RFRuijie Fang

Ruijie Fang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ruijie Fang has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Know Me by My Pulse: Toward Practical Continuous Authentication on Wearable Devices via Wrist-Worn PPG

    by Wei Shao, Zequan Liang, Ruoyu Zhang, Ruijie Fang, Ning Miao, Ehsan Kourkchi, Setareh Rafatirad, Houman Homayoun, Chongzhou Fang

    Biometric authentication using physiological signals offers a promising path toward secure and user-friendly access control in wearable devices. While electrocardiogram (ECG) signals have shown high discriminability, their intrusive sensing requirements and discontinuous acquisition limit practicality. Photoplethysmography (PPG), on the other hand, enables continuous, non-intrusive authentication with seamless integration into wrist-worn wearable devices. However, most prior work relies on high-frequency PPG (e.g., 75 - 500 Hz) and complex deep models, which incur significant energy and computational overhead, impeding deployment in power-constrained real-world systems. In this paper, we present the first real-world implementation and evaluation of a continuous authentication system on a smartwatch, We-Be Band, using low-frequency (25 Hz) multi-channel PPG signals. Our method employs a Bi-LSTM with attention mechanism to extract identity-specific features from short (4 s) windows of 4-channel PPG. Through extensive evaluations on both public datasets (PTTPPG) and our We-Be Dataset (26 subjects), we demonstrate strong classification performance with an average test accuracy of 88.11%, macro F1-score of 0.88, False Acceptance Rate (FAR) of 0.48%, False Rejection Rate (FRR) of 11.77%, and Equal Error Rate (EER) of 2.76%. Our 25 Hz system reduces sensor power consumption by 53% compared to 512 Hz and 19% compared to 128 Hz setups without compromising performance. We find that sampling at 25 Hz preserves authentication accuracy, whereas performance drops sharply at 20 Hz while offering only trivial additional power savings, underscoring 25 Hz as the practical lower bound. Additionally, we find that models trained exclusively on resting data fail under motion, while activity-diverse training improves robustness across physiological states.

  • Top Cited Papers
    Open Access

    Survey on Pain Detection Using Machine Learning Models: Narrative Review

    by Ruijie Fang, Elahe Hosseini, Ruoyu Zhang, Chongzhou Fang, Setareh Rafatirad, Houman Homayoun

    Background: Pain, a leading reason people seek medical care, has become a social issue. Automated pain assessment has seen notable advancements over recent decades, addressing a critical need in both clinical and everyday settings. Objective: The objective of this survey was to provide a comprehensive overview of pain and its mechanisms, to explore existing research on automated pain recognition modalities, and to identify key challenges and future directions in this field. Methods: A literature review was conducted, analyzing studies focused on various modalities for automated pain recognition. The modalities reviewed include facial expressions, physiological signals, audio cues, and pupil dilation, with a focus on their efficacy and application in pain assessment. Results: The survey found that each modality offers unique contributions to automated pain recognition, with facial expressions and physiological signals showing particular promise. However, the reliability and accuracy of these modalities vary, often depending on factors such as individual variability and environmental conditions. Conclusions: While automated pain recognition has progressed considerably, challenges remain in achieving consistent accuracy across diverse populations and contexts. Future research directions are suggested to address these challenges, enhancing the reliability and applicability of automated pain assessment in clinical practice.


  • Open Access

    APEX: Attention on Personality based Emotion ReXgnition Framework

    by Ruijie Fang, Ruoyu Zhang, Elahe Hosseini, Chongzhou Fang, Mahdi Eslaminehr, Setareh Rafatirad, Houman Homayoun

    Automated emotion recognition has applications in various fields, such as human-machine interaction, healthcare, security, education, and emotion-aware recommendation/feedback systems. Developing methods to analyze human emotions accurately is essential to enable such diverse applications. Multiple studies have been conducted to explore the possibility of using physiological signals and machine-learning techniques to evaluate human emotions. Furthermore, internal factors such as personality have been considered and involved in emotion recognition. However, integrating personality that is user specific within traditional machine-learning methods that use user-agnostic large data sets has become a critical problem. This study proposes the APEX: attention on personality-based emotion recognition framework, in which multiple weak classifiers are trained on physiological signals of each participant's data, and the classification results are reweighed based on the personality correlations between corresponding subjects and test subjects. Experiments have been conducted on the ASCERTAIN dataset, and the results show that the proposed framework outperforms existing studies.

