N. V. Khomutov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
N. V. Khomutov has a total of 373 co-authors. Here are the top co-authors by number of shared publications:
- A. Chapelain
Cornell University
2 shared publications - A. E. Tewsley-Booth
University of Kentucky
2 shared publications A. Hibbert
University of Liverpool
2 shared publications- A. Lorente Campos
University of Kentucky
2 shared publications - Aaron T. Fienberg
University of Washington
2 shared publications - Adam L. Lyon
Fermi National Accelerator Laboratory
2 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 8 August 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (3) , 032009
Detailed report on the measurement of the positive muon anomalous magnetic moment to 0.20 ppm
We present details on a new measurement of the muon magnetic anomaly, . The result is based on positive muon data taken at Fermilab’s Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses polarized muons stored in a 7.1-m-radius storage ring with a 1.45 T uniform magnetic field. The value of is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using nuclear magnetic resonance. The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure (0.21 ppm). This is the world’s most precise measurement of this quantity and represents a factor of 2.2 improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is (0.19 ppm).- 8 August 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 110 (3) , 032009
Top Cited PapersOpen AccessDetailed report on the measurement of the positive muon anomalous magnetic moment to 0.20 ppm
We present details on a new measurement of the muon magnetic anomaly, . The result is based on positive muon data taken at Fermilab’s Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses polarized muons stored in a 7.1-m-radius storage ring with a 1.45 T uniform magnetic field. The value of is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using nuclear magnetic resonance. The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure (0.21 ppm). This is the world’s most precise measurement of this quantity and represents a factor of 2.2 improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is (0.19 ppm). - Top Cited PapersOpen Access
- 17 October 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (16) , 161802
Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
We present a new measurement of the positive muon magnetic anomaly, , from the Fermilab Muon Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, , and of the anomalous precession frequency corrected for beam dynamics effects, . From the ratio , together with precisely determined external parameters, we determine (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain (0.20 ppm). The new experimental world average is (0.19 ppm), which represents a factor of 2 improvement in precision.- 17 October 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 131 (16) , 161802
Top Cited PapersOpen AccessMeasurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm
We present a new measurement of the positive muon magnetic anomaly, , from the Fermilab Muon Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, , and of the anomalous precession frequency corrected for beam dynamics effects, . From the ratio , together with precisely determined external parameters, we determine (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain (0.20 ppm). The new experimental world average is (0.19 ppm), which represents a factor of 2 improvement in precision. - 1 March 2006
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 49 (2) , 223-227
A small-power transistor divider for photomultiplier tubes
A high-voltage transistor voltage divider for photomultiplier tubes consists of a high-resistance linear resistive divider specifying potential distributions between dynodes and emitter followers maintaining this distribution. The divider features a low dissipation power and stable gain of the photomultiplier tube, when the average anode current varies in the entire measurement range.
- 1 March 2006
- Published by Pleiades Publishing Ltd in Instruments and Experimental Techniques
- Vol. 49 (2) , 223-227
A small-power transistor divider for photomultiplier tubes
A high-voltage transistor voltage divider for photomultiplier tubes consists of a high-resistance linear resistive divider specifying potential distributions between dynodes and emitter followers maintaining this distribution. The divider features a low dissipation power and stable gain of the photomultiplier tube, when the average anode current varies in the entire measurement range.