Ellen Yeats
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ellen Yeats has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Timothy L. Hall
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
4 shared publications - Jonathan R. Sukovich
Biomedical Engineering Department, University of Michigan, Ann Arbor, MI, USA
3 shared publications Timothy L. Hall
Univ. of Michigan, Ann Arbor, MI
3 shared publicationsZhen Xu
3 shared publications- Zhen Xu
Department of Biomedical Engineering, University of Michigan, Ann Arbor, USA
3 shared publications Jonathan R. Sukovich
2 shared publications
Latest Publications
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (7) , 1
Rapid, Accurate 3D Localization of Inertial Cavitation Events Using a Large Aperture, Narrowband, Receive-capable Focused Ultrasound Array
Accurate, real-time localization of cavitation events is critical for ensuring the safety and efficacy of histotripsy treatments. Current methods, such as 2-D passive acoustic mapping (PAM) and B-mode imaging, lack the necessary speed and spatial resolution for the high-treatment rates (> 100 Hz) of histotripsy. In this study, we present two computationally efficient, time-domain methods-trilateration acoustic cavitation emission (TRACE) and bandwidth-limited, large-aperture, active-acoustic, and spatio-temporal mapping (BLAST)-for rapid 3-D cavitation localization using a large-aperture, narrowband, and receive-capable focused ultrasound (US) array. TRACE estimates cavitation locations by measuring time-of-arrival (TOA) differences of cavitation collapse's shockwave emissions across an array, enabling direct localization with minimal computation. BLAST, a modified version of PAM, actively detects and time-windows collapse shockwave signals to improve processing efficiency. Experimental validation using synchronized optical imaging demonstrated submillimeter cavitation localization accuracy for both methods. TRACE achieved localization rates $\ge 100$ Hz with a computation time of 7 ms per pulse, while BLAST achieved rates exceeding 60 Hz. Results also confirmed a prefocal shift in cavitation center-of-mass relative to the array's geometric focus, highlighting the effect of focal pressure on bubble cloud dynamics. These findings suggest that TRACE and BLAST provide viable solutions for real-time 3-D cavitation monitoring, improving the precision and control of histotripsy treatments.- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics
- Vol. 73 (7) , 1
Rapid, Accurate 3D Localization of Inertial Cavitation Events Using a Large Aperture, Narrowband, Receive-capable Focused Ultrasound Array
Accurate, real-time localization of cavitation events is critical for ensuring the safety and efficacy of histotripsy treatments. Current methods, such as 2-D passive acoustic mapping (PAM) and B-mode imaging, lack the necessary speed and spatial resolution for the high-treatment rates (> 100 Hz) of histotripsy. In this study, we present two computationally efficient, time-domain methods-trilateration acoustic cavitation emission (TRACE) and bandwidth-limited, large-aperture, active-acoustic, and spatio-temporal mapping (BLAST)-for rapid 3-D cavitation localization using a large-aperture, narrowband, and receive-capable focused ultrasound (US) array. TRACE estimates cavitation locations by measuring time-of-arrival (TOA) differences of cavitation collapse's shockwave emissions across an array, enabling direct localization with minimal computation. BLAST, a modified version of PAM, actively detects and time-windows collapse shockwave signals to improve processing efficiency. Experimental validation using synchronized optical imaging demonstrated submillimeter cavitation localization accuracy for both methods. TRACE achieved localization rates $\ge 100$ Hz with a computation time of 7 ms per pulse, while BLAST achieved rates exceeding 60 Hz. Results also confirmed a prefocal shift in cavitation center-of-mass relative to the array's geometric focus, highlighting the effect of focal pressure on bubble cloud dynamics. These findings suggest that TRACE and BLAST provide viable solutions for real-time 3-D cavitation monitoring, improving the precision and control of histotripsy treatments.- Open Access
- 5 December 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (23) , 235038
Aberration correction expands the treatment envelope for histotripsy in the liver
Objective. Histotripsy is a non-invasive, non-thermal, and non-ionizing tissue ablation method based on high-amplitude pulses of focused ultrasound that has been approved by the federal Food and Drug Administration for the treatment of liver tumors. However, histotripsy currently cannot treat all locations in the liver due to attenuation of the pressure amplitude at the focus by sound-blocking ribs and air pockets and by phase aberration, or de-focusing of the ultrasound pulses by heterogeneous bodily tissues. Previous work suggests that correcting for phase aberration could increase the focal pressure to expand the treatment envelope (the treatable region) for histotripsy in the liver. The objective of this study was to investigate the effect of aberration correction on the treatment envelope. Approach . Acoustic propagation was simulated in the human body using a linear model (k-Wave) for a histotripsy phased array of similar dimensions to the current Histosonics Edison® clinical device and anatomical data from 10 subjects of varying body size. Main results . We find that aberration correction increases the focal pressure throughout the liver to substantially expand the treatment envelope (from 67% to 81% of the liver volume, on average, by linear estimations). Significance . The study suggests that aberration correction could help enable non-invasive, non-thermal histotripsy treatments for a broader patient population.
