Francesco Benazzo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Francesco Benazzo has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Stefano Marco Paolo Rossi
Arthroplasty Team, Dipartimento di Ortopedia e Traumatologia, ASST Grande Ospedale Metropolitano Niguarda, Ospedale Niguarda Ca’ Granda, Milan, Italy
3 shared publications - Andrea Bernetti
Department of Experimental Medicine, University of Salento, 73100 Lecce, Italy
2 shared publications - Pier Francesco Indelli
Institute of Biomechanics, Paracelsus Medical University (PMU), 5020 Salzburg, Austria
2 shared publications Aleksandra Torbica
Research Centre on Health and Social Care Management (CERGAS), SDA Bocconi School of Management, Milan, Italy
1 shared publication- Andrea Baldini
Istituto Fiorentino di Cura e Assistenza, 50139 Florence, Italy
1 shared publication - Andrea Giordano Salvi
Department of Orthpaedic Surgery, Sudtiroler Sanitatsbertrieb, 39042 Brixen, Italy
1 shared publication
Latest Publications
- Open Access
- 17 June 2026
- Published by BioExcel in Drugs in Context
- Vol. 15, 1
Corrigendum: Rheological properties and clinical efficacy of a chemically modified hyaluronic acid for joint health enhancement
The authors wish to make the following corrections to their article: Benazzo F, Bernetti A. Rheological properties and clinical efficacy of a chemically modified hyaluronic acid for joint health enhancement. Drugs Context. 2026;15:2025-10-4. https://doi.org/10.7573/dic.2025-10-4
- 17 June 2026
- Published by BioExcel in Drugs in Context
- Vol. 15, 1
Open AccessCorrigendum: Rheological properties and clinical efficacy of a chemically modified hyaluronic acid for joint health enhancement
The authors wish to make the following corrections to their article: Benazzo F, Bernetti A. Rheological properties and clinical efficacy of a chemically modified hyaluronic acid for joint health enhancement. Drugs Context. 2026;15:2025-10-4. https://doi.org/10.7573/dic.2025-10-4
- Open Access
- 29 September 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (5) , 1740-1749
Time‐dependent wound management protocol prevents periprosthetic joint infection in total knee arthroplasty with persistent drainage
Purpose: This study aimed to evaluate the success rate of a standardised protocol for managing persistent wound drainage following total knee arthroplasty (TKA). Methods: A prospective observational study was conducted at four institutions between January and June 2022 across primary and revision TKAs. Sixty‐two patients (mean age 71.5 ± 9.3 years; 45.2% male) who experienced postoperative wound drainage after primary (58.1%) or revision (41.9%) TKA were enrolled. The protocol included staged interventions: anticoagulation adjustments and dressing changes during Days 1–3, incisional negative pressure wound therapy during Days 3–5, and wound debridement above the joint capsule if drainage persisted beyond Day 7. Outcomes were evaluated using the ASEPSIS score. The primary outcome was defined as complete wound healing without progression to debridement, antibiotics and implant retention (DAIR) procedure or periprosthetic joint infection (PJI). Results: The mean follow‐up was 13.2 months (range, 11.7–15.1 months). The protocol achieved a 91.9% success rate in preventing progression to DAIR. The median number of visits required to achieve wound healing was 3.5 for the cohort. DAIR rate was 8.1% ( n = 5), while PJI rate was 1.6% ( n = 1). Primary TKA procedures demonstrated more efficient healing trajectories compared to revision cases, requiring fewer clinical visits (median 3 vs. 5, p < 0.001) and shorter hospital stays (mean 4.5 vs. 7.5 days, p = 0.017). Cox proportional hazards model identified intervention type (revision vs. primary, hazard ratio [HR] 0.24, p < 0.001), advanced age (HR: 0.95 per year, p = 0.006), and male gender (HR: 0.45, p = 0.020) as significant independent predictors of increased time required to achieve wound healing. Conclusion: Our standardised wound management protocol achieved a high success rate in preventing progression to PJI following TKA. The time‐dependent approach to intervention escalation provides clear clinical decision‐making criteria and suggests that early identification and systematic management of wound complications are critical determinants of successful outcomes, particularly for primary TKA procedures. Level of Evidence: Level II.
