Qingyan Rao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Qingyan Rao has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Chen Hang
Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088, Xueyuan Road, Nanshan District, Shenzhen, Guangdong 518055, P. R. China
4 shared publicationsJie Qi
Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088, Xueyuan Road, Nanshan District, Shenzhen, Guangdong 518055, P. R. China
4 shared publications- Xingyu Jiang
Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering Southern University of Science and Technology Shenzhen Guangdong P. R. China
4 shared publications Li Ding
Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088, Xueyuan Road, Nanshan District, Shenzhen, Guangdong 518055, P. R. China
3 shared publicationsJialu Wu
Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088, Xueyuan Road, Nanshan District, Shenzhen, Guangdong 518055, P. R. China
2 shared publicationsChenqi Liu
Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, P. R. China
1 shared publication
Latest Publications
- 23 October 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (44) , 15945-15954
Long-Term Cardiac Electrical Imaging Enabled by Ultrahigh-Resolution Foldable Heart–Machine Interfaces
The advancement of electrophysiological mapping for cardiac arrhythmias relies critically on overcoming key interface challenges: long-term biocompatibility, spatial resolution limitations, and mechanical mismatch with dynamic cardiac tissue. To address these, we developed a rapid encapsulation method for liquid metal electrode arrays at the 10-μm scale, enabling the fabrication of ultrahigh-density and flexible sensor arrays (∼28570 sensors/cm2) within 30 min. It constructs a fully foldable, high-density heart-machine interface deployable via minimally invasive access (2 reentrant pattern in ventricular fibrillation) while maintaining long-term reliability (100% electrode functionality over 98 days). This technology holds promise for advancing diverse human-machine interfaces for other organs and tissues, enabling the integration of multiple organs and even the whole body for comprehensive health management.
- 23 October 2025
- Published by American Chemical Society (ACS) in Nano Letters
- Vol. 25 (44) , 15945-15954
Long-Term Cardiac Electrical Imaging Enabled by Ultrahigh-Resolution Foldable Heart–Machine Interfaces
The advancement of electrophysiological mapping for cardiac arrhythmias relies critically on overcoming key interface challenges: long-term biocompatibility, spatial resolution limitations, and mechanical mismatch with dynamic cardiac tissue. To address these, we developed a rapid encapsulation method for liquid metal electrode arrays at the 10-μm scale, enabling the fabrication of ultrahigh-density and flexible sensor arrays (∼28570 sensors/cm2) within 30 min. It constructs a fully foldable, high-density heart-machine interface deployable via minimally invasive access (2 reentrant pattern in ventricular fibrillation) while maintaining long-term reliability (100% electrode functionality over 98 days). This technology holds promise for advancing diverse human-machine interfaces for other organs and tissues, enabling the integration of multiple organs and even the whole body for comprehensive health management.
- 30 March 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (13) , 13118-13127
A Bilayer Microfluidics-Based Elastic Encapsulation Method of Liquid Metal Circuits with Cellular Resolution
Mechanical mismatches at the microscale between bioelectronics and cells severely hinder the successful acquisition of high-quality and stable electrophysiological signals. Room-temperature liquid metals (EGaIn), which possess a near-zero Young's modulus, present a promising material for achieving stable conformal contact with biological tissues. However, the fluidity of liquid metals limits the elastic encapsulation of the patterned circuits with cellular resolution. To address this challenge, we develop a bilayer microfluidics-based method to elastically encapsulate a high-resolution electrode array (20 μm) within several minutes (300% strain), and excellent biocompatibility, facilitating long-term stable interfacing with cardiomyocytes and enabling the collection of high-quality (∼30 dB) cell field potential signals as well as epicardial signals (∼42 dB) from living rat models. This rapid and straightforward encapsulation approach improves the precision and integration of liquid metal-based flexible electronics, holding the promise of high-resolution monitoring and treatment, such as electrophysiological mapping, electrical stimulation, and other therapeutic interventions at the cellular levels.
- 30 March 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (13) , 13118-13127
A Bilayer Microfluidics-Based Elastic Encapsulation Method of Liquid Metal Circuits with Cellular Resolution
Mechanical mismatches at the microscale between bioelectronics and cells severely hinder the successful acquisition of high-quality and stable electrophysiological signals. Room-temperature liquid metals (EGaIn), which possess a near-zero Young's modulus, present a promising material for achieving stable conformal contact with biological tissues. However, the fluidity of liquid metals limits the elastic encapsulation of the patterned circuits with cellular resolution. To address this challenge, we develop a bilayer microfluidics-based method to elastically encapsulate a high-resolution electrode array (20 μm) within several minutes (300% strain), and excellent biocompatibility, facilitating long-term stable interfacing with cardiomyocytes and enabling the collection of high-quality (∼30 dB) cell field potential signals as well as epicardial signals (∼42 dB) from living rat models. This rapid and straightforward encapsulation approach improves the precision and integration of liquid metal-based flexible electronics, holding the promise of high-resolution monitoring and treatment, such as electrophysiological mapping, electrical stimulation, and other therapeutic interventions at the cellular levels.