- 5 December 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (23) , 235038
Open AccessAberration correction expands the treatment envelope for histotripsy in the liver
Objective. Histotripsy is a non-invasive, non-thermal, and non-ionizing tissue ablation method based on high-amplitude pulses of focused ultrasound that has been approved by the federal Food and Drug Administration for the treatment of liver tumors. However, histotripsy currently cannot treat all locations in the liver due to attenuation of the pressure amplitude at the focus by sound-blocking ribs and air pockets and by phase aberration, or de-focusing of the ultrasound pulses by heterogeneous bodily tissues. Previous work suggests that correcting for phase aberration could increase the focal pressure to expand the treatment envelope (the treatable region) for histotripsy in the liver. The objective of this study was to investigate the effect of aberration correction on the treatment envelope. Approach . Acoustic propagation was simulated in the human body using a linear model (k-Wave) for a histotripsy phased array of similar dimensions to the current Histosonics Edison® clinical device and anatomical data from 10 subjects of varying body size. Main results . We find that aberration correction increases the focal pressure throughout the liver to substantially expand the treatment envelope (from 67% to 81% of the liver volume, on average, by linear estimations). Significance . The study suggests that aberration correction could help enable non-invasive, non-thermal histotripsy treatments for a broader patient population.
- 5 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (8) , 1019-1029
In Vivo Cavitation-Based Aberration Correction of Histotripsy in Porcine Liver
Histotripsy is a non-invasive ablation technique that focuses ultrasound pulses into the body to destroy tissues via cavitation. Heterogeneous acoustic paths through tissue introduce phase errors that distort and weaken the focus, requiring additional power output from the histotripsy transducer to perform therapy. This effect, termed phase aberration, limits the safety and efficacy of histotripsy ablation. It has been shown in vitro that the phase errors from aberration can be corrected by receiving the acoustic signals emitted by cavitation. For transabdominal histotripsy in vivo , however, cavitation-based aberration correction is complicated by acoustic signal clutter and respiratory motion. This study develops a method that enables robust, effective cavitation-based aberration correction in vivo and evaluates its efficacy in the swine liver. The method begins with a high-speed pulsing procedure to minimize the effects of respiratory motion. Then, an optimal phase correction is obtained in the presence of acoustic clutter by filtering with the singular value decomposition. This aberration correction method reduced the power required to generate cavitation in the liver by 26% on average (range: 0% to 52%) and required ~2 s for signal acquisition and processing per focus location. These results suggest that the cavitation-based method could enable fast and effective aberration correction for transabdominal histotripsy.
