Jiří Vitouš
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jiří Vitouš has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Radovan Jirik
Institute of Scientific Instruments Czech Academy of Sciences Brno Czechia
6 shared publications - Ondřej Macíček
Institute of Scientific Instruments Czech Academy of Sciences Brno Czechia
4 shared publications - Zenon Starčuk
Institute of Scientific Instruments Czech Academy of Sciences Brno Czechia
4 shared publications - Eva Drazanova
Institute of Scientific Instruments of the Czech Academy of Sciences
2 shared publications - Lucie Kratka
Institute of Scientific Instruments Czech Academy of Sciences Brno Czechia
2 shared publications Ali Nabavizadeh
Department of Radiology, Perelman School of Medicine University of Pennsylvania Philadelphia Pennsylvania USA
1 shared publication
Latest Publications
- Open Access
- 2 October 2026
- Published by Wiley in Magnetic Resonance in Medicine
Optimization of Gradient Pulse Shape Prediction Using Temporal Convolutional Networks
Purpose: To improve TCN‐based gradient‐waveform prediction with respect to acquisition efficiency and inference speed, and to evaluate its use for radial imaging. Methods: Gradient waveforms were measured using a thin‐slice method on a preclinical MRI system. Separate TCN models were trained for each physical gradient axis to predict both gradient and terms. The framework was evaluated using phantom and in vivo radial acquisitions across a range of receiver bandwidths and compared with measured trajectories and gradient impulse response function (GIRF)‐based trajectory predictions. Results: The proposed workflow reduced model complexity and substantially improved prediction speed. In phantom and in vivo radial imaging, model‐based trajectories provided better image quality over a wider range of receiver bandwidths than GIRF‐based trajectories. term estimation provided limited additional visual benefit after scanner preemphasis adjustment. Conclusion: TCN‐based prediction of gradient‐waveform distortions can be made more efficient while remaining effective for radial MRI trajectory estimation on the studied preclinical system, particularly in demanding high‐bandwidth acquisitions.
- 2 October 2026
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessOptimization of Gradient Pulse Shape Prediction Using Temporal Convolutional Networks
Purpose: To improve TCN‐based gradient‐waveform prediction with respect to acquisition efficiency and inference speed, and to evaluate its use for radial imaging. Methods: Gradient waveforms were measured using a thin‐slice method on a preclinical MRI system. Separate TCN models were trained for each physical gradient axis to predict both gradient and terms. The framework was evaluated using phantom and in vivo radial acquisitions across a range of receiver bandwidths and compared with measured trajectories and gradient impulse response function (GIRF)‐based trajectory predictions. Results: The proposed workflow reduced model complexity and substantially improved prediction speed. In phantom and in vivo radial imaging, model‐based trajectories provided better image quality over a wider range of receiver bandwidths than GIRF‐based trajectories. term estimation provided limited additional visual benefit after scanner preemphasis adjustment. Conclusion: TCN‐based prediction of gradient‐waveform distortions can be made more efficient while remaining effective for radial MRI trajectory estimation on the studied preclinical system, particularly in demanding high‐bandwidth acquisitions.
- Open Access
- 12 June 2026
- Published by Wiley in Magnetic Resonance in Medicine
Blind Estimation Versus Direct Measurement of the Arterial Input Function in Dynamic Contrast‐Enhanced MRI of the Breast
Purpose: Accurate arterial input functions (AIFs) are essential for quantitative dynamic contrast‐enhanced (DCE) MRI, yet direct measurement is challenging and population‐averaged AIFs neglect patient‐specific variability. Blind deconvolution provides an alternative by estimating patient‐specific AIFs directly from tissue data, up to a scale factor. This study compared blindly estimated AIFs with carefully measured aortic AIFs in breast DCE‐MRI. Theory and Methods: Data from 25 patients with breast cancer were analyzed, each with a carefully measured AIF. Blind AIF estimates were obtained using model‐constrained deconvolution in the Perflab toolkit with both Tofts–Kety (TK) and two‐compartment exchange (2CXM) tissue models. To help isolate AIF shape blind AIFs were scaled using cardiac output. These blind AIFs were compared with measured AIFs using scale‐invariant and scale‐dependent metrics which assess the similarity of the AIF shape. Results: Blind estimates were obtained for all 25 patients with both tissue models. Compared with measured AIFs, blind estimates derived using the 2CXM showed stronger agreement across all metrics than those derived using the TK model. However, the weak correlation in scale‐dependent metrics suggests limitations of cardiac output scaling. Conclusion: Blind AIF estimation using the 2CXM provides more reliable recovery of AIF shape and dispersion than the TK model in breast DCE‐MRI. While blind deconvolution shows promise for estimating local patient‐specific AIFs other scaling strategies may need to be employed in practice.
