TCTy A. Cashen

Ty A. Cashen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ty A. Cashen has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Free‐breathing phase‐sensitive inversion recovery T 1 ‐weighted imaging for improved visualization of focal liver lesions

    by Yavuz Muslu, Julius F. Heidenreich, Jan‐Peter Grunz, Ty A. Cashen, Sagar Mandava, Ali Pirasteh, Diego Hernando, Scott B. Reeder

    Purpose: Gadoxetic acid‐enhanced hepatobiliary phase T 1 ‐weighted (T 1 w) MRI is effective for the detection of focal liver lesions but lacks sufficient T 1 contrast to distinguish benign from malignant lesions. Although the addition of T 2 , diffusion, and dynamic contrast‐enhanced T 1 w imaging improves lesion characterization, these methods often do not provide adequate spatial resolution to identify subcentimeter lesions. This work proposes a high‐resolution, volumetric, free‐breathing liver MRI method that produces colocalized fat‐suppressed, variable T 1 w images from a single acquisition, thereby improving both lesion detection and characterization. Theory and Methods: This method combines stack‐of‐stars radial sampling, magnetization preparation, and chemical shift encoding to enable free‐breathing, T 1 w imaging with water/fat separation. A model‐based image reconstruction algorithm reconstructs images from highly undersampled k‐space data. Pseudo‐T 1 relaxation maps are calculated from the variable T 1 w images. The feasibility of this method was investigated in patients undergoing clinical contrast‐enhanced MRI examinations for detection and characterization of focal liver lesions at both 1.5 and 3.0 T. An expert reader study was conducted to evaluate the method's performance, compared with the hepatobiliary phase‐navigated T 1 w MRI based on image quality and lesion conspicuity. Results: Expert readers found that at shorter inversion times (TIs) (˜500 ms), the proposed method had superior liver–lesion contrast for characterizing simple cysts and metastases, compared with navigated T 1 w images. Conclusion: The proposed method produces colocalized fat‐suppressed, variable T 1 w images from a single acquisition that may improve focal liver lesion detection and characterization.


  • Open Access

    Free‐breathing, fat‐corrected T1 mapping of the liver with stack‐of‐stars MRI, and joint estimation of T1, PDFF, R2*, and B1+

    by Yavuz Muslu, Daiki Tamada, Nathan T. Roberts, Ty A. Cashen, Sagar Mandava, Steven R. Kecskemeti, Diego Hernando, Scott B. Reeder

    Purpose: Quantitative T1 mapping has the potential to replace biopsy for noninvasive diagnosis and quantitative staging of chronic liver disease. Conventional T1 mapping methods are confounded by fat and inhomogeneities, resulting in unreliable T1 estimations. Furthermore, these methods trade off spatial resolution and volumetric coverage for shorter acquisitions with only a few images obtained within a breath‐hold. This work proposes a novel, volumetric (3D), free‐breathing T1 mapping method to account for multiple confounding factors in a single acquisition.Theory and Methods: Free‐breathing, confounder‐corrected T1 mapping was achieved through the combination of non‐Cartesian imaging, magnetization preparation, chemical shift encoding, and a variable flip angle acquisition. A subspace‐constrained, locally low‐rank image reconstruction algorithm was employed for image reconstruction. The accuracy of the proposed method was evaluated through numerical simulations and phantom experiments with a T1/proton density fat fraction phantom at 3.0 T. Further, the feasibility of the proposed method was investigated through contrast‐enhanced imaging in healthy volunteers, also at 3.0 T.Results: The method showed excellent agreement with reference measurements in phantoms across a wide range of T1 values (200 to 1000 ms, slope = 0.998 (95% confidence interval (CI) [0.963 to 1.035]), intercept = 27.1 ms (95% CI [0.4 54.6]), r2 = 0.996), and a high level of repeatability. In vivo imaging studies demonstrated moderate agreement (slope = 1.099 (95% CI [1.067 to 1.132]), intercept = −96.3 ms (95% CI [−82.1 to −110.5]), r2 = 0.981) compared to saturation recovery‐based T1 maps.Conclusion: The proposed method produces whole‐liver, confounder‐corrected T1 maps through simultaneous estimation of T1, proton density fat fraction, and in a single, free‐breathing acquisition and has excellent agreement with reference measurements in phantoms.


  • Open Access

    Evaluation of a Deep Learning Reconstruction for High-Quality T2-Weighted Breast Magnetic Resonance Imaging

    by Timothy J. Allen, Leah C. Henze Bancroft, Orhan Unal, Lloyd D. Estkowski, Ty A. Cashen, Frank Korosec, Roberta M. Strigel, Frederick Kelcz, Amy M. Fowler, Alison Gegios, et al.

