EMATs can reliably generate and receive SH guided waves using a simplified static bias magnetic field, providing a foundation for the future application of electromagnets.
- 10 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (7) , 10663-10672
A Novel Shear Horizontal Guided Wave EMAT With Periodic Solenoid Coils and a Single Magnet
Periodic Permanent Magnets Electromagnetic Acoustic Transducers (PPM EMATs) are commonly employed to generate Shear Horizontal (SH) guided waves for defect scanning in steel structures. During scanning, electromagnets can be used as alternatives to permanent magnets to generate static bias magnetic fields, thereby addressing the problem of permanent magnets attracting iron filings on the surface of steel structures. However, since the PPM EMATs have multiple magnet units and complex magnetic field distributions, replacing permanent magnets with electromagnets presents significant challenges. In this paper, a novel SH guided waves EMAT with Periodic Solenoid Coils (PSC) and a single magnet (referred to as the PSC EMAT) was developed. The design methodology for the PSC EMATs was presented, using the excitation of the single SH0 mode guided waves in a steel plate as a case study. The transduction process and excitation performance of the PSC EMATs were analyzed through both Finite Element (FE) simulations and experimental investigations. The results from both simulations and experiments demonstrate that the PSC EMAT can effectively generate single SH0 mode guided waves that propagate in four directions, with the forward directions identified as the primary orientations for defect inspection. These findings indicate that PSC EMATs can reliably generate and receive SH guided waves using a simplified static bias magnetic field, providing a foundation for the future application of electromagnets.
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 919-928
Conditional Denoising Diffusion Model-Based Defect Reconstruction for Alternating Current Field Measurement
Defect detection is critical for safely operating equipment in harsh environments. Defect reconstruction, as a representative defect detection method, visualizes defects morphology to support equipment maintenance decisions. Existing defect reconstruction methods usually rely on simple mathematical calculations and physical principles, and the reconstructed defects deviate significantly from the real defect patterns. To enhance the accuracy of defect reconstruction, we propose a defect reconstruction algorithm based on the conditional denoising diffusion model (CDDM) for alternating current field measurement (ACFM). The diffusion model exhibits strong generative capabilities, particularly when provided with suitable conditions, enabling it to produce results that meet specific requirements according to the given conditions. Specifically, we first utilize the ACFM technique to obtain the induced magnetic field Bz signal around the crack and reconstruct the defect according to the dual gradient fusion algorithm (DGFA). We then utilize the defects reconstructed image by DGFA as a condition to guide the CDDM to reconstruct the defects morphology. The experimental results show that the CDDM can accurately reconstruct defects length and angle and that the model is capable of reconstructing cracks of smaller lengths (as small as 1 mm). Compared to existing defect reconstruction algorithms, our model achieves the best performance. The average errors in the reconstructed defect crack length and angle based on CDDM are 0.428mm and 0.417°, respectively.
- 11 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 919-928
Conditional Denoising Diffusion Model-Based Defect Reconstruction for Alternating Current Field Measurement
Defect detection is critical for safely operating equipment in harsh environments. Defect reconstruction, as a representative defect detection method, visualizes defects morphology to support equipment maintenance decisions. Existing defect reconstruction methods usually rely on simple mathematical calculations and physical principles, and the reconstructed defects deviate significantly from the real defect patterns. To enhance the accuracy of defect reconstruction, we propose a defect reconstruction algorithm based on the conditional denoising diffusion model (CDDM) for alternating current field measurement (ACFM). The diffusion model exhibits strong generative capabilities, particularly when provided with suitable conditions, enabling it to produce results that meet specific requirements according to the given conditions. Specifically, we first utilize the ACFM technique to obtain the induced magnetic field Bz signal around the crack and reconstruct the defect according to the dual gradient fusion algorithm (DGFA). We then utilize the defects reconstructed image by DGFA as a condition to guide the CDDM to reconstruct the defects morphology. The experimental results show that the CDDM can accurately reconstruct defects length and angle and that the model is capable of reconstructing cracks of smaller lengths (as small as 1 mm). Compared to existing defect reconstruction algorithms, our model achieves the best performance. The average errors in the reconstructed defect crack length and angle based on CDDM are 0.428mm and 0.417°, respectively.
