Jun Ryu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jun Ryu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Gerard Jounghyun Kim
Digital Experience Laboratory, Korea University, Seoul, NA, Republic of Korea
4 shared publications - Hanseob Kim
Department of Computer Science and Software Engineering, Korea University, Sejong, Republic of Korea
1 shared publication - Min Suk Kim
3-D Systems Packaging Research Center, Georgia Institute of Technology, Atlanta, GA, USA
1 shared publication - Minchae Kim
Digital Experience Laboratory, Korea University, Seoul, Republic of Korea
1 shared publication - Seunghoon Park
Digital Experience Laboratory, Korea University, Korea, Republic of
1 shared publication - Shin-Woong Park
Korea University
1 shared publication
Latest Publications
- Open Access
- 16 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-10
3D based Reverse Optical Flow Estimation: Mitigating Cybersickness via User-motion based Particle Visualization
- 16 November 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-10
Open Access3D based Reverse Optical Flow Estimation: Mitigating Cybersickness via User-motion based Particle Visualization
- Open Access
- 13 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-15
JourneyVR: Designing for Continuous Workflow Experience in Virtual Reality
- 13 April 2026
- Published by Association for Computing Machinery (ACM)
- p. 1-15
Open AccessJourneyVR: Designing for Continuous Workflow Experience in Virtual Reality
- 31 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 32 (5) , 3346-3356
Predicting Cybersickness Trend and Extent Based on FMS Labeled Dataset
Cybersickness has been a hindrance to the widespread adoption of virtual reality. As cybersickness is dynamic, with its manifestation changing constantly, predicting and mitigating it in real time is key. However, previous research has utilized predictive models trained mostly with datasets whose sickness levels were measured and labeled only after experiencing the content. In addition, many datasets rely on physiological signals as input, which makes them difficult to apply in actual VR usage. This makes such timely predictions unreliable or practically infeasible. We have created a publicly available dataset where the ground truth sickness levels were densely marked every 0.5 seconds and adjusted/updated on-demand using the FMS, and purposely excluded the difficult-to-collect physiological data. We demonstrate that predictive models trained with such a dataset, comprising just the content motion profile and FMSdata, can still produce comparably reliable sickness prediction, and more so, when user-specific parameters (e.g., age, gender) are added. The created dataset is available at https://github.com/pvtryan1024/2025_Cybersickness_dataset.
- 31 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Visualization and Computer Graphics
- Vol. 32 (5) , 3346-3356
Predicting Cybersickness Trend and Extent Based on FMS Labeled Dataset
Cybersickness has been a hindrance to the widespread adoption of virtual reality. As cybersickness is dynamic, with its manifestation changing constantly, predicting and mitigating it in real time is key. However, previous research has utilized predictive models trained mostly with datasets whose sickness levels were measured and labeled only after experiencing the content. In addition, many datasets rely on physiological signals as input, which makes them difficult to apply in actual VR usage. This makes such timely predictions unreliable or practically infeasible. We have created a publicly available dataset where the ground truth sickness levels were densely marked every 0.5 seconds and adjusted/updated on-demand using the FMS, and purposely excluded the difficult-to-collect physiological data. We demonstrate that predictive models trained with such a dataset, comprising just the content motion profile and FMSdata, can still produce comparably reliable sickness prediction, and more so, when user-specific parameters (e.g., age, gender) are added. The created dataset is available at https://github.com/pvtryan1024/2025_Cybersickness_dataset.
- Open Access
- 9 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-2
Sickness Reduction in FPV Drone Control: Improved Effects of Reverse Optical Flow with Static Landmarks Only
Drones are controlled remotely through the on-board live camera often using a headset to immersively (without external distraction) situate the drone operator with a first-person view. The highly dynamic imagery of drone piloting can elicit significant VR sickness. In this poster, we demonstrate the application of mixing the reverse optical flow pattern into the drone piloting imagery for mitigating VR sickness, using only the features of the static landmarks in the scene. We compare it to the cases of applying no mitigation technique (baseline) and mixing in the optical flow pattern from “all” object features. The results show that the suggested method was significantly more effective in reducing sickness than when considering all object features, and had a higher preference for improved visibility and controllability.
- 9 October 2023
- Published by Association for Computing Machinery (ACM)
- p. 1-2
Open AccessSickness Reduction in FPV Drone Control: Improved Effects of Reverse Optical Flow with Static Landmarks Only
Drones are controlled remotely through the on-board live camera often using a headset to immersively (without external distraction) situate the drone operator with a first-person view. The highly dynamic imagery of drone piloting can elicit significant VR sickness. In this poster, we demonstrate the application of mixing the reverse optical flow pattern into the drone piloting imagery for mitigating VR sickness, using only the features of the static landmarks in the scene. We compare it to the cases of applying no mitigation technique (baseline) and mixing in the optical flow pattern from “all” object features. The results show that the suggested method was significantly more effective in reducing sickness than when considering all object features, and had a higher preference for improved visibility and controllability.
- 1 November 2006
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 568 (1) , 369-374
Development of the body scan system with backscattered X-rays
- 1 November 2006
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 568 (1) , 369-374
Development of the body scan system with backscattered X-rays