Hiromichi Fujie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hiromichi Fujie has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Norimasa Nakamura
Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
5 shared publications - Satoshi Yamakawa
Mitsubishi Electric Corporation
3 shared publications Kei Oya
School of Engineering, Tokai University
2 shared publications- Norihiko Sugita
Department of Orthopaedic Surgery, Osaka University Graduate School of Medicine, 2-2, Yamadaoka, Suita 565-0871, Japan
2 shared publications Ryosuke Nansai
Kogakuin University
2 shared publications- Seido Yarimitsu
Kyushu University
2 shared publications
Latest Publications
- Open Access
- 19 October 2023
- Published by Springer Nature in npj Regenerative Medicine
- Vol. 8 (1) , 1-14
Repair of osteochondral defects: efficacy of a tissue-engineered hybrid implant containing both human MSC and human iPSC-cartilaginous particles
Both mesenchymal stromal cells (MSC) and induced pluripotent stem cells (iPSC) offer the potential for repair of damaged connective tissues. The use of hybrid implants containing both human MSC and iPSC was investigated to assess their combined potential to yield enhanced repair of osteochondral defects. Human iPSC-CP wrapped with tissue engineered constructs (TEC) containing human MSC attained secure defect filling with good integration to adjacent tissue in a rat osteochondral injury model. The presence of living MSC in the hybrid implants was required for effective biphasic osteochondral repair. Thus, the TEC component of such hybrid implants serves several critical functions including, adhesion to the defect site via the matrix and facilitation of the repair via live MSC, as well as enhanced angiogenesis and neovascularization. Based on these encouraging studies, such hybrid implants may offer an effective future intervention for repair of complex osteochondral defects.
- 19 October 2023
- Published by Springer Nature in npj Regenerative Medicine
- Vol. 8 (1) , 1-14
Open AccessRepair of osteochondral defects: efficacy of a tissue-engineered hybrid implant containing both human MSC and human iPSC-cartilaginous particles
Both mesenchymal stromal cells (MSC) and induced pluripotent stem cells (iPSC) offer the potential for repair of damaged connective tissues. The use of hybrid implants containing both human MSC and iPSC was investigated to assess their combined potential to yield enhanced repair of osteochondral defects. Human iPSC-CP wrapped with tissue engineered constructs (TEC) containing human MSC attained secure defect filling with good integration to adjacent tissue in a rat osteochondral injury model. The presence of living MSC in the hybrid implants was required for effective biphasic osteochondral repair. Thus, the TEC component of such hybrid implants serves several critical functions including, adhesion to the defect site via the matrix and facilitation of the repair via live MSC, as well as enhanced angiogenesis and neovascularization. Based on these encouraging studies, such hybrid implants may offer an effective future intervention for repair of complex osteochondral defects.
- Open Access
- 1 June 2021
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 82 (6) , 459-466
Investigation of the effects of excessive tibial plateau angle and changes in load on ligament tensile forces in the stifle joints of dogs
OBJECTIVE: To investigate the effect of an excessive tibial plateau angle (TPA) and change in compressive load on tensile forces experienced by the cranial cruciate, medial collateral, and lateral collateral ligaments (CCL, MCL, and LCL, respectively) of canine stifle joints. SAMPLE: 16 cadaveric stifle joints from 16 orthopedically normal Beagles. PROCEDURES: Stifle joints were categorized into unchanged (mean TPA, 30.4°) and excessive (mean TPA before and after modification, 31.2° and 41.1°, respectively) TPA groups. The excessive TPA group underwent a TPA-increasing procedure (curvilinear osteotomy of the proximal aspect of the tibia) to achieve the desired TPA. A robotic system was used to apply a 30- and 60-N compressive load to specimens. The craniomedial band of the CCL, caudolateral band of the CCL, MCL, and LCL were sequentially transected; load application was repeated after each transection. Orthogonal force components were measured in situ. Forces on ligaments were calculated after repeated output force measurements as the contribution of each component was eliminated. RESULTS: Increasing the compressive load increased tensile forces on the craniomedial and caudolateral bands of the CCL, but not on the MCL or LCL, in specimens of both groups. At the 60-N load, tensile force on the craniomedial band, but not other ligaments, was greater for the excessive TPA group than for the unchanged TPA group. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that stress on the CCL may increase when the compressive load increases. The TPA-increasing procedure resulted in increased tensile force on the CCL at a 60-N compressive load without affecting forces on the MCL or LCL.