- 29 September 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (5) , 1740-1749
Open AccessTime‐dependent wound management protocol prevents periprosthetic joint infection in total knee arthroplasty with persistent drainage
Purpose: This study aimed to evaluate the success rate of a standardised protocol for managing persistent wound drainage following total knee arthroplasty (TKA). Methods: A prospective observational study was conducted at four institutions between January and June 2022 across primary and revision TKAs. Sixty‐two patients (mean age 71.5 ± 9.3 years; 45.2% male) who experienced postoperative wound drainage after primary (58.1%) or revision (41.9%) TKA were enrolled. The protocol included staged interventions: anticoagulation adjustments and dressing changes during Days 1–3, incisional negative pressure wound therapy during Days 3–5, and wound debridement above the joint capsule if drainage persisted beyond Day 7. Outcomes were evaluated using the ASEPSIS score. The primary outcome was defined as complete wound healing without progression to debridement, antibiotics and implant retention (DAIR) procedure or periprosthetic joint infection (PJI). Results: The mean follow‐up was 13.2 months (range, 11.7–15.1 months). The protocol achieved a 91.9% success rate in preventing progression to DAIR. The median number of visits required to achieve wound healing was 3.5 for the cohort. DAIR rate was 8.1% ( n = 5), while PJI rate was 1.6% ( n = 1). Primary TKA procedures demonstrated more efficient healing trajectories compared to revision cases, requiring fewer clinical visits (median 3 vs. 5, p < 0.001) and shorter hospital stays (mean 4.5 vs. 7.5 days, p = 0.017). Cox proportional hazards model identified intervention type (revision vs. primary, hazard ratio [HR] 0.24, p < 0.001), advanced age (HR: 0.95 per year, p = 0.006), and male gender (HR: 0.45, p = 0.020) as significant independent predictors of increased time required to achieve wound healing. Conclusion: Our standardised wound management protocol achieved a high success rate in preventing progression to PJI following TKA. The time‐dependent approach to intervention escalation provides clear clinical decision‐making criteria and suggests that early identification and systematic management of wound complications are critical determinants of successful outcomes, particularly for primary TKA procedures. Level of Evidence: Level II.
- Open Access
- 18 July 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (3) , e70370
The HKA axis varies significantly with knee motion: A robot‐assisted intraoperative evaluation during total knee arthroplasty supports the use of dynamic, not static, alignment classifications
Purpose: New alignment classifications based on phenotype reproduction have recently been introduced in total knee arthroplasty (TKA) as alternatives to traditional mechanical alignment. These classifications were designed according to the static hip–knee–ankle angle (sHKA) measurement from long leg radiographs (LLRs). This study aimed to understand whether and how the HKA varied throughout the knee's range of motion (ROM) during robot‐assisted TKA. Methods: This prospective, bi‐centric cohort study involved 107 consecutive patients undergoing primary robot‐assisted TKA. The surgical technique adhered to restricted kinematic alignment (HKA ± 3°) with asymmetric gap balancing principles. The HKA's dynamic variation (dHKA) was assessed intraoperatively at full extension, as well as at 30°, 45°, 60°, 90° and 120°, both before bone cuts and after the positioning of the trial components. The overall cohort was initially analyzed, followed by a subgroup analysis based on varus, neutral and valgus phenotypes. A descriptive analysis was conducted to evaluate dHKA trends. Collected data were then analyzed using one‐way repeated measures analysis of variance with Bonferroni correction and Bland–Altman plots to assess significant variations in dHKA across the ROM during flexion and to quantify outliers from the established safe boundaries of ±3°. Results: Out of 107 knees, the pre‐cut dHKA demonstrated a biphasic trend, decreasing in varus until 60° and then transitioning toward valgus, with significant differences primarily noted at 90° and 120°. Post‐cut, the dHKA exhibited an overall varus trend, increasing from full extension to 60° before experiencing a partial recovery. Significant differences were detected primarily at the initial flexion angles. Outlier rates increased with flexion: pre‐cut from 6.5% to 43.0%, and post‐cut from 1.9% to 30.8%, highlighting progressive inter‐individual variability throughout. Although the analysis was stratified by knee phenotype, the post‐cut dHKA trend did not differ among the various phenotypes or in comparison to the overall cohort trend. Conclusions: The main finding of the current study was that intraoperative dHKA differs significantly from sHKA during robot‐assisted TKA. Moreover, the sHKA was limited in predicting the actual kinematic HKA. Planning the final TKA alignment on static, standing LLRs may have limited value compared to intraoperative planning conducted with enabling technologies. Level of Evidence: Level 3.
