Елизавета Викторовна Эльберт
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Елизавета Викторовна Эльберт has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Виталина Витальевна Ножко
Федеральное государственное бюджетное учреждение «Научный центр экспертизы средств медицинского применения» Министерства здравоохранения Российской Федерации
2 shared publications - Рауза Асхатовна Волкова
Scientific Centre for Expert Evaluation of Medicinal Products
2 shared publications - A. A. Movsesyants
Scientific Centre for Expert Evaluation of Medicinal Products
1 shared publication - S. I. Dovbysh
Scientific Centre for Expert Evaluation of Medicinal Products
1 shared publication - Vadim Anatolievich Merkulov
Scientific Centre for Expert Evaluation of Medicinal Products
1 shared publication - Valentina Vladimirovna Kosenko
Scientific Centre for Expert Evaluation of Medicinal Products
1 shared publication
Latest Publications
- 5 November 2024
- Published by The Russian Academy of Sciences in Žurnal prikladnoj himii
- Vol. 97 (4) , 277-286
Оценка устойчивости методики электрофореза в полиакриламидном геле с натрия додецилсульфатом при определении молекулярной массы белков на модели интерферона альфа-2b
Оценка устойчивости методики электрофореза в полиакриламидном геле с натрия додецилсульфатом при определении молекулярной массы белков на модели интерферона альфа-2b Оценка устойчивости методики электрофореза в полиакриламидном геле с натрия додецилсульфатом при определении молекулярной массы белков на модели интерферона альфа-2b
- 5 November 2024
- Published by The Russian Academy of Sciences in Žurnal prikladnoj himii
- Vol. 97 (4) , 277-286
Оценка устойчивости методики электрофореза в полиакриламидном геле с натрия додецилсульфатом при определении молекулярной массы белков на модели интерферона альфа-2b
Оценка устойчивости методики электрофореза в полиакриламидном геле с натрия додецилсульфатом при определении молекулярной массы белков на модели интерферона альфа-2b Оценка устойчивости методики электрофореза в полиакриламидном геле с натрия додецилсульфатом при определении молекулярной массы белков на модели интерферона альфа-2b
- Open Access
- 13 September 2023
- Published by SCEEMP in Biological Products. Prevention, Diagnosis, Treatment
- Vol. 23 (3-1) , 463-473
On assessing the viral safety of individual units of the substance "Human plasma for fractionation" by nucleic acid amplification
Scientific relevance. The absence of blood-borne viruses in human plasma-derived medicinal products must be ensured by the control of raw materials and the manufacturing process.Aim. This study aimed to analyse system suitability criteria for analytical procedures to assess the viral safety of individual units of the substance "Human plasma for fractionation" in terms of the content of nucleic acids of blood-borne viruses, considering the requirements of the European Pharmacopoeia.Materials and methods. The authors analysed individual units of the substance "Human plasma for fractionation" (hereinafter, plasma). The study used the International Standards (ISs) for human immunodeficiency virus RNA, hepatitis A virus (HAV) RNA, hepatitis C virus (HCV) RNA, hepatitis B virus (HBV) DNA, and parvovirus B19 DNA, as well as nucleic acid detection kits for these viruses based on polymerase chain reaction (PCR).Results. HCV RNA was not detected in any of the eight plasma samples studied, and parvovirus B19 DNA was detected in one of the samples at a concentration not exceeding 104 IU/mL. Three tests with the corresponding ISs showed that the studied reagent kits detected HCV RNA at a concentration of 102 IU/mL and parvovirus B19 DNA (M1 genotype) at a concentration of 104 IU/mL. In additional tests that were conducted in two samples considering the requirements of the European Pharmacopoeia for the detection of HCV RNA and parvovirus B19 DNA, a new batch of reagent kit I detected the HCV RNA IS at a concentration of 102 IU/mL only in one of three replicates, which did not correspond to the claimed sensitivity of the reagent kit. HCV RNA was not detected in either replicate in one of two plasma samples spiked with the HCV RNA IS at concentrations of 102 and 103 IU/mL, possibly because of plasma inhibitory properties. The sensitivity of the reagent kits to parvovirus B19 DNA corresponded to the label claims; the study did not show any inhibitory properties of the plasma samples.Conclusions. Polymerase chain reaction testing of the viral safety of plasma intended for manufacturing medicinal products should include control samples calibrated in IU/mL. Further research and appropriate pharmacopoeial reference materials are needed to set system suitability criteria for analytical procedures using such control samples.
- 13 September 2023
- Published by SCEEMP in Biological Products. Prevention, Diagnosis, Treatment
- Vol. 23 (3-1) , 463-473
Open AccessOn assessing the viral safety of individual units of the substance "Human plasma for fractionation" by nucleic acid amplification
Scientific relevance. The absence of blood-borne viruses in human plasma-derived medicinal products must be ensured by the control of raw materials and the manufacturing process.Aim. This study aimed to analyse system suitability criteria for analytical procedures to assess the viral safety of individual units of the substance "Human plasma for fractionation" in terms of the content of nucleic acids of blood-borne viruses, considering the requirements of the European Pharmacopoeia.Materials and methods. The authors analysed individual units of the substance "Human plasma for fractionation" (hereinafter, plasma). The study used the International Standards (ISs) for human immunodeficiency virus RNA, hepatitis A virus (HAV) RNA, hepatitis C virus (HCV) RNA, hepatitis B virus (HBV) DNA, and parvovirus B19 DNA, as well as nucleic acid detection kits for these viruses based on polymerase chain reaction (PCR).Results. HCV RNA was not detected in any of the eight plasma samples studied, and parvovirus B19 DNA was detected in one of the samples at a concentration not exceeding 104 IU/mL. Three tests with the corresponding ISs showed that the studied reagent kits detected HCV RNA at a concentration of 102 IU/mL and parvovirus B19 DNA (M1 genotype) at a concentration of 104 IU/mL. In additional tests that were conducted in two samples considering the requirements of the European Pharmacopoeia for the detection of HCV RNA and parvovirus B19 DNA, a new batch of reagent kit I detected the HCV RNA IS at a concentration of 102 IU/mL only in one of three replicates, which did not correspond to the claimed sensitivity of the reagent kit. HCV RNA was not detected in either replicate in one of two plasma samples spiked with the HCV RNA IS at concentrations of 102 and 103 IU/mL, possibly because of plasma inhibitory properties. The sensitivity of the reagent kits to parvovirus B19 DNA corresponded to the label claims; the study did not show any inhibitory properties of the plasma samples.Conclusions. Polymerase chain reaction testing of the viral safety of plasma intended for manufacturing medicinal products should include control samples calibrated in IU/mL. Further research and appropriate pharmacopoeial reference materials are needed to set system suitability criteria for analytical procedures using such control samples.