- 12 June 2026
- Published by Wiley in Magnetic Resonance in Medicine
Open AccessBlind Estimation Versus Direct Measurement of the Arterial Input Function in Dynamic Contrast‐Enhanced MRI of the Breast
Purpose: Accurate arterial input functions (AIFs) are essential for quantitative dynamic contrast‐enhanced (DCE) MRI, yet direct measurement is challenging and population‐averaged AIFs neglect patient‐specific variability. Blind deconvolution provides an alternative by estimating patient‐specific AIFs directly from tissue data, up to a scale factor. This study compared blindly estimated AIFs with carefully measured aortic AIFs in breast DCE‐MRI. Theory and Methods: Data from 25 patients with breast cancer were analyzed, each with a carefully measured AIF. Blind AIF estimates were obtained using model‐constrained deconvolution in the Perflab toolkit with both Tofts–Kety (TK) and two‐compartment exchange (2CXM) tissue models. To help isolate AIF shape blind AIFs were scaled using cardiac output. These blind AIFs were compared with measured AIFs using scale‐invariant and scale‐dependent metrics which assess the similarity of the AIF shape. Results: Blind estimates were obtained for all 25 patients with both tissue models. Compared with measured AIFs, blind estimates derived using the 2CXM showed stronger agreement across all metrics than those derived using the TK model. However, the weak correlation in scale‐dependent metrics suggests limitations of cardiac output scaling. Conclusion: Blind AIF estimation using the 2CXM provides more reliable recovery of AIF shape and dispersion than the TK model in breast DCE‐MRI. While blind deconvolution shows promise for estimating local patient‐specific AIFs other scaling strategies may need to be employed in practice.
- Open Access
- 18 February 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (6) , 2610-2622
Focused ultrasound–induced blood–brain barrier opening: A comparative analysis of permeability quantification based on Ktrans and PS
Purpose: Focused ultrasound‐induced blood–brain barrier (BBB) opening is a promising method for neurotherapeutic delivery. The standard for quantifying induced BBB permeability is the parameter, which reflects both permeability and plasma flow. The influence of plasma flow can be eliminated by estimating the PS parameter. However, this parameter has been largely unexplored in this application. This study aims to compare permeability estimates based on and PS in focused ultrasound–induced BBB opening experiments. Methods: We used the extended Tofts model (ETM) and the two‐compartment exchange model (2CXM) to estimate and PS parameters, respectively. Permeability estimates were compared using simulated concentration curves, simulated DCE‐MRI data, and real datasets. We explored the influence of spatially‐regularized model fitting on the results. Results: For opened BBB, was minimally influenced by plasma flow under the tested conditions. However, fitting the ETM often introduced outliers in estimates in regions with closed BBB. The 2CXM outperformed the ETM at high signal‐to‐noise ratios, but its higher complexity led to lower precision at low signal‐to‐noise ratios. Both these issues were successfully compensated by spatially‐regularized model fitting. Conclusion: Both and PS seem to be eligible options for the quantification of BBB opening, and the correct choice depends on the specifics of the acquired DCE‐MRI data. Additionally, spatial regularization has demonstrated its importance in enhancing the accuracy and reproducibility of results for both models.
- 18 February 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (6) , 2610-2622
Open AccessFocused ultrasound–induced blood–brain barrier opening: A comparative analysis of permeability quantification based on Ktrans and PS
Purpose: Focused ultrasound‐induced blood–brain barrier (BBB) opening is a promising method for neurotherapeutic delivery. The standard for quantifying induced BBB permeability is the parameter, which reflects both permeability and plasma flow. The influence of plasma flow can be eliminated by estimating the PS parameter. However, this parameter has been largely unexplored in this application. This study aims to compare permeability estimates based on and PS in focused ultrasound–induced BBB opening experiments. Methods: We used the extended Tofts model (ETM) and the two‐compartment exchange model (2CXM) to estimate and PS parameters, respectively. Permeability estimates were compared using simulated concentration curves, simulated DCE‐MRI data, and real datasets. We explored the influence of spatially‐regularized model fitting on the results. Results: For opened BBB, was minimally influenced by plasma flow under the tested conditions. However, fitting the ETM often introduced outliers in estimates in regions with closed BBB. The 2CXM outperformed the ETM at high signal‐to‐noise ratios, but its higher complexity led to lower precision at low signal‐to‐noise ratios. Both these issues were successfully compensated by spatially‐regularized model fitting. Conclusion: Both and PS seem to be eligible options for the quantification of BBB opening, and the correct choice depends on the specifics of the acquired DCE‐MRI data. Additionally, spatial regularization has demonstrated its importance in enhancing the accuracy and reproducibility of results for both models.
- Open Access
- 22 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (3) , 1285-1297
Two‐parametric prescan calibration of gradient‐induced sampling errors for rosette MRI
Purpose: The aim of this study was to develop a simple, robust, and easy‐to‐use calibration procedure for correcting misalignments in rosette MRI k‐space sampling, with the objective of producing images with minimal artifacts.Methods: Quick automatic calibration scans were proposed for the beginning of the measurement to collect information on the time course of the rosette acquisition trajectory. A two‐parameter model was devised to match the measured time‐varying readout gradient delays and approximate the actual rosette sampling trajectory. The proposed calibration approach was implemented, and performance assessment was conducted on both phantoms and human subjects.Results: The fidelity of phantom and in vivo images exhibited significant improvement compared with uncorrected rosette data. The two‐parameter calibration approach also demonstrated enhanced precision and reliability, as evidenced by quantitative relaxometry analyses.Conclusion: Adequate correction of data sampling is a crucial step in rosette MRI. The presented experimental results underscore the robustness, ease of implementation, and suitability for routine experimental use of the proposed two‐parameter rosette trajectory calibration approach.