- 1 June 2021
- Published by American Veterinary Medical Association (AVMA) in American Journal of Veterinary Research
- Vol. 82 (6) , 459-466
Open AccessInvestigation of the effects of excessive tibial plateau angle and changes in load on ligament tensile forces in the stifle joints of dogs
OBJECTIVE: To investigate the effect of an excessive tibial plateau angle (TPA) and change in compressive load on tensile forces experienced by the cranial cruciate, medial collateral, and lateral collateral ligaments (CCL, MCL, and LCL, respectively) of canine stifle joints. SAMPLE: 16 cadaveric stifle joints from 16 orthopedically normal Beagles. PROCEDURES: Stifle joints were categorized into unchanged (mean TPA, 30.4°) and excessive (mean TPA before and after modification, 31.2° and 41.1°, respectively) TPA groups. The excessive TPA group underwent a TPA-increasing procedure (curvilinear osteotomy of the proximal aspect of the tibia) to achieve the desired TPA. A robotic system was used to apply a 30- and 60-N compressive load to specimens. The craniomedial band of the CCL, caudolateral band of the CCL, MCL, and LCL were sequentially transected; load application was repeated after each transection. Orthogonal force components were measured in situ. Forces on ligaments were calculated after repeated output force measurements as the contribution of each component was eliminated. RESULTS: Increasing the compressive load increased tensile forces on the craniomedial and caudolateral bands of the CCL, but not on the MCL or LCL, in specimens of both groups. At the 60-N load, tensile force on the craniomedial band, but not other ligaments, was greater for the excessive TPA group than for the unchanged TPA group. CONCLUSIONS AND CLINICAL RELEVANCE: Results indicated that stress on the CCL may increase when the compressive load increases. The TPA-increasing procedure resulted in increased tensile force on the CCL at a 60-N compressive load without affecting forces on the MCL or LCL.
- 1 January 2019
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2019, J02508P
Influence of Component Configuration on Postoperative Knee Motion in Bi-Cruciate Ligament Retaining Total Knee Arthroplasty
The greatest feature of BCR-TKA is both the anterior cruciate ligament (ACL) and posterior cruciate ligament are retained while either the ACL or both the ligaments are transected in traditional TKA. However, a highly accurate component configuration is a necessity in order to maximize the remaining ligaments’ function. We performed a biomechanical investigation to evaluate the influence of component configuration on post-operative knee motion in BCR-TKA. Three fresh-frozen human cadaveric knees were evaluated using a 6 -degree-of-freedom robotic system. In accordance with the clinical procedure of measured resection technique, the size and shape of the femoral and tibial components were selected so that they matched with those of each knee (Standard) (Fig.1). Other sets of components curve also prepared by means of upsizing the posterior femoral condyle for 1 mm and 2 mm (US1 & US2), and downsizing it for 1 mm and 2 mm (DS1 & DS2), comparing to that of standard. For each TKA-treated knee, the anterior-posterior (AP) and varus-valgus (VV) laxities were measured. Results revealed that the AP laxities of all the TKA-treated groups were almost same as that of intact knee at full extension but they were much larger at all flexion angles. The AP laxity was significantly decreased with femoral condyle upsizing at 60 degree and 90 degree of flexion while it remained unchanged at full extension and 30 degree of flexion. Similar trends were observed in VV laxity except that the laxities of all the TKA-treated groups were larger at full extension and all flexion angles. It is suggested that the laxity of TKA-treated knee at flexion angles over 60 degree can be controlled by the configuration change of femoral posterior condyle.
- 1 January 2019
- Published by Japan Society of Mechanical Engineers in The Proceedings of Mechanical Engineering Congress, Japan
- Vol. 2019, J02508P
Influence of Component Configuration on Postoperative Knee Motion in Bi-Cruciate Ligament Retaining Total Knee Arthroplasty
The greatest feature of BCR-TKA is both the anterior cruciate ligament (ACL) and posterior cruciate ligament are retained while either the ACL or both the ligaments are transected in traditional TKA. However, a highly accurate component configuration is a necessity in order to maximize the remaining ligaments’ function. We performed a biomechanical investigation to evaluate the influence of component configuration on post-operative knee motion in BCR-TKA. Three fresh-frozen human cadaveric knees were evaluated using a 6 -degree-of-freedom robotic system. In accordance with the clinical procedure of measured resection technique, the size and shape of the femoral and tibial components were selected so that they matched with those of each knee (Standard) (Fig.1). Other sets of components curve also prepared by means of upsizing the posterior femoral condyle for 1 mm and 2 mm (US1 & US2), and downsizing it for 1 mm and 2 mm (DS1 & DS2), comparing to that of standard. For each TKA-treated knee, the anterior-posterior (AP) and varus-valgus (VV) laxities were measured. Results revealed that the AP laxities of all the TKA-treated groups were almost same as that of intact knee at full extension but they were much larger at all flexion angles. The AP laxity was significantly decreased with femoral condyle upsizing at 60 degree and 90 degree of flexion while it remained unchanged at full extension and 30 degree of flexion. Similar trends were observed in VV laxity except that the laxities of all the TKA-treated groups were larger at full extension and all flexion angles. It is suggested that the laxity of TKA-treated knee at flexion angles over 60 degree can be controlled by the configuration change of femoral posterior condyle.