- Open Access
- 13 November 2024
- Published by Springer Nature in Research Square
A completely foldable patch elastically encapsulated by bilayer microfluidics enables high-resolution electrical imaging at human-machine interfaces
The human-machine interface faces several challenges, including long-term stability, high resolution, and full flexibility. Especially for the heart-machine interface, these challenges are even harder to overcome because the heart is a moist, soft, and continuously and intensely moving organ with severe deformation. Current interfaces lack the capacity for both high-density electrodes and full flexibility. Additionally, the encapsulation processes they offer are neither swift nor efficient. To address these challenges, we developed a bilayer microfluidics-based method to elastically encapsulate high-resolution interfaces within the unique and demanding context of the heart. The encapsulation process requires only several minutes. The alignment-free method overcomes the limitations of packaging polymers and high-resolution aligners, enabling cost-effective, scalable manufacturing for interfaces and establishing three-dimensional (3D) circuits. We fabricated the completely flexible interface, which can fold (diameter < 3 mm) and be delivered into the chest through minimally invasive access. The heart-machine interface with high-resolution (~ 740 sensors/cm2) is long-term reliable (100% survival rate of functional channels) over 98-day implantation (> 3 months). It can accurately identify electrical heterogeneity for 3D high-resolution imaging in various scenarios, including living rat, rabbit, and dog models. This technology holds promise for advancing diverse human-machine interfaces for other organs and tissues, enabling the integration of multiple organs and even the whole body for comprehensive health management.
- 13 November 2024
- Published by Springer Nature in Research Square
Open AccessA completely foldable patch elastically encapsulated by bilayer microfluidics enables high-resolution electrical imaging at human-machine interfaces
The human-machine interface faces several challenges, including long-term stability, high resolution, and full flexibility. Especially for the heart-machine interface, these challenges are even harder to overcome because the heart is a moist, soft, and continuously and intensely moving organ with severe deformation. Current interfaces lack the capacity for both high-density electrodes and full flexibility. Additionally, the encapsulation processes they offer are neither swift nor efficient. To address these challenges, we developed a bilayer microfluidics-based method to elastically encapsulate high-resolution interfaces within the unique and demanding context of the heart. The encapsulation process requires only several minutes. The alignment-free method overcomes the limitations of packaging polymers and high-resolution aligners, enabling cost-effective, scalable manufacturing for interfaces and establishing three-dimensional (3D) circuits. We fabricated the completely flexible interface, which can fold (diameter < 3 mm) and be delivered into the chest through minimally invasive access. The heart-machine interface with high-resolution (~ 740 sensors/cm2) is long-term reliable (100% survival rate of functional channels) over 98-day implantation (> 3 months). It can accurately identify electrical heterogeneity for 3D high-resolution imaging in various scenarios, including living rat, rabbit, and dog models. This technology holds promise for advancing diverse human-machine interfaces for other organs and tissues, enabling the integration of multiple organs and even the whole body for comprehensive health management.
- Top Cited PapersOpen Access
- 14 October 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-16
Stretchable surface electromyography electrode array patch for tendon location and muscle injury prevention
Surface electromyography (sEMG) can provide multiplexed information about muscle performance. If current sEMG electrodes are stretchable, arrayed, and able to be used multiple times, they would offer adequate high-quality data for continuous monitoring. The lack of these properties delays the widespread use of sEMG in clinics and in everyday life. Here, we address these constraints by design of an adhesive dry electrode using tannic acid, polyvinyl alcohol, and PEDOT:PSS (TPP). The TPP electrode offers superior stretchability (~200%) and adhesiveness (0.58 N/cm) compared to current electrodes, ensuring stable and long-term contact with the skin for recording (>20 dB; >5 days). In addition, we developed a metal-polymer electrode array patch (MEAP) comprising liquid metal (LM) circuits and TPP electrodes. The MEAP demonstrated better conformability than commercial arrays, resulting in higher signal-to-noise ratio and more stable recordings during muscle movements. Manufactured using scalable screen-printing, these MEAPs feature a completely stretchable material and array architecture, enabling real-time monitoring of muscle stress, fatigue, and tendon displacement. Their potential to reduce muscle and tendon injuries and enhance performance in daily exercise and professional sports holds great promise.
- 14 October 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-16
Top Cited PapersOpen AccessStretchable surface electromyography electrode array patch for tendon location and muscle injury prevention
Surface electromyography (sEMG) can provide multiplexed information about muscle performance. If current sEMG electrodes are stretchable, arrayed, and able to be used multiple times, they would offer adequate high-quality data for continuous monitoring. The lack of these properties delays the widespread use of sEMG in clinics and in everyday life. Here, we address these constraints by design of an adhesive dry electrode using tannic acid, polyvinyl alcohol, and PEDOT:PSS (TPP). The TPP electrode offers superior stretchability (~200%) and adhesiveness (0.58 N/cm) compared to current electrodes, ensuring stable and long-term contact with the skin for recording (>20 dB; >5 days). In addition, we developed a metal-polymer electrode array patch (MEAP) comprising liquid metal (LM) circuits and TPP electrodes. The MEAP demonstrated better conformability than commercial arrays, resulting in higher signal-to-noise ratio and more stable recordings during muscle movements. Manufactured using scalable screen-printing, these MEAPs feature a completely stretchable material and array architecture, enabling real-time monitoring of muscle stress, fatigue, and tendon displacement. Their potential to reduce muscle and tendon injuries and enhance performance in daily exercise and professional sports holds great promise.