- 18 July 2025
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (3) , e70370
Open AccessThe HKA axis varies significantly with knee motion: A robot‐assisted intraoperative evaluation during total knee arthroplasty supports the use of dynamic, not static, alignment classifications
Purpose: New alignment classifications based on phenotype reproduction have recently been introduced in total knee arthroplasty (TKA) as alternatives to traditional mechanical alignment. These classifications were designed according to the static hip–knee–ankle angle (sHKA) measurement from long leg radiographs (LLRs). This study aimed to understand whether and how the HKA varied throughout the knee's range of motion (ROM) during robot‐assisted TKA. Methods: This prospective, bi‐centric cohort study involved 107 consecutive patients undergoing primary robot‐assisted TKA. The surgical technique adhered to restricted kinematic alignment (HKA ± 3°) with asymmetric gap balancing principles. The HKA's dynamic variation (dHKA) was assessed intraoperatively at full extension, as well as at 30°, 45°, 60°, 90° and 120°, both before bone cuts and after the positioning of the trial components. The overall cohort was initially analyzed, followed by a subgroup analysis based on varus, neutral and valgus phenotypes. A descriptive analysis was conducted to evaluate dHKA trends. Collected data were then analyzed using one‐way repeated measures analysis of variance with Bonferroni correction and Bland–Altman plots to assess significant variations in dHKA across the ROM during flexion and to quantify outliers from the established safe boundaries of ±3°. Results: Out of 107 knees, the pre‐cut dHKA demonstrated a biphasic trend, decreasing in varus until 60° and then transitioning toward valgus, with significant differences primarily noted at 90° and 120°. Post‐cut, the dHKA exhibited an overall varus trend, increasing from full extension to 60° before experiencing a partial recovery. Significant differences were detected primarily at the initial flexion angles. Outlier rates increased with flexion: pre‐cut from 6.5% to 43.0%, and post‐cut from 1.9% to 30.8%, highlighting progressive inter‐individual variability throughout. Although the analysis was stratified by knee phenotype, the post‐cut dHKA trend did not differ among the various phenotypes or in comparison to the overall cohort trend. Conclusions: The main finding of the current study was that intraoperative dHKA differs significantly from sHKA during robot‐assisted TKA. Moreover, the sHKA was limited in predicting the actual kinematic HKA. Planning the final TKA alignment on static, standing LLRs may have limited value compared to intraoperative planning conducted with enabling technologies. Level of Evidence: Level 3.
- Open Access
- 31 March 2025
- Published by BioExcel in Drugs in Context
- Vol. 15, 1-12
Rheological properties and clinical efficacy of a chemically modified hyaluronic acid for joint health enhancement
In this narrative review, we outline the key rheological properties of viscosupplements used for joint health and demonstrate how Hymovis/Hymovis ONE®, through MObile REticulum (MO.RE.) technology, provides effective viscoelastic and lubricating actions for joint health.
- 31 March 2025
- Published by BioExcel in Drugs in Context
- Vol. 15, 1-12
Open AccessRheological properties and clinical efficacy of a chemically modified hyaluronic acid for joint health enhancement
In this narrative review, we outline the key rheological properties of viscosupplements used for joint health and demonstrate how Hymovis/Hymovis ONE®, through MObile REticulum (MO.RE.) technology, provides effective viscoelastic and lubricating actions for joint health.
