Lauren Weir
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lauren Weir has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Brandon Corbett
Sartorius Canada Inc. Oakville Ontario Canada
2 shared publicationsNigel Mathias
Department of Chemical Engineering McMaster University Hamilton Ontario Canada
2 shared publications- Prashant Mhaskar
McMaster University
2 shared publications Angus Lam
Department of Chemical Engineering, McMaster University, 1280 Main St. W., Hamilton L8S 4L7, Ontario, Canada
1 shared publicationJared Gour
Department of Chemical Engineering, McMaster University, 1280 Main St. W., Hamilton L8S 4L7, Ontario, Canada
1 shared publicationNahieli Preciado Rivera
Department of Chemical Engineering, McMaster University, 1280 Main St. W., Hamilton L8S 4L7, Ontario, Canada
1 shared publication
Latest Publications
- Open Access
- 22 October 2024
- Published by Wiley in AIChE Journal
- Vol. 71 (2)
Noise aware parameter estimation in bioprocesses: Using neural network surrogate models with nonuniform data sampling
This article demonstrates a parameter estimation technique for bioprocesses that utilizes measurement noise in experimental data to determine credible intervals on parameter estimates, with this information of potential use in prediction, robust control, and optimization. To determine these estimates, the work implements Bayesian inference using nested sampling, presenting an approach to develop neural network‐ (NN) based surrogate models. To address challenges associated with nonuniform sampling of experimental measurements, an NN structure is proposed. The resultant surrogate model is utilized within a Nested Sampling Algorithm that samples possible parameter values from the parameter space and uses the NN to calculate model output for use in the likelihood function based on the joint probability distribution of the noise of output variables. This method is illustrated against simulated data, then with experimental data from a Sartorius fed‐batch bioprocess. Results demonstrate the feasibility of the proposed technique to enable rapid parameter estimation for bioprocesses.
- 22 October 2024
- Published by Wiley in AIChE Journal
- Vol. 71 (2)
Open AccessNoise aware parameter estimation in bioprocesses: Using neural network surrogate models with nonuniform data sampling
This article demonstrates a parameter estimation technique for bioprocesses that utilizes measurement noise in experimental data to determine credible intervals on parameter estimates, with this information of potential use in prediction, robust control, and optimization. To determine these estimates, the work implements Bayesian inference using nested sampling, presenting an approach to develop neural network‐ (NN) based surrogate models. To address challenges associated with nonuniform sampling of experimental measurements, an NN structure is proposed. The resultant surrogate model is utilized within a Nested Sampling Algorithm that samples possible parameter values from the parameter space and uses the NN to calculate model output for use in the likelihood function based on the joint probability distribution of the noise of output variables. This method is illustrated against simulated data, then with experimental data from a Sartorius fed‐batch bioprocess. Results demonstrate the feasibility of the proposed technique to enable rapid parameter estimation for bioprocesses.
- Open Access
- 7 August 2024
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 103 (2) , 666-678
Leveraging neural networks to estimate parameters with confidence intervals
This manuscript presents a proof of concept for the estimation of parameters in a bioprocess while providing reliable confidence intervals. Specifically, Bayesian inference is used to estimate the uncertainty in the prediction of a parameter due to the presence of measurement noise in the process. The resultant joint probability distribution is utilized to infer the confidence interval of the resultant estimates. This method is numerically applied using a technique known as nested sampling. This algorithm iteratively samples parameters from a pre‐determined range of values to compare model predictions and obtain a probability density function. One challenge typically associated with this algorithm is in the determination of the prediction error, especially when a high‐fidelity dynamic model is being utilized. For the motivating example in the present manuscript, where a high‐fidelity simulated bioprocess is being considered, the use of the high‐fidelity model provided by Sartorius AG as part of the estimation algorithm poses computational challenges. To overcome this challenge, a universal approximator such as a parameterized neural network is used. This neural network is designed to simulate the results of the first principles model (while also capturing the dependence of the model parameters on the output), and once trained can provide near instantaneous results making the use of nested sampling computationally tractable for the application. Simulation results demonstrate the feasibility and capability of the proposed approach.
