DADennis Tideman Arp

Dennis Tideman Arp

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Dennis Tideman Arp has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Defining and sparing sexual function-related organs at risk for rectal cancer radiotherapy

    by Camilla J S Kronborg, Dennis T Arp, Rana Bahij, Susan B N Biancardo, Laura V Diness, Kenni H Engstrøm, Lars U Fokdal, Bodil G Pedersen, Birgitte Havelund, Christian A Hvid, et al.

    Background and purpose: Sexual dysfunction is a common consequence of pelvic radiotherapy, influenced by psychological, physical, social, and relational factors. Research has focused on vaginal dose and stenosis in females and penile bulb dose and erectile dysfunction in males, with limited attention to domains, such as arousal, desire, and satisfaction. In the Danish Colorectal Cancer Radiotherapy Group, we aimed to: (1) Develop an atlas of sexual function-related organs at risk and (2) Evaluate if these organs at risk could be spared without compromising target coverage in rectal cancer radiotherapy planning. Patient/material and methods: A multidisciplinary approach was adopted, involving oncology, physics, psychology, surgery, and radiology. MRI-based anatomical definitions were established, and an atlas was created for both males and females, including inferior hypogastric plexus, pudendal vessels/Alcock’s canal, neurovascular bundle, penile bulb, vagina, paracolpium, and bulboclitoris. For comparative planning standard and sexual function-sparing plans were created for each patient. Results: A national consensus atlas for sexual function-related organs at risk was developed. Standard plans (n = 15) and sexual function-sparing plans (n = 15) for seven males and eight females were compared. Sparing of pudendal vessels and bulboclitoris was feasible without compromising the standard plan. For sexual function-related organs at risk in or close to the target, D2% could often be improved. Interpretation: Our consensus-based delineation and planning demonstrate that radiation dose to many sexual function-related organs at risk can be spared or optimized without compromising target coverage or dose to standard organs at risk. Future work includes implementing patient-reported outcomes and integrating these new organs at risk into standard radiotherapy planning.


  • Open Access

    Evaluating primary tumor position variation for rectal cancer patients treated with long course radiotherapy

    by Dennis Tideman Arp, Ane L Appelt, Rasa Mikalone, Martin Skovmos Nielsen, Laurids Østergaard Poulsen

    Objective. To quantify interfraction shape and positional variations of primary tumor volumes for rectal cancer patients receiving long course radiotherapy by comparing two quantification strategies: a center-of-mass (COM) method and a surface-based metric that captures local deformations. Approach. This study utilized repeat MRI scans before and during radiotherapy (RT) for rectal cancer to investigate the positional variation of the primary gross tumor volume (GTVp). Sixteen patients underwent six MRI exams, with the initial three before the RT course and the subsequent three at one, two, and four weeks into the RT course. GTVp’s were delineated on 3D T2-weighted MRIs, and positional variation analyzed using both COM and point-based surface displacements against the initial scan. Surface displacements were quantified using a bidirectional local distance measure, analyzing 3D displacement vectors. Additionally, the study examined local right–left (RL) and anterior–posterior (AP) surface variations relative to tumor height in the rectum by mapping baseline GTVp volumes onto a reference rectum structure. Main results. Systematic error for COM measurements were 1.7, 1.3 and 2.0 mm for AP, RL, and cranial–caudal (CC) direction, respectively. Random errors were 2.1, 1.2 and 2.2 mm, while the GM errors were −0.3, 0.5 and −0.3 mm for AP, RL, and CC directions, respectively. An increase in systematic and random errors were observed when comparing 95th percentile surface displacements to the COM measurements, indicating local displacements which the COM did not detect. Additionally, a general tendency for higher-located tumors to experience larger left–right and AP surface variations were seen when evaluating the 95th percentile. Significance. COM-based analysis might underestimate local deformations. Consequently, surface-based methods might provide more robust estimations of systematic, random and group mean errors for planning target volume-margin calculation. The surface variations tend to increase for tumors located in the upper part of the rectum.

  • Open Access

    Individual lymph node position variation for rectal cancer patients treated with long course chemoradiotherapy

    by Dennis Tideman Arp, Ane L. Appelt, Rasmus Froberg Brøndum, Rasa Mikalone, Martin Skovmos Nielsen, Laurids Østergaard Poulsen


  • Open Access

    Treatment planning for patients with low rectal cancer in a multicenter prospective organ preservation study

    by Dennis Tideman Arp, Ane L. Appelt, Lars Henrik Jensen, Birgitte Mayland Havelund, Henrik Dahl Nissen, Signe Lenora Risumlund, Maria Emma Eva Sjölin, Martin Skovmos Nielsen, Laurids Østergaard Poulsen


  • Geometric distortions in clinical MRI sequences for radiotherapy: insights gained from a multicenter investigation

    by Signe Winther Hasler, Jesper Folsted Kallehauge, Rasmus Hvass Hansen, Eva Samsøe, Dennis Tideman Arp, Henrik Dahl Nissen, Jens M. Edmund, Uffe Bernchou, Faisal Mahmood

