ARAnita Rao

Anita Rao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anita Rao has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Reusable versus disposable absorbent pads in perioperative care: a functional and life cycle assessment

    by Desmond van Den Berg, Alexis Kuri Garcia, Zachary Miller, Benjamin D. Hatton, Anita Rao

  • Sustainable anesthesia and environmental stewardship: balancing ecological responsibility with patient safety

    by Maya McKeown, Pedrom Farid, Frances Chung, Anita Rao

    Purpose of review: This narrative review aims to summarize and assess recent research in sustainable anesthesia and patient safety. Recent findings: Recent evidence characterizing volatiles as per- and polyfluoroalkyl substances, supports transitioning towards intravenous anesthesia where clinically appropriate. Potential ecotoxicity caused by propofol is minimal, and total intravenous anesthetic techniques are safe and effective. Reusable anesthetic equipment, such as laryngeal mask airways, breathing circuits, and patient warming devices, reduces greenhouse gas emissions and does not impact patient safety when proper sanitation protocols are followed. Virtual preoperative anesthetic consultations reduce greenhouse gas emissions, and recent randomized controlled trials found no difference in the accuracy of anesthetic assessment between virtual and in-person consultations. Finally, as extreme weather events continue to increase in frequency and intensity, we highlight the importance of climate-resilient systems in anesthesia. Summary: New literature in sustainable anesthesia emphasizes the importance of transitioning to intravenous anesthesia, using reusable equipment such as patient warming devices, virtual preoperative anesthesia consultations, and climate resiliency.

  • Open Access

    Anesthetic Gases: Environmental Impacts and Mitigation Strategies for Fluranes and Nitrous Oxide

    by William A. Anderson, Anita Rao

    Anesthetic gases represent a small but significant portion of the environmental impact of health care in many countries. These compounds include several fluorocarbons commonly referred to as “fluranes”. The fluranes are greenhouse gases (GHG) with global warming potentials in the hundreds to thousands and are also PFAS compounds (per- and polyfluorinated alkyl substances) according to at least one definition. Nitrous oxide (N2O) is sometimes used as an adjunct in anesthesia, or for sedation, but has a significant stratospheric ozone depletion potential as well as GHG effects. Reducing emissions of these compounds into the environment is, therefore, a growing priority in the health care sector. Elimination or substitution of the highest impact fluranes with alternatives has been pursued with some success but limitations remain. Several emission control strategies have been developed for fluranes including adsorption onto solids, which has shown commercial promise. Catalytic decomposition methods have been pursued for N2O emission control, although mixtures of fluranes and N2O are potentially problematic for this technology. All such emission control technologies require the effective scavenging and containment of the anesthetics during use, but the limited available information suggests that fugitive emissions into the operating room may be a significant route for unmitigated losses of approximately 50% of the used fluranes into the environment. A better understanding and quantification of such fugitive emissions is needed to help minimize these releases. Further cost–benefit and techno-economic analyses are also needed to identify strategies and best practices for the future.