- 29 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
A Flexible Alternating Current Field Measurement Magnetic Sensor Array for In Situ Inspection of Cracks in Underwater Structure
Alternating current field measurement (ACFM) technique has been widely used in defect inspection of underwater metal structures. However, due to the high cost of inspection, it is difficult to carry out nondestructive testing (NDT) regularly to obtain the health status of key nodes of structures. And the quantification of defects depends on simple empirical formula, which leads to large quantization error. In this paper, a flexible ACFM magnetic sensor array for in-situ inspection of underwater structural cracks is proposed. A in-situ inspection probe based on the sensor array is manufactured and can be fixed on the surface of underwater curved structures. The probe can realize visual imaging of cracks in underwater carbon steel structure to obtain the damage status of key nodes of the structure regularly. According to the inspection image, a crack quantification method based on multi-physical features fusion convolution neural network, which is used for quantification of crack length, depth and angle. The experimental results show that the in-situ inspection probe can realize the visual imaging of cracks. The quantification method can accurately evaluate the crack dimensions. The average length error, average depth error and average angle error are 0.41 mm, 0.169 mm and 1.131° respectively.
- 29 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-10
A Flexible Alternating Current Field Measurement Magnetic Sensor Array for In Situ Inspection of Cracks in Underwater Structure
Alternating current field measurement (ACFM) technique has been widely used in defect inspection of underwater metal structures. However, due to the high cost of inspection, it is difficult to carry out nondestructive testing (NDT) regularly to obtain the health status of key nodes of structures. And the quantification of defects depends on simple empirical formula, which leads to large quantization error. In this paper, a flexible ACFM magnetic sensor array for in-situ inspection of underwater structural cracks is proposed. A in-situ inspection probe based on the sensor array is manufactured and can be fixed on the surface of underwater curved structures. The probe can realize visual imaging of cracks in underwater carbon steel structure to obtain the damage status of key nodes of the structure regularly. According to the inspection image, a crack quantification method based on multi-physical features fusion convolution neural network, which is used for quantification of crack length, depth and angle. The experimental results show that the in-situ inspection probe can realize the visual imaging of cracks. The quantification method can accurately evaluate the crack dimensions. The average length error, average depth error and average angle error are 0.41 mm, 0.169 mm and 1.131° respectively.
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (1) , 679-688
Uniform Alternating Current Field Monitoring Sensor Array for Imaging and Quantitation of Cracks in Aluminum Alloy Structures
Aircraft structures are prone to fatigue cracks under various loads, which seriously threaten the safety performance of aircraft. Therefore, it is particularly important to carry out long-term structural health monitoring (SHM) for key nodes of aircraft structures. This paper attempts to apply alternating current field measurement (ACFM) technique to the SHM field. In this paper, based on the principle of ACFM, a uniform alternating current field monitoring (UACFM) technique is proposed. Through the simulation analysis, the change law of the corresponding monitoring characteristic signal is explored when the length, depth and angle of the crack change respectively. Based on monitoring images, a crack dimension quantitation method is proposed. In addition, by studying the optimal arrangement method of magnetic field sensor arrays, a UACFM sensor array for imaging and quantifying of cracks in aluminum alloy structures is produced, which can monitor the existence of the cracks. Several groups of different cracks on the specimen were tested. The results show that UACFM technology and the quantitation method proposed in this paper can realize the imaging monitoring of the cracks, and preliminarily quantify the crack dimension (length, depth, angle), which verifies the reliability and effectiveness of this technology and provides a new method for SHM.
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (1) , 679-688
Uniform Alternating Current Field Monitoring Sensor Array for Imaging and Quantitation of Cracks in Aluminum Alloy Structures
Aircraft structures are prone to fatigue cracks under various loads, which seriously threaten the safety performance of aircraft. Therefore, it is particularly important to carry out long-term structural health monitoring (SHM) for key nodes of aircraft structures. This paper attempts to apply alternating current field measurement (ACFM) technique to the SHM field. In this paper, based on the principle of ACFM, a uniform alternating current field monitoring (UACFM) technique is proposed. Through the simulation analysis, the change law of the corresponding monitoring characteristic signal is explored when the length, depth and angle of the crack change respectively. Based on monitoring images, a crack dimension quantitation method is proposed. In addition, by studying the optimal arrangement method of magnetic field sensor arrays, a UACFM sensor array for imaging and quantifying of cracks in aluminum alloy structures is produced, which can monitor the existence of the cracks. Several groups of different cracks on the specimen were tested. The results show that UACFM technology and the quantitation method proposed in this paper can realize the imaging monitoring of the cracks, and preliminarily quantify the crack dimension (length, depth, angle), which verifies the reliability and effectiveness of this technology and provides a new method for SHM.