    Deep learning (DL) reconstruction techniques to improve MR image quality are becoming commercially available with the hope that they will be applicable to multiple imaging application sites and acquisition protocols. However, before clinical implementation, these methods must be validated for specific use cases. In this work, the quality of standard-of-care (SOC) T2w and a high-spatial-resolution (HR) imaging of the breast were assessed both with and without prototype DL reconstruction. Studies were performed using data collected from phantoms, 20 retrospectively collected SOC patient exams, and 56 prospectively acquired SOC and HR patient exams. Image quality was quantitatively assessed via signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and edge sharpness. Qualitatively, all in vivo images were scored by either two or four radiologist readers using 5-point Likert scales in the following categories: artifacts, perceived sharpness, perceived SNR, and overall quality. Differences in reader scores were tested for significance. Reader preference and perception of signal intensity changes were also assessed. Application of the DL resulted in higher average SNR (1.2–2.8 times), CNR (1.0–1.8 times), and image sharpness (1.2–1.7 times). Qualitatively, the SOC acquisition with DL resulted in significantly improved image quality scores in all categories compared to non-DL images. HR acquisition with DL significantly increased SNR, sharpness, and overall quality compared to both the non-DL SOC and the non-DL HR images. The acquisition time for the HR data only required a 20% increase compared to the SOC acquisition and readers typically preferred DL images over non-DL counterparts. Overall, the DL reconstruction demonstrated improved T2w image quality in clinical breast MRI.


  • Open Access

    Radial sliding‐window magnetic resonance angiography (MRA) with highly‐constrained projection reconstruction (HYPR)

    by Hyun J. Jeong, Ty A. Cashen, Michael C. Hurley, Christopher Eddleman, Christopher Getch, H. Hunt Batjer, Timothy J. Carroll

    Sufficient temporal resolution is required to image the dynamics of blood flow, which may be critical for accurate diagnosis and treatment of various intracranial vascular diseases, such as arteriovenous malformations (AVMs) and aneurysms. Highly‐constrained projection reconstruction (HYPR) has recently become a technique of interest for high‐speed contrast‐enhanced magnetic resonance angiography (CE‐MRA). HYPR provides high frame rates by preferential weighting of radial projections while maintaining signal‐to‐noise ratio (SNR) by using a high SNR composite. An analysis was done to quantify the effects of HYPR on SNR, contrast‐to‐noise ratio (CNR), and temporal blur compared to the previously developed radial sliding‐window technique using standard filtered backprojection or regridding methods. Computer simulations were performed to study the effects of HYPR processing on image error and the temporal information. Additionally, in vivo imaging was done on patients with angiographically confirmed AVMs to measure the effects of alteration of various HYPR parameters on SNR as well as the fidelity of the temporal information. The images were scored by an interventional radiologist in a blinded read and were compared with X‐ray digital subtraction angiography (DSA). It was found that with the right choice of parameters, modest improvements in both SNR and dynamic information can be achieved as compared to radial sliding‐window MRA. Magn Reson Med, 2009.


  • Renal Artery Stenosis in Swine: Feasibility of MR Assessment of Renal Function during Percutaneous Transluminal Angioplasty

    by Jonathan K. Park, Thomas K. Rhee, Ty A. Cashen, Wanyong Shin, Brian E. Schirf, James A. Gehl, Andrew C. Larson, Pottumarthi V. Prasad, Debiao Li, Timothy J. Carroll, et al.

    To prospectively test--in a swine model of renal artery stenosis (RAS)--the hypothesis that magnetic resonance (MR) imaging can reveal changes in renal function at the time of percutaneous transluminal angioplasty (PTA). In this animal care and use committee-approved study, high-grade unilateral RAS was surgically induced in six pigs. MR imaging at 3.0 T was used for intraprocedural assessment of the anatomic and physiologic changes induced by x-ray-guided PTA. With use of MR imaging, changes in single-kidney glomerular filtration rate, extraction fraction, and renal blood flow were assessed during PTA. The arterial diameter of stenosis before and after PTA was assessed by using conventional digital subtraction angiography. Mean changes in functional and anatomic parameters were compared by using the Wilcoxon signed rank test (alpha = .05). At digital subtraction angiography, the mean percentage of stenosis was 69% +/- 10 (standard deviation) before PTA and 26% +/- 10 after PTA (P<.03). Mean pre- and post-PTA extraction fraction values were 0.11 +/- 0.03 and 0.19 +/- 0.06, respectively (P<.03). The mean single-kidney glomerular filtration rate before PTA, 19 mL/min +/- 13, increased to 41 mL/min +/- 33 after PTA (P<.03). There was no significant change in mean renal blood flow after PTA (P=.44). In swine, MR imaging can reveal changes in renal function after x-ray-guided PTA for unilateral RAS.