LMLongsheng Ma

Longsheng Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Longsheng Ma has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Th:SBO single crystal: A multifunction material for solid-state nuclear optical clocks

    by Lin Li, Qiaorui Gong, Yuxiang Li, Runzhe Yang, Guoliang Deng, Shanming Li, Peixiong Zhang, Chengchun Zhao, Yin Hang, Longsheng Ma, et al.

  • Investigation of the 4f146s2 1S0−4f135d6s2 (J = 2) clock transition at 431 nm of 171Yb atoms trapped in an optical lattice

    by Congyu Wang, Yuan Yao, Haosen Shi, Hongfu Yu, Longsheng Ma, Yanyi Jiang

    With the aid of an optical frequency divider based on an optical frequency comb, the frequency of a laser at 431 nm is divided from a cavity-stabilized laser at 578 nm. Using the frequency-stabilized 431 nm laser, we observe a 2.5 kHz linewidth 4f146s2 1S0−4f135d6s2 (J = 2) transition of 171Yb atoms trapped in an optical lattice. By measuring the lattice-induced frequency shift, we determine the magic wavelength of the optical lattice for the 431 nm transition to be 797.97(20) nm. The frequency of the 431 nm transition is measured to be 695 171 054 856.9(1.1) kHz by referencing to the 1S0−3P0 transition at 578 nm of Yb atoms.


  • Open Access

    Miniature narrow-linewidth 1 μm laser

    by Xiaofan Zhang, Fan Zhang, Kunpeng Jia, Yunfeng Liu, Haosen Shi, Yanyi Jiang, Xiaoshun Jiang, Longsheng Ma, Wei Liang, Zhenda Xie, et al.

    A self-injection locking scheme has the potential to narrow the linewidth of lasers in a compact setup. Here, we report a narrow linewidth laser source near 1 μm by the self-injection locking scheme using a Fabry–Pérot (FP) hollow resonator with a high-quality factor (Q > 108). The measured fundamental linewidth of the laser is 41 Hz, and a coarse tuning range over 5.5 nm is achieved by changing the driving current of the laser source. Meanwhile, a fine-tuning range of 373 MHz is achieved without mode hops by changing the voltage applied to the PZT on the resonator. More importantly, benefiting from the low thermal refractive noise and low thermal expansion of the FP hollow resonator, the beat-note linewidth and the frequency Allan deviation are measured to be 510.3 Hz in and 10−11 (1 s of averaging time), respectively, by using a fully stabilized frequency comb as a reference. Such a high-performance laser is fully integrated with a palm-sized package (52.3 ml) for field-deployable applications.


  • Open Access

    Optical frequency divider: Capable of measuring optical frequency ratio in 22 digits

    by H. Shi, Y. Jiang, Y. Yao, B. Li, C. Wang, H. Yu, L. Ma

    Recent advances in optical frequency standards and optical frequency combs (OFCs) have drawn wide attention since by transforming other quantities into frequency metrology, a higher measurement sensitivity or accuracy can be achieved. Among them, the search for dark matter, tests of relativity, and detection of gravitational wave anticipate even more precise frequency ratio measurement of optical signals, which challenges the state-of-the-art optical frequency standards and OFCs. Here, we report an optical frequency divider (OFD) based on a Ti:sapphire mode-locked laser, which can realize ultraprecise optical frequency ratio measurements and optical frequency division to other desired frequencies. The OFD is based on an OFC frequency-stabilized to a hydrogen maser, whose frequency noise in optical frequency division is subtracted via the transfer oscillator scheme. An optically referenced radio frequency time-base is introduced for the fine-tuning of the divisor and the reduction in division noise. Using the OFD, the frequency ratio between the fundamental and its second harmonic of a 1064 nm laser is measured with a fractional uncertainty of 3 × 10−22, nearly five times better than previous results. Meanwhile, we also report the ability to transport between laboratories, the long-term operation, and the multi-channel division of the OFD.