- Open Access
- 14 October 2023
- Published by SAGE Publications in Medical Decision Making
- Vol. 43 (7-8) , 886-900
Collecting Physicians’ Preferences on Medical Devices: Are We Doing It Right? Evidence from Italian Orthopedists Using 2 Different Stated Preference Methods
Objectives: Physician preference items (PPIs) are high-cost medical devices for which clinicians express firm preferences with respect to a particular manufacturer or product. This study aims to identify the most important factors in the choice of new PPIs (hip or knee prosthesis) and infer about the existence of possible response biases in using 2 alternative stated preference techniques. Methods: Six key attributes with 3 levels each were identified based on a literature review and clinical experts’ opinions. An online survey was administered to Italian hospital orthopedists using type 1 best-worst scaling (BWS) and binary discrete choice experiment (DCE). BWS data were analyzed through descriptive statistics and conditional logit model. A mixed logit regression model was applied to DCE data, and willingness-to-pay (WTP) was estimated. All analyses were conducted using Stata 16. Results: A sample of 108 orthopedists were enrolled. In BWS, the most important attribute was “clinical evidence,” followed by “quality of products,” while the least relevant items were “relationship with the sales representative” and “cost.” DCE results suggested instead that orthopedists prefer high-quality products with robust clinical evidence, positive health technology assessment recommendation and affordable cost, and for which they have a consolidated experience of use and a good relationship with the sales representative. Conclusions: The elicitation of preferences for PPIs using alternative methods can lead to different results. The BWS of type 1, which is similar to a ranking exercise, seems to be more affected by acquiescent responding and social desirability than the DCE, which introduces tradeoffs in the choice task and is likely to reveal more about true preferences. Highlights: Physician preference items (PPIs) are medical devices particularly exposed to physicians’ choice with regard to type of product and supplier. Some established techniques of collecting preferences can be affected by response biases such as acquiescent responding and social desirability. Discrete choice experiments, introducing more complex tradeoffs in the choice task, are likely to mitigate such biases and reveal true physicians’ preferences for PPIs.
- 14 October 2023
- Published by SAGE Publications in Medical Decision Making
- Vol. 43 (7-8) , 886-900
Open AccessCollecting Physicians’ Preferences on Medical Devices: Are We Doing It Right? Evidence from Italian Orthopedists Using 2 Different Stated Preference Methods
Objectives: Physician preference items (PPIs) are high-cost medical devices for which clinicians express firm preferences with respect to a particular manufacturer or product. This study aims to identify the most important factors in the choice of new PPIs (hip or knee prosthesis) and infer about the existence of possible response biases in using 2 alternative stated preference techniques. Methods: Six key attributes with 3 levels each were identified based on a literature review and clinical experts’ opinions. An online survey was administered to Italian hospital orthopedists using type 1 best-worst scaling (BWS) and binary discrete choice experiment (DCE). BWS data were analyzed through descriptive statistics and conditional logit model. A mixed logit regression model was applied to DCE data, and willingness-to-pay (WTP) was estimated. All analyses were conducted using Stata 16. Results: A sample of 108 orthopedists were enrolled. In BWS, the most important attribute was “clinical evidence,” followed by “quality of products,” while the least relevant items were “relationship with the sales representative” and “cost.” DCE results suggested instead that orthopedists prefer high-quality products with robust clinical evidence, positive health technology assessment recommendation and affordable cost, and for which they have a consolidated experience of use and a good relationship with the sales representative. Conclusions: The elicitation of preferences for PPIs using alternative methods can lead to different results. The BWS of type 1, which is similar to a ranking exercise, seems to be more affected by acquiescent responding and social desirability than the DCE, which introduces tradeoffs in the choice task and is likely to reveal more about true preferences. Highlights: Physician preference items (PPIs) are medical devices particularly exposed to physicians’ choice with regard to type of product and supplier. Some established techniques of collecting preferences can be affected by response biases such as acquiescent responding and social desirability. Discrete choice experiments, introducing more complex tradeoffs in the choice task, are likely to mitigate such biases and reveal true physicians’ preferences for PPIs.
