Shuaijian Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shuaijian Yang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Xingyu Jiang
Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong P. R. China
4 shared publications Chenqi Liu
Shenzhen Key Laboratory of Smart Healthcare Engineering Guangdong Provincial Key Laboratory of Advanced Biomaterials Department of Biomedical Engineering Southern University of Science and Technology No. 1088 Xueyuan Rd, Nanshan District Shenzhen Guangdong 518055 P. R. China
3 shared publicationsJin Shang
Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088 Xueyuan Rd, Nanshan District, Shenzhen, Guangdong 518055, China
2 shared publications- Junrui Zhang
College of Pharmacy and Bioengineering, Chongqing University of Technology, Chongqing, 400054, P. R. China
2 shared publications Chen Hang
Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, P. R. China
1 shared publicationJie Qi
Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, P. R. China
1 shared publication
Latest Publications
- 30 October 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (6) , e03353
Stretchable Patch for Multimodal Theranostic Human Machine Interface
Advanced human‐machine interfaces are limited by the integration level and coverage fraction of existing wearable materials and devices. One typical example is the management of muscle fatigue. Although real‐time monitoring and early intervention are crucial for this application, current devices cannot treat muscle fatigue promptly because they lack the integration of such theranostic functions. To address this issue, this study presents a decimeter‐scale, stretchable, and flexible multimodal theranostic patch (FMTP) that integrates monitoring and therapy on a large‐area film (≈400 cm 2 ). The FMTP incorporates metal‐polymer conductor (MPC) strain sensors and bidirectional electrodes (BDE), constructing a bimodal monitoring system. The MPC sensors can monitor the human neck movement, while the BDE array provides both surface electromyography (sEMG) acquisition and therapeutic electrical stimulation. Once the muscle fatigue is detected in a poor posture, the FMTP conducts electrical stimulation and heat treatment to give a closed‐loop theranostic intervention. The large‐area structure design ensures high signal fidelity by increasing integration level, and supports multi‐site theranostic functions over a broader range. Meanwhile, the entire device is stretchable to achieve better performance by improving skin conformability. In the future, the wearable solution introduced here holds significant potential for medical devices in health monitoring and human‐machine interface.
- 30 October 2025
- Published by Wiley in Advanced Healthcare Materials
- Vol. 15 (6) , e03353
Stretchable Patch for Multimodal Theranostic Human Machine Interface
Advanced human‐machine interfaces are limited by the integration level and coverage fraction of existing wearable materials and devices. One typical example is the management of muscle fatigue. Although real‐time monitoring and early intervention are crucial for this application, current devices cannot treat muscle fatigue promptly because they lack the integration of such theranostic functions. To address this issue, this study presents a decimeter‐scale, stretchable, and flexible multimodal theranostic patch (FMTP) that integrates monitoring and therapy on a large‐area film (≈400 cm 2 ). The FMTP incorporates metal‐polymer conductor (MPC) strain sensors and bidirectional electrodes (BDE), constructing a bimodal monitoring system. The MPC sensors can monitor the human neck movement, while the BDE array provides both surface electromyography (sEMG) acquisition and therapeutic electrical stimulation. Once the muscle fatigue is detected in a poor posture, the FMTP conducts electrical stimulation and heat treatment to give a closed‐loop theranostic intervention. The large‐area structure design ensures high signal fidelity by increasing integration level, and supports multi‐site theranostic functions over a broader range. Meanwhile, the entire device is stretchable to achieve better performance by improving skin conformability. In the future, the wearable solution introduced here holds significant potential for medical devices in health monitoring and human‐machine interface.
- 27 September 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (40) , 27107-27125
Nanoscale Strategies for Enhancing the Performance of Adhesive Dry Electrodes for the Skin
High-quality electrophysiological monitoring requires electrodes to maintain a compliant and stable skin contact. This necessitates low impedance, good skin compliance, and strong adhesion to ensure continuous and stable contact under dynamic conditions. In this context, adhesive epidermal dry electrodes are advancing rapidly, which is promising for long-term applications in clinical diagnosis, wearable health monitoring, and human-machine interfaces. However, challenges persist, as conventional technologies usually fall short of meeting the high standards required for electrophysiological electrodes. This Perspective discusses four key aspects for high-performance epidermal electrodes from an adhesive perspective: initial adhesion, water resistance, dynamic stability, and removal simplicity. We review recent nanoscale strategies addressing these issues, providing a comprehensive guideline to enhance the application performance of epidermal dry electrodes. Additionally, we explore key nanoscale strategies and their associated functions, future technology roadmaps, and prospects for dry adhesive epidermal electrodes.
- 27 September 2024
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 18 (40) , 27107-27125
Nanoscale Strategies for Enhancing the Performance of Adhesive Dry Electrodes for the Skin
High-quality electrophysiological monitoring requires electrodes to maintain a compliant and stable skin contact. This necessitates low impedance, good skin compliance, and strong adhesion to ensure continuous and stable contact under dynamic conditions. In this context, adhesive epidermal dry electrodes are advancing rapidly, which is promising for long-term applications in clinical diagnosis, wearable health monitoring, and human-machine interfaces. However, challenges persist, as conventional technologies usually fall short of meeting the high standards required for electrophysiological electrodes. This Perspective discusses four key aspects for high-performance epidermal electrodes from an adhesive perspective: initial adhesion, water resistance, dynamic stability, and removal simplicity. We review recent nanoscale strategies addressing these issues, providing a comprehensive guideline to enhance the application performance of epidermal dry electrodes. Additionally, we explore key nanoscale strategies and their associated functions, future technology roadmaps, and prospects for dry adhesive epidermal electrodes.
