Daniel Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Daniel Kim has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Frederick H. Epstein
Department of Radiology, University of Virginia, Charlottesville, Virginia
1 shared publication- Leon Axel
New York University Langone Medical Center
1 shared publication Wesley D. Gilson
Department of Radiology, University of Virginia, Charlottesville, Virginia
1 shared publication
Latest Publications
- Open Access
- 28 June 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (1) , 188-192
Increasing the signal‐to‐noise ratio in DENSE MRI by combining displacement‐encoded echoes
A new technique was developed to increase the signal‐to‐noise ratio (SNR) in displacement encoding with stimulated echoes (DENSE) MRI. This signal‐averaged DENSE (sav‐DENSE) technique is based on the SNR advantage of extracting a pair of DENSE images with uncorrelated noise from the complex complementary spatial modulation of the magnetization image, and combining them during image reconstruction. Eleven healthy volunteers were imaged at three short‐axis locations with the use of sav‐DENSE, cine DENSE, and myocardial tagging pulse sequences. In this study, sav‐DENSE increased the SNR by 15–34% as compared to cine DENSE. Circumferential strain values measured by sav‐DENSE and myocardial tagging were strongly correlated (slope = 0.95, intercept = –0.02, R = 0.92) and within the 95% limits of agreement. The breath‐hold sav‐DENSE technique yielded relatively accurate and precise quantification of 2D intramyocardial function, with a 40.2‐ms temporal resolution and a 3.5 × 3.5 mm2 spatial resolution. Magn Reson Med 52:188–192, 2004.
- 28 June 2004
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (1) , 188-192
Open AccessIncreasing the signal‐to‐noise ratio in DENSE MRI by combining displacement‐encoded echoes
A new technique was developed to increase the signal‐to‐noise ratio (SNR) in displacement encoding with stimulated echoes (DENSE) MRI. This signal‐averaged DENSE (sav‐DENSE) technique is based on the SNR advantage of extracting a pair of DENSE images with uncorrelated noise from the complex complementary spatial modulation of the magnetization image, and combining them during image reconstruction. Eleven healthy volunteers were imaged at three short‐axis locations with the use of sav‐DENSE, cine DENSE, and myocardial tagging pulse sequences. In this study, sav‐DENSE increased the SNR by 15–34% as compared to cine DENSE. Circumferential strain values measured by sav‐DENSE and myocardial tagging were strongly correlated (slope = 0.95, intercept = –0.02, R = 0.92) and within the 95% limits of agreement. The breath‐hold sav‐DENSE technique yielded relatively accurate and precise quantification of 2D intramyocardial function, with a 40.2‐ms temporal resolution and a 3.5 × 3.5 mm2 spatial resolution. Magn Reson Med 52:188–192, 2004.