- Open Access
- 1 December 2022
- Published by Pacini Editore in LO SCALPELLO-OTODI Educational
- Vol. 36 (3) , 146-151
Comparison of open reduction and internal fixation and radial head resection for treatment of Mason type 2 and 3 fractures in young and active patients: our experience
Objective. The management of Mason type II and III radial head fractures (RHF) is still a debated topic. In the past, the only treatment of choice was radial head resection (RHR) but, as surgical techniques and instrumentation have advanced, internal screw fixation (ORIF) has gained popularity. The aim of this paper is to compare in a retrospective analysis the outcomes of ORIF and RHR in these fracture patterns in young patients. Methods. A total of 37 patients (age between 20 and 60 years old) affected by Mason type 2 and 3 RHF and surgically treated were collected by means of our electronic hospital database. Sixteen patients underwent RHR, and 21 patients underwent ORIF with mini screws. Functional outcomes and scores as well as the radiographs were recorded during follow-up. Results. After 22.17 months (range 12-45) of mean follow-up, the mean DASH, UCLA and MEPS scores showed no significant differences between groups (p: 0.26; 0.21; 0.23). The VAS score was unfavorable in the ORIF group compared to the RHR group (p: 0.43) although not statistically significant. Conclusions. The gold standard in the management of these fractures is not universally recognized. The advantages and complications of both techniques as well as of the RH arthroplasty are abundantly described. Our outcomes support RHR as a possible treatment choice in multi-fragmentary fractures of RH in young patients while minimizing complications.
- 1 December 2022
- Published by Pacini Editore in LO SCALPELLO-OTODI Educational
- Vol. 36 (3) , 146-151
Open AccessComparison of open reduction and internal fixation and radial head resection for treatment of Mason type 2 and 3 fractures in young and active patients: our experience
Objective. The management of Mason type II and III radial head fractures (RHF) is still a debated topic. In the past, the only treatment of choice was radial head resection (RHR) but, as surgical techniques and instrumentation have advanced, internal screw fixation (ORIF) has gained popularity. The aim of this paper is to compare in a retrospective analysis the outcomes of ORIF and RHR in these fracture patterns in young patients. Methods. A total of 37 patients (age between 20 and 60 years old) affected by Mason type 2 and 3 RHF and surgically treated were collected by means of our electronic hospital database. Sixteen patients underwent RHR, and 21 patients underwent ORIF with mini screws. Functional outcomes and scores as well as the radiographs were recorded during follow-up. Results. After 22.17 months (range 12-45) of mean follow-up, the mean DASH, UCLA and MEPS scores showed no significant differences between groups (p: 0.26; 0.21; 0.23). The VAS score was unfavorable in the ORIF group compared to the RHR group (p: 0.43) although not statistically significant. Conclusions. The gold standard in the management of these fractures is not universally recognized. The advantages and complications of both techniques as well as of the RH arthroplasty are abundantly described. Our outcomes support RHR as a possible treatment choice in multi-fragmentary fractures of RH in young patients while minimizing complications.
