JKJoo Sung Kim

Joo Sung Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joo Sung Kim has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The First Korean Chapter for the Small Sciences Symposium

    by Il Jeon, Dongwook Kim, Joo Sung Kim, Jin‐Woo Oh, Sang Mun Jeong, Hak Ki Yu, Hyung Do Kim

  • Pressure-Gated Ionic Contact in Multilayered Nanomeshes Enables Strain-Insensitive Pressure Sensing

    by Joo Sung Kim, Junyoung Lee, Lulu Sun, Shuxu Wang, Sangmin Chae, Rasha Bayomi, Ruiliu Wang, Younghyun Ko, Daishi Inoue, Beom Geun Ki, et al.

    Soft robotic grippers require tactile interfaces that selectively detect contact pressure at the object–gripper interface without strain-induced artifacts from gripper deformation. Here, we report an ultrathin pressure-gated ionic-contact (PGIC) sensor for multidirectional tensile strain-insensitive pressure sensing. The sensor consists of stacked ion-conductive nanomesh layers and a porous insulating nanomesh interlayer. Normal pressure locally activates ionically conductive pathways between the ionomesh layers through the porous interlayer, whereas in-plane tensile deformation is mechanically accommodated without forming these pathways. This pressure-gated architecture produces an ionic-contact-mediated capacitive response under normal pressure and negligible capacitance variation under tensile strain. The 25-μm-thick fully nanofiber-based PGIC sensor enables conformal integration with a soft jamming gripper and pressure-selective tactile mapping at the object–gripper interface under simultaneous membrane deformation. The PGIC sensor-integrated gripper achieves stable object grasping and resolves object-dependent contact patterns determined by rigidity and geometry during membrane deformation.

  • Open Access

    Bioinspired Oxygen Functional Group Density Governs Hydrovoltaic Energy Harvesting for Soil–Moisture–Driven Plant Monitoring

    by Sunmin Jang, Sumin Cho, Joo Sung Kim, Soban Ali Shah, Donghan Lee, Yu‐Seop Kim, Jisoo Oh, Kwanggyu Hyun, Sunghoon Lee, Takao Someya, et al.

    Hydrovoltaic generators convert ambient water flow into electricity, yet their power output has plateaued for lack of a quantitative link between surface chemistry and electrokinetic performance. Here we identify oxygen functional group density as that missing descriptor. The design is inspired by plant root cell walls, where oxygen‐rich ─COOH and ─OH groups electrostatically recruit mobile cations to drive nutrient uptake. We translate this chemical logic into a Cellulose‐scaffolded Oxygen‐functionalized Hydrovoltaic Generator (CO‐HyGEN), pairing a long‐fiber Hanji cellulose scaffold with a graphene oxide interface. Across a graded series of carbon architectures, physicochemical, surface‐electronic, and electrochemical signatures converge on a consistent picture: zeta potential, work function, hydrovoltaic output, and charge‐storage response exhibit systematic dependence on the oxygen functional group density. Beyond passive wettability, the oxygen‐rich graphene oxide interface behaves as an electrochemically active participant rather than an inert conduit, strengthening the electrical double layer through denser electrostatic recruitment of counterions, consistent with its more negative zeta potential and higher work function. Deployed around the root zone of a living plant, CO‐HyGEN arrays autonomously harvest soil moisture to power wireless Bluetooth sensing, demonstrating a plant‐electronics symbiosis that extends interface‐engineered hydrovoltaics toward bio‐integrated energy systems.

  • Open Access

    A body-scale textile-based electromyogram monitoring system with coaxially shielded conductive yarns

    by Sunghoon Lee, Kanta Takano, Wakako Yukita, Yusaku Tagawa, Lulu Sun, Shuxu Wang, Joo Sung Kim, Tomoyuki Yokota, Takao Someya

    A crucial aim of wearable electronics is to acquire biological signals from the body with high precision. However, obtaining high-accuracy electromyogram (EMG) signals from a large area surrounded by noise sources remains challenging. In this study, we present a body-scale textile-based wireless electromyogram monitoring system with coaxially shielded conductive yarns that can reduce the influence of surrounding noise. The wiring yarns comprise three stretchable components: a conductive signal yarn, polyurethane insulating layer, and shielding conductor. The introduction of the shielding conductor suppresses noise contamination. The noise level remains below 0.1 millivolts, despite the wiring being directly pressed at nominal contact pressures exceeding 30 kilopascals. The muscle activity at various shoulder joint angles is successfully recorded when another person directly touches the arm and wiring for support. Furthermore, EMG monitoring of the lower body is performed during dynamic activities such as countermovement jumps, jogging, and running.


  • Top Cited Papers

    Permeable Bioelectronics toward Biointegrated Systems

    by Sunghoon Lee, Xiaoping Liang, Joo Sung Kim, Tomoyuki Yokota, Kenjiro Fukuda, Takao Someya

    Bioelectronics integrates electronics with biological organs, sustaining the natural functions of the organs. Organs dynamically interact with the external environment, managing internal equilibrium and responding to external stimuli. These interactions are crucial for maintaining homeostasis. Additionally, biological organs possess a soft and stretchable nature; encountering objects with differing properties can disrupt their function. Therefore, when electronic devices come into contact with biological objects, the permeability of these devices, enabling interactions and substance exchanges with the external environment, and the mechanical compliance are crucial for maintaining the inherent functionality of biological organs. This review discusses recent advancements in soft and permeable bioelectronics, emphasizing materials, structures, and a wide range of applications. The review also addresses current challenges and potential solutions, providing insights into the integration of electronics with biological organs.


  • Open Access

    Ion trap and release dynamics enables nonintrusive tactile augmentation in monolithic sensory neuron

    by Hyukmin Kweon, Joo Sung Kim, Seongchan Kim, Haisu Kang, Dong Jun Kim, Hanbin Choi, Dong Gue Roe, Young Jin Choi, Seung Geol Lee, Jeong Ho Cho, et al.

    An iontronic-based artificial tactile nerve is a promising technology for emulating the tactile recognition and learning of human skin with low power consumption. However, its weak tactile memory and complex integration structure remain challenging. We present an ion trap and release dynamics (iTRD)–driven, neuro-inspired monolithic artificial tactile neuron (NeuroMAT) that can achieve tactile perception and memory consolidation in a single device. Through the tactile-driven release of ions initially trapped within iTRD-iongel, NeuroMAT only generates nonintrusive synaptic memory signals when mechanical stress is applied under voltage stimulation. The induced tactile memory is augmented by auxiliary voltage pulses independent of tactile sensing signals. We integrate NeuroMAT with an anthropomorphic robotic hand system to imitate memory-based human motion; the robust tactile memory of NeuroMAT enables the hand to consistently perform reliable gripping motion.