- 22 October 2024
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 93 (3) , 1285-1297
Open AccessTwo‐parametric prescan calibration of gradient‐induced sampling errors for rosette MRI
Purpose: The aim of this study was to develop a simple, robust, and easy‐to‐use calibration procedure for correcting misalignments in rosette MRI k‐space sampling, with the objective of producing images with minimal artifacts.Methods: Quick automatic calibration scans were proposed for the beginning of the measurement to collect information on the time course of the rosette acquisition trajectory. A two‐parameter model was devised to match the measured time‐varying readout gradient delays and approximate the actual rosette sampling trajectory. The proposed calibration approach was implemented, and performance assessment was conducted on both phantoms and human subjects.Results: The fidelity of phantom and in vivo images exhibited significant improvement compared with uncorrected rosette data. The two‐parameter calibration approach also demonstrated enhanced precision and reliability, as evidenced by quantitative relaxometry analyses.Conclusion: Adequate correction of data sampling is a crucial step in rosette MRI. The presented experimental results underscore the robustness, ease of implementation, and suitability for routine experimental use of the proposed two‐parameter rosette trajectory calibration approach.
- Open Access
- 19 December 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (5) , 1803-1821
The ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge
Purpose: has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.Methods: A framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.Results: Across the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.Conclusions: This study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.
- 19 December 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (5) , 1803-1821
Open AccessThe ISMRM Open Science Initiative for Perfusion Imaging (OSIPI): Results from the OSIPI–Dynamic Contrast‐Enhanced challenge
Purpose: has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging–Dynamic Contrast‐Enhanced (OSIPI‐DCE) challenge was designed to benchmark methods to better help the efforts to standardize measurement.Methods: A framework was created to evaluate values produced by DCE‐MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' values, the applied software, and a standard operating procedure. These were evaluated using the proposed score defined with accuracy, repeatability, and reproducibility components.Results: Across the 10 received submissions, the score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0–1 = lowest–highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility.Conclusions: This study reports results from the OSIPI‐DCE challenge and highlights the high inter‐software variability within estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real‐world clinical setting, many of these tools may perform differently with different benchmarking methodology.
- Open Access
- 9 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 368-380
T1 mapping of myocardium in rats using self‐gated golden‐angle acquisition
Purpose: The aim of this study is to design a method of myocardial T1 quantification in small laboratory animals and to investigate the effects of spatiotemporal regularization and the needed acquisition duration.Methods: We propose a compressed‐sensing approach to T1 quantification based on self‐gated inversion‐recovery radial two/three‐dimensional (2D/3D) golden‐angle stack‐of‐stars acquisition with image reconstruction performed using total‐variation spatiotemporal regularization. The method was tested on a phantom and on a healthy rat, as well as on rats in a small myocardium‐remodeling study.Results: The results showed a good match of the T1 estimates with the results obtained using the ground‐truth method on a phantom and with the literature values for rats myocardium. The proposed 2D and 3D methods showed significant differences between normal and remodeling myocardium groups for acquisition lengths down to approximately 5 and 15 min, respectively.Conclusions: A new 2D and 3D method for quantification of myocardial T1 in rats was proposed. We have shown the capability of both techniques to distinguish between normal and remodeling myocardial tissue. We have shown the effects of image‐reconstruction regularization weights and acquisition length on the T1 estimates.
- 9 October 2023
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 91 (1) , 368-380
Open AccessT1 mapping of myocardium in rats using self‐gated golden‐angle acquisition
Purpose: The aim of this study is to design a method of myocardial T1 quantification in small laboratory animals and to investigate the effects of spatiotemporal regularization and the needed acquisition duration.Methods: We propose a compressed‐sensing approach to T1 quantification based on self‐gated inversion‐recovery radial two/three‐dimensional (2D/3D) golden‐angle stack‐of‐stars acquisition with image reconstruction performed using total‐variation spatiotemporal regularization. The method was tested on a phantom and on a healthy rat, as well as on rats in a small myocardium‐remodeling study.Results: The results showed a good match of the T1 estimates with the results obtained using the ground‐truth method on a phantom and with the literature values for rats myocardium. The proposed 2D and 3D methods showed significant differences between normal and remodeling myocardium groups for acquisition lengths down to approximately 5 and 15 min, respectively.Conclusions: A new 2D and 3D method for quantification of myocardial T1 in rats was proposed. We have shown the capability of both techniques to distinguish between normal and remodeling myocardial tissue. We have shown the effects of image‐reconstruction regularization weights and acquisition length on the T1 estimates.