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Kanto Branch
- Vol. 2017.23, 1505
Influence of tissue structure on mechanical properties of articular cartilage
- 1 January 2017
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Kanto Branch
- Vol. 2017.23, 1505
Influence of tissue structure on mechanical properties of articular cartilage
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Asian Pacific Conference on Biomechanics : emerging science and technology in biomechanics
- Vol. 2015.8, 90
OS4-4 Three-dimensional strain distribution in the attachment area of the anterior cruciate ligament during anterior translation to the knee(OS4: Advanced Clinical Joint Biomechanics)
- 1 January 2015
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Asian Pacific Conference on Biomechanics : emerging science and technology in biomechanics
- Vol. 2015.8, 90
OS4-4 Three-dimensional strain distribution in the attachment area of the anterior cruciate ligament during anterior translation to the knee(OS4: Advanced Clinical Joint Biomechanics)
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Kanto Branch
- Vol. 2014.20, _20216-1_
20216 Assessment of a stabilization procedure for posterior radial tear of the lateral meniscus
- 1 January 2014
- Published by Japan Society of Mechanical Engineers in The Proceedings of Conference of Kanto Branch
- Vol. 2014.20, _20216-1_
20216 Assessment of a stabilization procedure for posterior radial tear of the lateral meniscus
- Open Access
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Materials and processing conference
- Vol. 2013.21, _512-1_
512 Nanoperiodic structure of culture surface formed by femtosecond laser and the adhesive properties of mesenchymal stem cells
- 1 January 2013
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Materials and processing conference
- Vol. 2013.21, _512-1_
Open Access512 Nanoperiodic structure of culture surface formed by femtosecond laser and the adhesive properties of mesenchymal stem cells
- Open Access
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2012.24, _8A33-1_
8A33 Analysis of start-up friction behavior of articular cartilage using a fiber-reinforced poroelastic model
- 1 January 2012
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Bioengineering Conference Annual Meeting of BED/JSME
- Vol. 2012.24, _8A33-1_
Open Access8A33 Analysis of start-up friction behavior of articular cartilage using a fiber-reinforced poroelastic model
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2010.6, 229-230
J0204-2-2 Mechanical properties of cartilage-like tissue repaired with a scaffold-free, stem cell-based tissue engineered construct (TEC)
We have been developing a method of cartilage repair by means of a stem cell-based tissue engineered construct (TEC). The present study was performed to determine the coefficient of friction of cartilage-like tissue repaired with TEC. Amass of TEC was implanted into a cylindrically-shaped chondro defect created on the bearing surface of porcine femoral cartilage. Immediately and 60s after the application of compressive force, the coefficient of friction of the TEC-treated tissue was slightly decreased with the increase of load. Although, the coefficient of friction was significantly higher in the TEC-untreated tissue than in the normal cartilage immediately after the application of compressive load, no significant difference was observed as regard with coefficient of friction between the TEC-treated tissue and normal cartilage in all the conditions.
- 1 January 2010
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2010.6, 229-230
J0204-2-2 Mechanical properties of cartilage-like tissue repaired with a scaffold-free, stem cell-based tissue engineered construct (TEC)
We have been developing a method of cartilage repair by means of a stem cell-based tissue engineered construct (TEC). The present study was performed to determine the coefficient of friction of cartilage-like tissue repaired with TEC. Amass of TEC was implanted into a cylindrically-shaped chondro defect created on the bearing surface of porcine femoral cartilage. Immediately and 60s after the application of compressive force, the coefficient of friction of the TEC-treated tissue was slightly decreased with the increase of load. Although, the coefficient of friction was significantly higher in the TEC-untreated tissue than in the normal cartilage immediately after the application of compressive load, no significant difference was observed as regard with coefficient of friction between the TEC-treated tissue and normal cartilage in all the conditions.