- 5 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (8) , 1019-1029
In Vivo Cavitation-Based Aberration Correction of Histotripsy in Porcine Liver
Histotripsy is a non-invasive ablation technique that focuses ultrasound pulses into the body to destroy tissues via cavitation. Heterogeneous acoustic paths through tissue introduce phase errors that distort and weaken the focus, requiring additional power output from the histotripsy transducer to perform therapy. This effect, termed phase aberration, limits the safety and efficacy of histotripsy ablation. It has been shown in vitro that the phase errors from aberration can be corrected by receiving the acoustic signals emitted by cavitation. For transabdominal histotripsy in vivo , however, cavitation-based aberration correction is complicated by acoustic signal clutter and respiratory motion. This study develops a method that enables robust, effective cavitation-based aberration correction in vivo and evaluates its efficacy in the swine liver. The method begins with a high-speed pulsing procedure to minimize the effects of respiratory motion. Then, an optimal phase correction is obtained in the presence of acoustic clutter by filtering with the singular value decomposition. This aberration correction method reduced the power required to generate cavitation in the liver by 26% on average (range: 0% to 52%) and required ~2 s for signal acquisition and processing per focus location. These results suggest that the cavitation-based method could enable fast and effective aberration correction for transabdominal histotripsy.
- Open Access
- 9 October 2023
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 40 (1) , 2266594
Aberration correction in abdominal histotripsy
In transabdominal histotripsy, ultrasound pulses are focused on the body to noninvasively destroy soft tissues via cavitation. However, the ability to focus is limited by phase aberration, or decorrelation of the ultrasound pulses due to spatial variation in the speed of sound throughout heterogeneous tissue. Phase aberration shifts, broadens, and weakens the focus, thereby reducing the safety and efficacy of histotripsy therapy. This paper reviews and discusses aberration effects in histotripsy and in related therapeutic ultrasound techniques (e.g., high intensity focused ultrasound), with an emphasis on aberration by soft tissues. Methods for aberration correction are reviewed and can be classified into two groups: model-based methods, which use segmented images of the tissue as input to an acoustic propagation model to predict and compensate phase differences, and signal-based methods, which use a receive-capable therapy array to detect phase differences by sensing acoustic signals backpropagating from the focus. The relative advantages and disadvantages of both groups of methods are discussed. Importantly, model-based methods can correct focal shift, while signal-based methods can restore substantial focal pressure, suggesting that both methods should be combined in a 2-step approach. Aberration correction will be critical to improving histotripsy treatments and expanding the histotripsy treatment envelope to enable non-invasive, non-thermal histotripsy therapy for more patients.
- 9 October 2023
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 40 (1) , 2266594
Open AccessAberration correction in abdominal histotripsy
In transabdominal histotripsy, ultrasound pulses are focused on the body to noninvasively destroy soft tissues via cavitation. However, the ability to focus is limited by phase aberration, or decorrelation of the ultrasound pulses due to spatial variation in the speed of sound throughout heterogeneous tissue. Phase aberration shifts, broadens, and weakens the focus, thereby reducing the safety and efficacy of histotripsy therapy. This paper reviews and discusses aberration effects in histotripsy and in related therapeutic ultrasound techniques (e.g., high intensity focused ultrasound), with an emphasis on aberration by soft tissues. Methods for aberration correction are reviewed and can be classified into two groups: model-based methods, which use segmented images of the tissue as input to an acoustic propagation model to predict and compensate phase differences, and signal-based methods, which use a receive-capable therapy array to detect phase differences by sensing acoustic signals backpropagating from the focus. The relative advantages and disadvantages of both groups of methods are discussed. Importantly, model-based methods can correct focal shift, while signal-based methods can restore substantial focal pressure, suggesting that both methods should be combined in a 2-step approach. Aberration correction will be critical to improving histotripsy treatments and expanding the histotripsy treatment envelope to enable non-invasive, non-thermal histotripsy therapy for more patients.
- Open Access
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4_suppleme) , A24
Optimizing transducer aperture subdivision for aberration correction during transabdominal histotripsy
This study investigated the effect of transducer aperture subdivision on aberration correction performance for transabdominal histotripsy. A transducer aperture and geometric curvature similar to clinical histotripsy devices (750 kHz, 20 × 16 cm width, 14 cm radius of curvature) was subdivided into 64, 256, and 1024 elements (10.7λ, 5.3λ, 2.6λ). For each of the three designs, optimal space filling (100%) equal area polygons with a pseudo-random arrangement of elements was used following the technique described by Rosnitskiy. 3D acoustic path maps were constructed from abdominal CTs of 3 de-identified human subjects and assigned acoustic properties from literature. For each transducer, acoustic transmission was simulated using k-Wave at 3 target locations in the liver of each subject with and without implementing ideal aberration correction. Across all subjects and targets (n = 9), AC increased the maximum focal pressure amplitude by 26% (0%-59%) on average for 64 elements, 38% (5%-84%) for 256 elements, and 42% (7%–92%) for 1024 elements. These results suggest 5.3λ elements may near an optimal subdivision for transabdominal histotripsy aberration correction when taking into account the cost of transducer and driving system fabrication. Acoustic simulations can save fabrication time and costs when optimizing device design.