- 12 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (33) , 43880-43891
Highly Adhesive and Stretchable Epidermal Electrode for Bimodal Recording Patch
For numerous biological and human-machine applications, it is critical to have a stable electrophysiological interface to obtain reliable signals. To achieve this, epidermal electrodes should possess conductivity, stretchability, and adhesiveness. However, limited types of materials can simultaneously satisfy these requirements to provide satisfying recording performance. Here, we present a dry electromyography (EMG) electrode based on conductive polymers and tea polyphenol (CPT), which offers adhesiveness (0.51 N/cm), stretchability (157%), and low impedance (14 kΩ cm2 at 100 Hz). The adhesiveness of the electrode is attributed to the interaction between catechol groups and hydroxyls in the polymer blend. This adhesive electrode ensures stable EMG recording even in the presence of vibrations and provides signals with a high signal-to-noise ratio (>25 dB) for over 72 h. By integrating the CPT electrode with a liquid metal strain sensor, we have developed a bimodal rehabilitation monitoring patch (BRMP) for sports injuries. The patch utilizes Kinesio Tape as a substrate, which serves to accelerate rehabilitation. It also tackles the challenge of recording with knee braces by fitting snugly between the brace and the skin, due to its thin and stretchable design. CPT electrodes not only enable BRMP to assist clinicians in formulating effective rehabilitation plans and offer patients a more comfortable rehabilitation experience, but also hold promise for future applications in biological and human-machine interface domains.
- 12 August 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (33) , 43880-43891
Highly Adhesive and Stretchable Epidermal Electrode for Bimodal Recording Patch
For numerous biological and human-machine applications, it is critical to have a stable electrophysiological interface to obtain reliable signals. To achieve this, epidermal electrodes should possess conductivity, stretchability, and adhesiveness. However, limited types of materials can simultaneously satisfy these requirements to provide satisfying recording performance. Here, we present a dry electromyography (EMG) electrode based on conductive polymers and tea polyphenol (CPT), which offers adhesiveness (0.51 N/cm), stretchability (157%), and low impedance (14 kΩ cm2 at 100 Hz). The adhesiveness of the electrode is attributed to the interaction between catechol groups and hydroxyls in the polymer blend. This adhesive electrode ensures stable EMG recording even in the presence of vibrations and provides signals with a high signal-to-noise ratio (>25 dB) for over 72 h. By integrating the CPT electrode with a liquid metal strain sensor, we have developed a bimodal rehabilitation monitoring patch (BRMP) for sports injuries. The patch utilizes Kinesio Tape as a substrate, which serves to accelerate rehabilitation. It also tackles the challenge of recording with knee braces by fitting snugly between the brace and the skin, due to its thin and stretchable design. CPT electrodes not only enable BRMP to assist clinicians in formulating effective rehabilitation plans and offer patients a more comfortable rehabilitation experience, but also hold promise for future applications in biological and human-machine interface domains.
- Top Cited PapersOpen Access
- 14 October 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-16
Stretchable surface electromyography electrode array patch for tendon location and muscle injury prevention
Surface electromyography (sEMG) can provide multiplexed information about muscle performance. If current sEMG electrodes are stretchable, arrayed, and able to be used multiple times, they would offer adequate high-quality data for continuous monitoring. The lack of these properties delays the widespread use of sEMG in clinics and in everyday life. Here, we address these constraints by design of an adhesive dry electrode using tannic acid, polyvinyl alcohol, and PEDOT:PSS (TPP). The TPP electrode offers superior stretchability (~200%) and adhesiveness (0.58 N/cm) compared to current electrodes, ensuring stable and long-term contact with the skin for recording (>20 dB; >5 days). In addition, we developed a metal-polymer electrode array patch (MEAP) comprising liquid metal (LM) circuits and TPP electrodes. The MEAP demonstrated better conformability than commercial arrays, resulting in higher signal-to-noise ratio and more stable recordings during muscle movements. Manufactured using scalable screen-printing, these MEAPs feature a completely stretchable material and array architecture, enabling real-time monitoring of muscle stress, fatigue, and tendon displacement. Their potential to reduce muscle and tendon injuries and enhance performance in daily exercise and professional sports holds great promise.
- 14 October 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-16
Top Cited PapersOpen AccessStretchable surface electromyography electrode array patch for tendon location and muscle injury prevention
Surface electromyography (sEMG) can provide multiplexed information about muscle performance. If current sEMG electrodes are stretchable, arrayed, and able to be used multiple times, they would offer adequate high-quality data for continuous monitoring. The lack of these properties delays the widespread use of sEMG in clinics and in everyday life. Here, we address these constraints by design of an adhesive dry electrode using tannic acid, polyvinyl alcohol, and PEDOT:PSS (TPP). The TPP electrode offers superior stretchability (~200%) and adhesiveness (0.58 N/cm) compared to current electrodes, ensuring stable and long-term contact with the skin for recording (>20 dB; >5 days). In addition, we developed a metal-polymer electrode array patch (MEAP) comprising liquid metal (LM) circuits and TPP electrodes. The MEAP demonstrated better conformability than commercial arrays, resulting in higher signal-to-noise ratio and more stable recordings during muscle movements. Manufactured using scalable screen-printing, these MEAPs feature a completely stretchable material and array architecture, enabling real-time monitoring of muscle stress, fatigue, and tendon displacement. Their potential to reduce muscle and tendon injuries and enhance performance in daily exercise and professional sports holds great promise.