LXLei Xiao

Lei Xiao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lei Xiao has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Enhanced Sensitivity Mach–Zehnder Interferometer-Based Tapered-in-Tapered Fiber-Optic Biosensor for the Immunoassay of C-Reactive Protein

    by Lei Xiao, Xinghong Chen, Xuejin Li, Jinghan Zhang, Yan Wang, Dongqing Li, Xueming Hong, Yonghong Shao, Yuzhi Chen

    A Mach–Zehnder interferometer-based tapered-in-tapered fiber-optic biosensor was introduced in this paper. By integrating a micro-tapered fiber into a single tapered fiber structure, the design enhances sensitivity, signal-to-noise ratio, and resolution capability, while reducing the length of the sensing fiber. Through simulation analysis, it was found that the tapered-in-tapered fiber significantly improved the refractive index detection sensitivity by exciting a stronger evanescent field effect. The experimental comparison between the tapered-in-tapered fiber and traditional tapered fiber showed a 1.7-fold increase in sensitivity, reaching 3266.78 nm/RIU within the refractive index range of 1.3326 to 1.3414. Furthermore, to expand its application prospects in the biomedical field, glutaraldehyde cross-linking technology was used to immobilize C-reactive protein (CRP) antibodies on the surface of the tapered-in-tapered fiber, successfully creating a biosensing platform for the specific recognition of CRP. The experimental results demonstrate that this novel biosensor can rapidly and accurately detect CRP molecules at different concentrations with a detection limit of 0.278 μg/mL, and that it exhibits good selectivity and repeatability. This tapered-in-tapered fiber-optic biosensor provides new insights into the development of high-performance fiber-optic immunosensors and shows broad application potential in immunology research and early disease diagnosis.


  • Open Access

    Tapered Fiber Bioprobe Based on U-Shaped Fiber Transmission for Immunoassay

    by Xinghong Chen, Lei Xiao, Xuejin Li, Duo Yi, Jinghan Zhang, Hao Yuan, Zhiyao Ning, Xueming Hong, Yuzhi Chen

    In this paper, a tapered fiber bioprobe based on Mach–Zehnder interference (MZI) is proposed. To retain the highly sensitive straight-tapered fiber MZI sensing structure, we designed a U-shaped transmission fiber structure for the collection of optical sensing signals to achieve a miniature-insert-probe design. The spectrum responses from the conventional straight-tapered fiber MZI sensor and our proposed sensor were compared and analyzed, and experimental results showed that our proposed sensor not only has the same sensing capability as the straight-tapered fiber sensor, but also has the advantages of being flexible, convenient, and less liquid-consuming, which are attributed to the inserted probe design. The tapered fiber bioprobe obtained a sensitivity of 1611.27 nm/RIU in the refractive index detection range of 1.3326–1.3414. Finally, immunoassays for different concentrations of human immunoglobulin G were achieved with the tapered fiber bioprobe through surface functionalization, and the detection limit was 45 ng/mL. Our tapered fiber bioprobe has the insert-probe advantages of simpleness, convenience, and fast operation. Simultaneously, it is low-cost, highly sensitive, and has a low detection limit, which means it has potential applications in immunoassays and early medical diagnosis.