- 1 October 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (2) , 407-412
Medially congruent total knee arthroplasty in valgus knee deformities yields satisfactory outcomes: a multicenter, international study
Purpose: Postoperative instability represents one of the most common complications following primary total knee arthroplasty (TKA). To prevent this outcome, valgus deformities have been historically treated using more constrained implants. The purpose of this study was to evaluate the outcome of treating a moderate valgus deformity by combining a surgical technique used to release the postero‐lateral soft tissue envelope with the use of a medially congruent (MC) TKA design without using classical, semi‐constrained inserts.Methods: Seventy‐nine MC TKAs were performed by three surgeons at three institutions between 2016 and 2018 as part of a multicenter, international study. Inclusion criteria were: radiographic late‐stage osteoarthritic knees with Ranawat’s type 1 or 2 classification of valgus deformity and integrity of the medial capsular–ligament complex (less than 10 mm of medial opening during valgus stress test at 10° of knee flexion). Exclusion criteria were: BMI > 40; neuromuscular, metabolic, or immunologic disorders; or the inability to complete outcome measures or radiographic assessment.Results: Seventy‐seven patients (79 knees), 59 males and 18 females, were evaluated at 2‐year minimum follow‐up according to the Knee Society Score (KSS) and Forgotten Joint Score (FJS). Mean age at surgery was 70 years (range 48–91). The mean range of motion (ROM) improved from 110° (range 85°–130°) preoperatively to 121° (range 105°–135°) (p < 0.001) at the time of the last follow‐up. Preoperative knee extension significantly improved from 3° (range − 15° to 20°) to 1° (range − 5° to 5°) of flexion at the last follow‐up in all the patients. KSS and KSS Functional scores were 89 (range 65–100) and 82 points (range 55–100), respectively. The FJS obtained at the last follow‐up was 72 (range 49–88). Two patients (2.5%) had major postoperative complications (one periprosthetic joint infection; one postoperative patellar fracture) requiring surgical interventions.Conclusions: In different surgeon’s hands, the use of a modern medially congruent TKA design yielded good clinical outcomes at 2 years in a consecutive series of TKA in valgus arthritic knees. Postoperative instability was not recorded in this series and this finding was related to the high conformity design of the MC polyethylene insert, which significantly differs from classical posterior‐stabilized (PS) designs.Level of evidence: IV.
- 1 October 2021
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 31 (2) , 407-412
Medially congruent total knee arthroplasty in valgus knee deformities yields satisfactory outcomes: a multicenter, international study
Purpose: Postoperative instability represents one of the most common complications following primary total knee arthroplasty (TKA). To prevent this outcome, valgus deformities have been historically treated using more constrained implants. The purpose of this study was to evaluate the outcome of treating a moderate valgus deformity by combining a surgical technique used to release the postero‐lateral soft tissue envelope with the use of a medially congruent (MC) TKA design without using classical, semi‐constrained inserts.Methods: Seventy‐nine MC TKAs were performed by three surgeons at three institutions between 2016 and 2018 as part of a multicenter, international study. Inclusion criteria were: radiographic late‐stage osteoarthritic knees with Ranawat’s type 1 or 2 classification of valgus deformity and integrity of the medial capsular–ligament complex (less than 10 mm of medial opening during valgus stress test at 10° of knee flexion). Exclusion criteria were: BMI > 40; neuromuscular, metabolic, or immunologic disorders; or the inability to complete outcome measures or radiographic assessment.Results: Seventy‐seven patients (79 knees), 59 males and 18 females, were evaluated at 2‐year minimum follow‐up according to the Knee Society Score (KSS) and Forgotten Joint Score (FJS). Mean age at surgery was 70 years (range 48–91). The mean range of motion (ROM) improved from 110° (range 85°–130°) preoperatively to 121° (range 105°–135°) (p < 0.001) at the time of the last follow‐up. Preoperative knee extension significantly improved from 3° (range − 15° to 20°) to 1° (range − 5° to 5°) of flexion at the last follow‐up in all the patients. KSS and KSS Functional scores were 89 (range 65–100) and 82 points (range 55–100), respectively. The FJS obtained at the last follow‐up was 72 (range 49–88). Two patients (2.5%) had major postoperative complications (one periprosthetic joint infection; one postoperative patellar fracture) requiring surgical interventions.Conclusions: In different surgeon’s hands, the use of a modern medially congruent TKA design yielded good clinical outcomes at 2 years in a consecutive series of TKA in valgus arthritic knees. Postoperative instability was not recorded in this series and this finding was related to the high conformity design of the MC polyethylene insert, which significantly differs from classical posterior‐stabilized (PS) designs.Level of evidence: IV.