    As magnetic resonance imaging (MRI) becomes increasingly integrated into radiotherapy (RT) for enhanced treatment planning and adaptation, the inherent geometric distortion in acquired MR images pose a potential challenge to treatment accuracy. This study aimed to evaluate the geometric distortion levels in the clinical MRI protocols used across Danish RT centers and discuss influence of specific sequence parameters. Based on the variety in geometric performance across centers, we assess if harmonization of MRI sequences is a relevant measure. Nine centers participated with 12 MRI scanners and MRI-Linacs (MRL). Using a travelling phantom approach, a reference MRI sequence was used to assess variation in baseline distortion level between scanners. The phantom was also scanned with local clinical MRI sequences for brain, head/neck (H/N), abdomen, and pelvis. The influence of echo time, receiver bandwidth, image weighting, and 2D/3D acquisition was investigated. We found a large variation in geometric accuracy across 93 clinical sequences examined, exceeding the baseline variation found between MRI scanners (σ = 0.22 mm), except for abdominal sequences where the variation was lower. Brain and abdominal sequences showed lowest distortion levels ([0.22, 2.26] mm), and a large variation in performance was found for H/N and pelvic sequences ([0.19, 4.07] mm). Post hoc analyses revealed that distortion levels decreased with increasing bandwidth and a less clear increase in distortion levels with increasing echo time. 3D MRI sequences had lower distortion levels than 2D (median of 1.10 and 2.10 mm, respectively), and in DWI sequences, the echo-planar imaging read-out resulted in highest distortion levels. There is a large variation in the geometric distortion levels of clinical MRI sequences across Danish RT centers, and between anatomical sites. The large variation observed makes harmonization of MRI sequences across institutions and adoption of practices from well-performing anatomical sites, a relevant measure within RT.


  • 68Ga-PSMA PET/CT compared with MRI/CT and diffusion-weighted MRI for primary lymph node staging prior to definitive radiotherapy in prostate cancer: a prospective diagnostic test accuracy study

    by Lars J. Petersen, Julie B. Nielsen, Niels C. Langkilde, Astrid Petersen, Ali Afshar-Oromieh, Nandita M. De Souza, Katja De Paepe, Rune V. Fisker, Dennis T. Arp, Jesper Carl, et al.

    Background The aim was to compare the diagnostic accuracy of 68Ga-PSMA PET/CT with conventional cross-sectional imaging and diffusion-weighted MRI (DW-MRI) for detecting lymph node metastasis (LNM) to stage prostate cancer patients. Twenty consecutive, newly- diagnosed prostate cancer patients were prospectively enrolled and underwent 68Ga-PSMA-11 PET/CT, anatomical MRI or contrast-enhanced CT, and DW-MRI prior to laparoscopic, template-based, extended lymph node dissection. Histopathological findings served as the reference test. Results Histopathology showed LNM in 13 of 20 patients (19 high-risk, 1 intermediate risk). Five patients had metastasis-suspected lymph nodes on 68Ga-PSMA PET/CT. Patient-based analysis showed that the sensitivity and specificity for detecting LNM were 39% and 100% with 68Ga-PSMA PET/CT, 8% and 100% with MRI/CT, and 36% and 83% with DW-MRI, respectively. The positive and negative predictive values were 100% and 49% with 68Ga-PSMA PET/C, 100% and 37% with MRI/CT, and 80% and 42% with DW-MRI. Of 573 dissected lymph nodes, 33 were LNM from 26 regions. True-positive LNM on 68Ga-PSMA PET/CT was 9–11 mm in diameter, whereas false-negative LNM had a median diameter of 4 mm, with only 3 of 30 lymph nodes being larger than 10 mm. LNM were positive for PSMA by immunostaining. Conclusions The sensitivity of 68Ga-PSMA PET/CT was notably better than that of MRI/CT and comparable to that of DW-MRI. Some false positive findings with DW-MRI reduced its specificity and positive predictive value compared with those of 68Ga-PSMA PET/CT and MRI/CT.


  • EXACTRACx-ray and beam isocenters-What's the difference?

    by Dennis Tideman Arp, Jesper Carl

    To evaluate the geometric accuracy of the isocenter of an image-guidance system, as implemented in the exactrac system from brainlab, relative to the linear accelerator radiation isocenter. Subsequently to correct the x-ray isocenter of the exactrac system for any geometric discrepancies between the two isocenters. Five Varian linear accelerators all equipped with electronic imaging devices and exactrac with robotics from brainlab were evaluated. A commercially available Winston-Lutz phantom and an in-house made adjustable base were used in the setup. The electronic portal imaging device of the linear accelerators was used to acquire MV-images at various gantry angles. Stereoscopic pairs of x-ray images were acquired using the exactrac system. The deviation between the position of the external laser isocenter and the exactrac isocenter was evaluated using the commercial software of the exactrac system. In-house produced software was used to analyze the MV-images and evaluate the deviation between the external laser isocenter and the radiation isocenter of the linear accelerator. Subsequently, the deviation between the radiation isocenter and the isocenter of the exactrac system was calculated. A new method of calibrating the isocenter of the exactrac system was applied to reduce the deviations between the radiation isocenter and the exactrac isocenter. To evaluate the geometric accuracy a 3D deviation vector was calculated for each relative isocenter position. The 3D deviation between the external laser isocenter and the isocenter of the exactrac system varied from 0.21 to 0.42 mm. The 3D deviation between the external laser isocenter and the linac radiation isocenter ranged from 0.37 to 0.83 mm. The 3D deviation between the radiation isocenter and the isocenter of the exactrac system ranged from 0.31 to 1.07 mm. Using the new method of calibrating the exactrac isocenter the 3D deviation of one linac was reduced from 0.90 to 0.23 mm. The results were complicated due to routine maintenance of the linac, including laser calibration. It was necessary to repeat the measurements in order to perform the calibration of the exactrac isocenter. The deviations between the linac radiation isocenter and the exactrac isocenter were of an order that may have clinical relevance. An alternative method of calibrating the isocenter of the exactrac system was applied and reduced the deviations between the two isocenters.