  • Open Access

    Advanced Energy-Efficient System for Precision Electrodermal Activity Monitoring in Stress Detection

    by Ruoyu Zhang, Ruijie Fang, Elahe Hosseini, Chongzhou Fang, Ning Miao, Houman Homayoun

    This paper presents a novel Electrodermal Activity (EDA) signal acquisition system, designed to address the challenges of stress monitoring in contemporary society, where stress affects one in four individuals. Our system focuses on enhancing the accuracy and efficiency of EDA measurements, a reliable indicator of stress. Traditional EDA monitoring solutions often grapple with trade-offs between sensor placement, cost, and power consumption, leading to compromised data accuracy. Our innovative design incorporates an adaptive gain mechanism, catering to the broad dynamic range and high-resolution needs of EDA data analysis. The performance of our system was extensively tested through simulations and a custom Printed Circuit Board (PCB), achieving an error rate below 1\% and maintaining power consumption at a mere 700$μ$A under a 3.7V power supply. This research contributes significantly to the field of wearable health technology, offering a robust and efficient solution for long-term stress monitoring.

  • Open Access

    Privee: A Wearable for Real-Time Bladder Monitoring System

    by Ruoyu Zhang, Ruijie Fang, Chongzhou Fang, Houman Homayoun, Gozde Goncu Berk

    Urinary incontinence (UI) is a prevalent condition affecting millions of individuals worldwide, leading to various physical, social, and psychological challenges that diminish their quality of life. Current management approaches primarily focus on containment rather than proactive monitoring and warning systems. This paper presents the development and evaluation of a novel wearable technology called Privee, designed as an unobtrusive undergarment to monitor bladder fullness in real-time. Privee utilizes e-textile-based bioimpedance spectroscopy technology, which noninvasively assesses bladder fullness by analyzing the electrical properties of body tissues and fluids. The undergarment incorporates eight embroidered electrodes and textile transmission lines seamlessly integrated into the fabric. By continuously monitoring the bioimpedance signals from the bladder, Privee provides real-time information about the bladder’s fullness level. This data is processed using a specialized algorithm to estimate the need for urination. The noninvasive nature of Privee eliminates the discomfort and risks associated with invasive monitoring methods, offering a user-friendly and convenient solution for individuals with UI, overactive bladder, or post-operative care needs. This innovative technology has the potential to improve patients’ quality of life and optimize healthcare costs associated with UI management.


  • Open Access

    Survey on Pain Detection Using Machine Learning Models: Narrative Review (Preprint)

    by Ruijie Fang, Elahe Hosseini, Ruoyu Zhang, Chongzhou Fang, Setareh Rafatirad, Houman Homayoun

    BACKGROUND Pain, a leading reason people seek medical care, has become a social issue. Automated pain assessment has seen notable advancements over recent decades, addressing a critical need in both clinical and everyday settings. OBJECTIVE The objective of this survey was to provide a comprehensive overview of pain and its mechanisms, to explore existing research on automated pain recognition modalities, and to identify key challenges and future directions in this field. METHODS A literature review was conducted, analyzing studies focused on various modalities for automated pain recognition. The modalities reviewed include facial expressions, physiological signals, audio cues, and pupil dilation, with a focus on their efficacy and application in pain assessment. RESULTS The survey found that each modality offers unique contributions to automated pain recognition, with facial expressions and physiological signals showing particular promise. However, the reliability and accuracy of these modalities vary, often depending on factors such as individual variability and environmental conditions. CONCLUSIONS While automated pain recognition has progressed considerably, challenges remain in achieving consistent accuracy across diverse populations and contexts. Future research directions are suggested to address these challenges, enhancing the reliability and applicability of automated pain assessment in clinical practice.

  • Open Access

    Short: Real-Time Bladder Monitoring by Bio-impedance Analysis to Aid Urinary Incontinence

    by Ruoyu Zhang, Ruijie Fang, Zhichao Zhang, Elahe Hosseini, Mahdi Orooji, Houman Homayoun, Gozde Goncu-Berk

    The inability to sense the need to urinate is a persistent trouble for many individuals who have urinary incontinence. There are no products for people with urinary incontinence and their caregivers that target the elimination of involuntary urination instead of containing leaks or warning about leaks. Thus, fulfilling the real-time monitoring of the bladder to notify urination time holds a life-changing innovation potential for people with urinary incontinence. In this paper, we propose a low-cost wearable device in the form factor of an unobtrusive belt that uses bio-impedance measurement across the bladder region to notify the patients or caregivers about the need to urinate. We also present results from human subject tests using the proposed wearable prototype with a custom machine-learning algorithm to evaluate the accuracy of the system. Results from the human-subject tests showed an accuracy of over 90% on the binary task of full versus empty bladder states based on the change in bio-impedance values.