- 1 October 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 154 (4_suppleme) , A24
Open AccessOptimizing transducer aperture subdivision for aberration correction during transabdominal histotripsy
This study investigated the effect of transducer aperture subdivision on aberration correction performance for transabdominal histotripsy. A transducer aperture and geometric curvature similar to clinical histotripsy devices (750 kHz, 20 × 16 cm width, 14 cm radius of curvature) was subdivided into 64, 256, and 1024 elements (10.7λ, 5.3λ, 2.6λ). For each of the three designs, optimal space filling (100%) equal area polygons with a pseudo-random arrangement of elements was used following the technique described by Rosnitskiy. 3D acoustic path maps were constructed from abdominal CTs of 3 de-identified human subjects and assigned acoustic properties from literature. For each transducer, acoustic transmission was simulated using k-Wave at 3 target locations in the liver of each subject with and without implementing ideal aberration correction. Across all subjects and targets (n = 9), AC increased the maximum focal pressure amplitude by 26% (0%-59%) on average for 64 elements, 38% (5%-84%) for 256 elements, and 42% (7%–92%) for 1024 elements. These results suggest 5.3λ elements may near an optimal subdivision for transabdominal histotripsy aberration correction when taking into account the cost of transducer and driving system fabrication. Acoustic simulations can save fabrication time and costs when optimizing device design.
- Open Access
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A103
In vivo soft tissue aberration correction for histotripsy using acoustic cavitation emissions
Phase aberration by heterogeneous soft tissues decreases the focusing quality of transabdominal histotripsy, thereby increasing the energy required to generate cavitation for therapy and elevating the risk of unsafe tissue heating. In vitro studies have shown that the acoustic signals emitted by histotripsy cavitation bubbles can serve as ‘point sources’ for aberration correction (AC). This study assessed the efficacy of cavitation emission-based AC in vivo. A 750-kHz, 260-element, receive-capable histotripsy phased array was used to generate cavitation at 3 locations in the livers of 3 pigs (n = 9). For each location, cavitation emission signals were received and cross correlated to determine a set of corrective phase delays. Then, the array was re-fired at increasing increments of driving power both with and without aberration correction. It was found that AC decreased the transducer power required to generate cavitation by 16%–48%. This result suggests that AC using the cavitation emissions from an initial test pulse can substantially reduce the energy delivered to intervening tissues during histotripsy therapy and thus increase treatment safety.
- 1 March 2023
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 153 (3_suppleme) , A103
Open AccessIn vivo soft tissue aberration correction for histotripsy using acoustic cavitation emissions
Phase aberration by heterogeneous soft tissues decreases the focusing quality of transabdominal histotripsy, thereby increasing the energy required to generate cavitation for therapy and elevating the risk of unsafe tissue heating. In vitro studies have shown that the acoustic signals emitted by histotripsy cavitation bubbles can serve as ‘point sources’ for aberration correction (AC). This study assessed the efficacy of cavitation emission-based AC in vivo. A 750-kHz, 260-element, receive-capable histotripsy phased array was used to generate cavitation at 3 locations in the livers of 3 pigs (n = 9). For each location, cavitation emission signals were received and cross correlated to determine a set of corrective phase delays. Then, the array was re-fired at increasing increments of driving power both with and without aberration correction. It was found that AC decreased the transducer power required to generate cavitation by 16%–48%. This result suggests that AC using the cavitation emissions from an initial test pulse can substantially reduce the energy delivered to intervening tissues during histotripsy therapy and thus increase treatment safety.