- 7 August 2024
- Published by Wiley in The Canadian Journal of Chemical Engineering
- Vol. 103 (2) , 666-678
Open AccessLeveraging neural networks to estimate parameters with confidence intervals
This manuscript presents a proof of concept for the estimation of parameters in a bioprocess while providing reliable confidence intervals. Specifically, Bayesian inference is used to estimate the uncertainty in the prediction of a parameter due to the presence of measurement noise in the process. The resultant joint probability distribution is utilized to infer the confidence interval of the resultant estimates. This method is numerically applied using a technique known as nested sampling. This algorithm iteratively samples parameters from a pre‐determined range of values to compare model predictions and obtain a probability density function. One challenge typically associated with this algorithm is in the determination of the prediction error, especially when a high‐fidelity dynamic model is being utilized. For the motivating example in the present manuscript, where a high‐fidelity simulated bioprocess is being considered, the use of the high‐fidelity model provided by Sartorius AG as part of the estimation algorithm poses computational challenges. To overcome this challenge, a universal approximator such as a parameterized neural network is used. This neural network is designed to simulate the results of the first principles model (while also capturing the dependence of the model parameters on the output), and once trained can provide near instantaneous results making the use of nested sampling computationally tractable for the application. Simulation results demonstrate the feasibility and capability of the proposed approach.
- 10 October 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (42) , 48892-48902
Injectable On-Demand Pulsatile Drug Delivery Hydrogels Using Alternating Magnetic Field-Triggered Polymer Glass Transitions
Remote-controlled pulsatile or staged release has significant potential in a wide range of therapeutic treatments. However, most current approaches are hindered by the low resolution between the on- and off-states of drug release and the need for surgical implantation of larger controlled-release devices. Herein, we describe a method that addresses these limitations by combining injectable hydrogels, superparamagnetic iron oxide nanoparticles (SPIONs) that heat when exposed to an alternating magnetic field (AMF), and polymeric nanoparticles with a glass transition temperature (Tg) just above physiological temperature. Miniemulsion polymerization was used to fabricate poly(methyl methacrylate-co-butyl methacrylate) (p(MMA-co-BMA)) nanoparticles loaded with a model hydrophobic drug and tuned to have a Tg value just above physiological temperature (∼43 °C). Co-encapsulation of these drug-loaded nanoparticles with SPIONs inside a carbohydrate-based injectable hydrogel matrix (formed by rapid hydrazone cross-linking chemistry) enables injection and immobilization of the nanoparticles at the target site. Temperature cycling facilitated a 2.5:1 to 6:1 on/off rhodamine release ratio when the nanocomposites were switched between 37 and 45 °C; release was similarly enhanced by exposing the nanocomposite hydrogel to an AMF to drive heating, with enhanced release upon pulsing observed even 1 week after injection. Coupled with the apparent cytocompatibility of all of the nanocomposite components, these injectable nanocomposite hydrogels are promising as minimally invasive but remotely actuated release delivery vehicles capable of complex release kinetics with high on-off resolution.
- 10 October 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (42) , 48892-48902
Injectable On-Demand Pulsatile Drug Delivery Hydrogels Using Alternating Magnetic Field-Triggered Polymer Glass Transitions
Remote-controlled pulsatile or staged release has significant potential in a wide range of therapeutic treatments. However, most current approaches are hindered by the low resolution between the on- and off-states of drug release and the need for surgical implantation of larger controlled-release devices. Herein, we describe a method that addresses these limitations by combining injectable hydrogels, superparamagnetic iron oxide nanoparticles (SPIONs) that heat when exposed to an alternating magnetic field (AMF), and polymeric nanoparticles with a glass transition temperature (Tg) just above physiological temperature. Miniemulsion polymerization was used to fabricate poly(methyl methacrylate-co-butyl methacrylate) (p(MMA-co-BMA)) nanoparticles loaded with a model hydrophobic drug and tuned to have a Tg value just above physiological temperature (∼43 °C). Co-encapsulation of these drug-loaded nanoparticles with SPIONs inside a carbohydrate-based injectable hydrogel matrix (formed by rapid hydrazone cross-linking chemistry) enables injection and immobilization of the nanoparticles at the target site. Temperature cycling facilitated a 2.5:1 to 6:1 on/off rhodamine release ratio when the nanocomposites were switched between 37 and 45 °C; release was similarly enhanced by exposing the nanocomposite hydrogel to an AMF to drive heating, with enhanced release upon pulsing observed even 1 week after injection. Coupled with the apparent cytocompatibility of all of the nanocomposite components, these injectable nanocomposite hydrogels are promising as minimally invasive but remotely actuated release delivery vehicles capable of complex release kinetics with high on-off resolution.