GLGa-Young Lee

Ga-Young Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ga-Young Lee has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Process Intensification for Enhanced Fluoride Removal and Recovery as Calcium Fluoride Using a Fluidized Bed Reactor

    by Arindam Sinharoy, Ga-Young Lee, Chong-Min Chung

    This study explored the feasibility of fluoride removal from simulated semiconductor industry wastewater and its recovery as calcium fluoride using fluidized bed crystallization. The continuous reactor showed the best performance (>90% fluoride removal and >95% crystallization efficiency) at a calcium-to-fluoride ratio of 0.6 within the first 40 days of continuous operation. The resulting particle size increased by more than double during this time, along with a 36% increase in the seed bed height, indicating the deposition of CaF2 onto the silica seed. The SEM-EDX analysis showed the size and shape of the crystals formed, along with the presence of a high amount of Ca-F ions. The purity of the CaF2 crystals was determined to be 91.1% though ICP-OES analysis. Following the continuous experiment, different process improvement strategies were explored. The addition of an excess amount of calcium resulted in the removal of an additional 6% of the fluoride; however, compared to this single-stage process, a two-stage approach was found to be a better strategy to achieve a low effluent concentration of fluoride. The fluoride removal reached 94% with this two-stage approach under the optimum conditions of 4 + 1 h HRT combinations and a [Ca2+]/[F−] ratio of 0.55 and 0.7 for the two reactors, respectively. CFD simulation showed the impact of the inlet diameter, bottom-angle shape, and width-to-height ratio of the reactor on the mixing inside the reactor and the possibility of further improvement in the reactor performance by optimizing the FBR configuration.


  • Open Access

    Optimization of Calcium Fluoride Crystallization Process for Treatment of High-Concentration Fluoride-Containing Semiconductor Industry Wastewater

    by Arindam Sinharoy, Ga-Young Lee, Chong-Min Chung

    This study utilized a fluidized bed reactor (FBR) for fluoride removal from high-concentration fluoride-ion-containing simulated semiconductor industry wastewater and recovered high-purity CaF2 crystals. The effects of hydraulic retention time (HRT), pH, Ca2+ to F− ratio, upflow velocity, seed size and seed bed height were investigated by performing lab-scale batch experiments. Considering fluoride removal and CaF2 crystallization efficiency, 5 h HRT, pH 6, seed height of 50 cm and [Ca2+]/[F−] ratio of 0.55 (mol/mol) were found to be optimum. The effect of the interaction between the important process parameters on fluoride removal was further analyzed using response surface methodology (RSM) experimental design. The results showed that all the individual parameters have a significant impact (p = 0.0001) on fluoride removal. SEM-EDX and FTIR analysis showed the composition of the crystals formed inside FBR. HR-XRD analysis confirmed that the crystalline structure of samples was mainly CaF2. The results clearly demonstrated the feasibility of silica seed material containing FBR for efficient removal and recovery of fluoride as high-purity calcium fluoride crystals.


  • Open Access

    Process Intensification for Enhanced Fluoride Removal and Recovery As Calcium Fluoride Using Fluidized Bed Reactor

    by Arindam Sinharoy, Ga-Young Lee, Chong Min Chung

    This study explored the feasibility of fluoride removal from simulated semiconductor industry wastewater and its recovery as calcium fluoride using fluidized bed crystallization. The continuous reactor showed best performance (>90% fluoride removal and >95% crystallization efficiency) at a calcium to fluoride ratio of 0.6 within first 40 days of continuous operation. The resulting particle size increased by more than double during this time along with a 36% increase in the seed bed height indicating deposition of CaF2 onto the silica seed. The SEM-EDX analysis showed the size and shape of the crystals formed along with high amount of Ca-F ions presence. The purity of the CaF2 crystals were determined to be 91.1% though ICP-OES analysis. Following the continuous experiment, different process improvement strategies are explored. The addition of excess amount of calcium resulted in an additional 6% fluoride removal, however, compared to this single stage process, a two-stage approach was found to be better strategy to achieve a low effluent fluoride concentration. The fluoride removal reached 94% with this two-stage approach under optimum condition of 4 + 1 h HRT combinations and a [Ca2+]/[F-] ratio of 0.55 and 0.7 for the two reactors, respectively. CFD simulation showed the impact of inlet diameter, bottom-angle shape and width and height ratio of the reactor on mixing inside reactor and possibility of further improvement in reactor performance by optimizing the FBR configuration.


  • Open Access

    Synergistic Effects of Ionizing Radiation Process in the Integrated Coagulation–Sedimentation, Fenton Oxidation, and Biological Process for Treatment of Leachate Wastewater

    by Sha Liu, Arindam Sinharoy, Ga-Young Lee, Myun-Joo Lee, Byung-Cheol Lee, Chong-Min Chung

    This study evaluated the feasibility of ionizing radiation combined with coagulation–sedimentation and Fenton oxidation as a treatment method for landfill leachate. The experiments revealed a positive correlation between pollutant removal efficiency and increased ionizing radiation intensity. Remarkable pollutant removal efficiencies were achieved under ionizing radiation at 50 kGy, with a maximum of 27% removal of total organic carbon (TOC), 61% removal of total nitrogen, 51% removal of total phosphorus, and an impressive 93% removal of NO3−-N. With the addition of coagulation–sedimentation and Fenton oxidation, the treatment efficiency further increased by 33% nitrogen, 18% SCOD, and 8% phosphate. The most significant observation from the study was that for all the different treatment methods, the results were always better for leachate samples treated with ionizing radiation than for the untreated samples. Subsequently, biological treatment was applied as a post-treatment method to remove residual organic carbon and nitrogen, which found that the best removal efficiencies were only for the low salt concentration (0.5%) and the removal decreased with increasing salt concentration. These experimental results conclusively demonstrated that when treating leachate wastewater, it was more appropriate to employ physicochemical methods rather than a biological treatment, primarily due to the high salt concentration present.