- 7 February 2023
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (5) , 1182-1193
Soft Tissue Aberration Correction for Histotripsy Using Acoustic Emissions From Cavitation Cloud Nucleation and Collapse
- 7 February 2023
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 49 (5) , 1182-1193
Soft Tissue Aberration Correction for Histotripsy Using Acoustic Emissions From Cavitation Cloud Nucleation and Collapse
- 19 July 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (15) , 155004
Effects of phase aberration on transabdominal focusing for a large aperture, low f -number histotripsy transducer
Objective . Soft tissue phase aberration may be particularly severe for histotripsy due to large aperture and low f -number transducer geometries. This study investigated how phase aberration from human abdominal tissue affects focusing of a large, strongly curved histotripsy transducer. Approach. A computational model (k-Wave) was experimentally validated with ex vivo porcine abdominal tissue and used to simulate focusing a histotripsy transducer (radius: 14.2 cm, f -number: 0.62, central frequency f c : 750 kHz) through the human abdomen. Abdominal computed tomography images from 10 human subjects were segmented to create three-dimensional acoustic property maps. Simulations were performed focusing at 3 target locations in the liver of each subject with ideal phase correction, without phase correction, and after separately matching the sound speed of water and fat to non-fat soft tissue. Main results. Experimental validation in porcine abdominal tissue showed that simulated and measured arrival time differences agreed well (average error, ∼0.10 acoustic cycles at f c ). In simulations with human tissue, aberration created arrival time differences of 0.65 μ s (∼0.5 cycles) at the target and shifted the focus from the target by 6.8 mm (6.4 mm pre-focally along depth direction), on average. Ideal phase correction increased maximum pressure amplitude by 95%, on average. Matching the sound speed of water and fat to non-fat soft tissue decreased the average pre-focal shift by 3.6 and 0.5 mm and increased pressure amplitude by 2% and 69%, respectively. Significance. Soft tissue phase aberration of large aperture, low f -number histotripsy transducers is substantial despite low therapeutic frequencies. Phase correction could potentially recover substantial pressure amplitude for transabdominal histotripsy. Additionally, different heterogeneity sources distinctly affect focusing quality. The water path strongly affects the focal shift, while irregular tissue boundaries (e.g. fat) dominate pressure loss.
- 19 July 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (15) , 155004
Effects of phase aberration on transabdominal focusing for a large aperture, low f -number histotripsy transducer
Objective . Soft tissue phase aberration may be particularly severe for histotripsy due to large aperture and low f -number transducer geometries. This study investigated how phase aberration from human abdominal tissue affects focusing of a large, strongly curved histotripsy transducer. Approach. A computational model (k-Wave) was experimentally validated with ex vivo porcine abdominal tissue and used to simulate focusing a histotripsy transducer (radius: 14.2 cm, f -number: 0.62, central frequency f c : 750 kHz) through the human abdomen. Abdominal computed tomography images from 10 human subjects were segmented to create three-dimensional acoustic property maps. Simulations were performed focusing at 3 target locations in the liver of each subject with ideal phase correction, without phase correction, and after separately matching the sound speed of water and fat to non-fat soft tissue. Main results. Experimental validation in porcine abdominal tissue showed that simulated and measured arrival time differences agreed well (average error, ∼0.10 acoustic cycles at f c ). In simulations with human tissue, aberration created arrival time differences of 0.65 μ s (∼0.5 cycles) at the target and shifted the focus from the target by 6.8 mm (6.4 mm pre-focally along depth direction), on average. Ideal phase correction increased maximum pressure amplitude by 95%, on average. Matching the sound speed of water and fat to non-fat soft tissue decreased the average pre-focal shift by 3.6 and 0.5 mm and increased pressure amplitude by 2% and 69%, respectively. Significance. Soft tissue phase aberration of large aperture, low f -number histotripsy transducers is substantial despite low therapeutic frequencies. Phase correction could potentially recover substantial pressure amplitude for transabdominal histotripsy. Additionally, different heterogeneity sources distinctly affect focusing quality. The water path strongly affects the focal shift, while irregular tissue boundaries (e.g. fat) dominate pressure loss.