Benjamin Hoar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Benjamin Hoar has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Chong Liu
University of California, Los Angeles
3 shared publications - Cyrille Costentin
Université Grenoble Alpes
3 shared publications - Hongyuan Sheng
Fudan University
3 shared publications - Quanquan Gu
University of California Los Angeles
3 shared publications Weitong Zhang
University of California, Los Angeles
3 shared publications- Jenny Y. Yang
Department of Chemistry, University of California Irvine, Irvine, USA
2 shared publications
Latest Publications
- Open Access
- 3 May 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Redox-detecting deep learning for mechanism discernment in multi-redox cyclic voltammograms
In electrochemical analysis, mechanism assignment is fundamental to understanding the chemistry of a system. The detection and classification of electrochemical mechanisms in cyclic voltammetry set the foundation for subsequent quantitative evaluation and practical application, but are often based on relatively subjective visual analyses. Deep-learning (DL) techniques provide an alternative, automated means that can support experimentalists in mechanism assignment. Herein, we present a custom DL architecture dubbed as EchemNet, capable of assigning both voltage windows and mechanism classes to electrochemical events within multi-redox cyclic voltammograms. The developed technique detects over 96% of all electrochemical events in simulated test data and shows a classification accuracy of up to 97.2% on redox events with 8 known mechanisms. This newly developed DL model, the first of its kind, proves the feasibility of redox-event detection and electrochemical mechanism classification with minimal a priori knowledge. The DL model will augment human researchers’ productivity and constitute a critical component in a general-purpose autonomous electrochemistry laboratory.
- 3 May 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessRedox-detecting deep learning for mechanism discernment in multi-redox cyclic voltammograms
In electrochemical analysis, mechanism assignment is fundamental to understanding the chemistry of a system. The detection and classification of electrochemical mechanisms in cyclic voltammetry set the foundation for subsequent quantitative evaluation and practical application, but are often based on relatively subjective visual analyses. Deep-learning (DL) techniques provide an alternative, automated means that can support experimentalists in mechanism assignment. Herein, we present a custom DL architecture dubbed as EchemNet, capable of assigning both voltage windows and mechanism classes to electrochemical events within multi-redox cyclic voltammograms. The developed technique detects over 96% of all electrochemical events in simulated test data and shows a classification accuracy of up to 97.2% on redox events with 8 known mechanisms. This newly developed DL model, the first of its kind, proves the feasibility of redox-event detection and electrochemical mechanism classification with minimal a priori knowledge. The DL model will augment human researchers’ productivity and constitute a critical component in a general-purpose autonomous electrochemistry laboratory.
- Open Access
- 26 February 2024
- Published by American Chemical Society (ACS) in ChemRxiv
What is the appropriate data representation of electrochemical impedance spectroscopy in machine-learning analysis?
Electrochemical impedance spectroscopy (EIS) is an important analytic technique for the understanding of electrochemical systems. With the recent advent and burgeoning deployment of machine learning (ML) in EIS analysis, a critical yet hitherto unanswered question emerges: what is the appropriate data representation of EIS for ML-based analysis? While the representation of a model’s input data is known to be critical for a successful deployment of ML model, EIS is known to possess multiple classical venues of data representation and it remains unclear how different EIS data should be compared following a proper data normalization protocol. Here we report the methodology and the outcomes that evaluate the efficacy of multiple data representation methods in ML-based EIS analysis. At least within our proof-of-concept parameter space, plotting the input training data’s impedance magnitude (|Z|) against phase angle (φ) while individually normalizing each EIS curve yields the highest accuracy and robustness in the correspondingly established residual neural network (ResNet) model. Rationalized by additional "importance" analysis of the input data, such a data representation method extracts information and hidden features more effectively. While Nyquist plot is more widely used in manual analysis, we found that ML-based analysis may require a different data representation and offered a clear guideline for future researchers to evaluate on a case-by-case basis.
- 26 February 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessWhat is the appropriate data representation of electrochemical impedance spectroscopy in machine-learning analysis?
Electrochemical impedance spectroscopy (EIS) is an important analytic technique for the understanding of electrochemical systems. With the recent advent and burgeoning deployment of machine learning (ML) in EIS analysis, a critical yet hitherto unanswered question emerges: what is the appropriate data representation of EIS for ML-based analysis? While the representation of a model’s input data is known to be critical for a successful deployment of ML model, EIS is known to possess multiple classical venues of data representation and it remains unclear how different EIS data should be compared following a proper data normalization protocol. Here we report the methodology and the outcomes that evaluate the efficacy of multiple data representation methods in ML-based EIS analysis. At least within our proof-of-concept parameter space, plotting the input training data’s impedance magnitude (|Z|) against phase angle (φ) while individually normalizing each EIS curve yields the highest accuracy and robustness in the correspondingly established residual neural network (ResNet) model. Rationalized by additional "importance" analysis of the input data, such a data representation method extracts information and hidden features more effectively. While Nyquist plot is more widely used in manual analysis, we found that ML-based analysis may require a different data representation and offered a clear guideline for future researchers to evaluate on a case-by-case basis.
- Open Access
- 16 October 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Autonomous closed-loop mechanistic investigation of molecular electrochemistry via automation
Electrochemical research often requires stringent combinations of experimental parameters that are demanding to manually locate. Recent advances in automated instrumentation and machine-learning algorithms unlock the possibility for accelerated studies of electrochemical fundamentals via high-throughput, online decision-making. Here we report an autonomous electrochemical platform that implements an adaptive, closed-loop workflow for mechanistic investigation of molecular electrochemistry. As a proof-of-concept, this platform autonomously identifies and investigates an EC mechanism, an interfacial electron transfer (E step) followed by a solution reaction (C step), for cobalt tetraphenylporphyrin exposed to a library of organohalide electrophiles. The generally applicable workflow accurately discerns the EC mechanism’s presence amid negative controls and outliers, adaptively designs desired experimental conditions, and quantitatively extracts kinetic information of the C step spanning over 7 orders of magnitude, from which mechanistic insights into oxidative addition pathways are gained. This work opens opportunities for autonomous mechanistic discoveries in self-driving electrochemistry laboratories without manual intervention.
- 16 October 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessAutonomous closed-loop mechanistic investigation of molecular electrochemistry via automation
Electrochemical research often requires stringent combinations of experimental parameters that are demanding to manually locate. Recent advances in automated instrumentation and machine-learning algorithms unlock the possibility for accelerated studies of electrochemical fundamentals via high-throughput, online decision-making. Here we report an autonomous electrochemical platform that implements an adaptive, closed-loop workflow for mechanistic investigation of molecular electrochemistry. As a proof-of-concept, this platform autonomously identifies and investigates an EC mechanism, an interfacial electron transfer (E step) followed by a solution reaction (C step), for cobalt tetraphenylporphyrin exposed to a library of organohalide electrophiles. The generally applicable workflow accurately discerns the EC mechanism’s presence amid negative controls and outliers, adaptively designs desired experimental conditions, and quantitatively extracts kinetic information of the C step spanning over 7 orders of magnitude, from which mechanistic insights into oxidative addition pathways are gained. This work opens opportunities for autonomous mechanistic discoveries in self-driving electrochemistry laboratories without manual intervention.