Mohammad Reza Ghaemdoust
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mohammad Reza Ghaemdoust has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Babak Jamhiri
State Key Laboratory of Ocean Engineering, Shanghai Jiao Tong University, Shanghai, China
1 shared publicationFeiliang Wang
State Key Laboratory of Ocean Engineering, Shanghai Jiao Tong University, Shanghai, China
1 shared publication- Feiliang Wang
State Key Laboratory of Ocean Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
1 shared publication Jian Yang
State Key Laboratory of Ocean Engineering, Shanghai Jiao Tong University, Shanghai, China
1 shared publication- Jian Yang
State Key Laboratory of Ocean Engineering, Shanghai Jiao Tong University, Shanghai 200240, China
1 shared publication - Kambiz Narmashiri
Department of Civil Engineering, Zahedan Branch, Islamic Azad University, Zahedan, Iran
1 shared publication
Latest Publications
- 16 October 2023
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (16) , 3065-3088
Performance assessment of post-tensioned concrete-filled steel tube beams using unbonded tendons with uncertainty quantification
The centerpiece of many research projects is evaluating the structural performance of the concrete-filled steel tubes (CFSTs). When these structural elements are employed as flexural members, some parts of the concrete infill are subjected to tension, and consequently the concrete is cracked so that the confinement effect is reduced. Therefore, the application of tendons and modification of the CFST configuration are deployed to improve the serviceability of the CFST beams. A non-linear finite element (FE) model considering the effects of the material and geometrical non-linearity and initial imperfection is developed. Concurrently, an analytical model based on the plastic stress distribution method (PSDM) is proposed to compare the results. In addition, a probabilistic assessment along with the uncertainty quantification is conducted to calculate the reliability indices and the sensitivity of the beams to the variation of the input variables. The results of the study demonstrate that the implemented measures considerably enhance the moment capacity and serviceability performance of the CFST beams. Moreover, the sensitivity analyses show the significance of the variables on the model output with different steel yield stress values and the importance is ordered as the steel tube width followed by the steel tube thickness and the concrete strength.
- 16 October 2023
- Published by SAGE Publications in Advances in Structural Engineering
- Vol. 26 (16) , 3065-3088
Performance assessment of post-tensioned concrete-filled steel tube beams using unbonded tendons with uncertainty quantification
The centerpiece of many research projects is evaluating the structural performance of the concrete-filled steel tubes (CFSTs). When these structural elements are employed as flexural members, some parts of the concrete infill are subjected to tension, and consequently the concrete is cracked so that the confinement effect is reduced. Therefore, the application of tendons and modification of the CFST configuration are deployed to improve the serviceability of the CFST beams. A non-linear finite element (FE) model considering the effects of the material and geometrical non-linearity and initial imperfection is developed. Concurrently, an analytical model based on the plastic stress distribution method (PSDM) is proposed to compare the results. In addition, a probabilistic assessment along with the uncertainty quantification is conducted to calculate the reliability indices and the sensitivity of the beams to the variation of the input variables. The results of the study demonstrate that the implemented measures considerably enhance the moment capacity and serviceability performance of the CFST beams. Moreover, the sensitivity analyses show the significance of the variables on the model output with different steel yield stress values and the importance is ordered as the steel tube width followed by the steel tube thickness and the concrete strength.
- Open Access
Numerical Investigation on the Transverse Vibration of Prestressed Large-Span Beams with Unbonded Internal Straight Tendon
This paper deals with the effect of the prestress load on the free and forced dynamic behavior and vertical vibration of the prestressed beams. The analysis applies both the analytical frequency equation and the finite element method (FEM) using ABAQUS software to predict the fundamental natural frequency (FNF) of the simply supported unbonded prestressed beams. The energy method has been employed to derive the effective prestressing load to determine the eccentricity effect. In regard to the forced response of the prestressed beam, a moving point load with a constant value and various velocities and excitation frequencies is applied. Extensive parametric studies are carried out taking into account different factors including prestress load, eccentricity, concrete ratio, span-to-depth ratio, velocity, and frequency of the moving load. The comparison of the FNFs obtained by the formula with those obtained from FEM models indicates that the results are in a good agreement. This convergence demonstrates that the proposed formulation can predict the FNF of the eccentrically prestressed beams with high reliability. The time-histories curves for midspan displacement of the unbonded prestressed beams and the dynamic magnification factors are also evaluated. The results illustrate that the aforementioned factors have an indispensable contribution to the beam dynamic behavior.
Open AccessNumerical Investigation on the Transverse Vibration of Prestressed Large-Span Beams with Unbonded Internal Straight Tendon
This paper deals with the effect of the prestress load on the free and forced dynamic behavior and vertical vibration of the prestressed beams. The analysis applies both the analytical frequency equation and the finite element method (FEM) using ABAQUS software to predict the fundamental natural frequency (FNF) of the simply supported unbonded prestressed beams. The energy method has been employed to derive the effective prestressing load to determine the eccentricity effect. In regard to the forced response of the prestressed beam, a moving point load with a constant value and various velocities and excitation frequencies is applied. Extensive parametric studies are carried out taking into account different factors including prestress load, eccentricity, concrete ratio, span-to-depth ratio, velocity, and frequency of the moving load. The comparison of the FNFs obtained by the formula with those obtained from FEM models indicates that the results are in a good agreement. This convergence demonstrates that the proposed formulation can predict the FNF of the eccentrically prestressed beams with high reliability. The time-histories curves for midspan displacement of the unbonded prestressed beams and the dynamic magnification factors are also evaluated. The results illustrate that the aforementioned factors have an indispensable contribution to the beam dynamic behavior.
- 9 September 2019
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Civil Engineering
- Vol. 63 (3) , 908-917
Numerical and Experimental Study on Deficient Short Steel Tubes Strengthened with CFRP Under Compression
In view of development and repair costs, support of structures is imperative. Several factors, for example, design and calculation errors, absence of appropriate installation, change of structures application, exhaustion, seismic tremor, fire and natural conditions diminish their strength. In such cases, structures have need of rehabilitation and restoration to achieve their original performance. One of the most up to date materials for retrofitting is carbon fiber reinforced polymer (CFRP) that can provide an amount of restriction to postpone buckling of thin steel walls. This paper provides a numerical and experimental investigation on CFRP strengthened short steel tubes with initial horizontal and vertical deficiency under compression. Ten square and circular specimens were tested to study effects of the following parameters: (1) position of deficiency, horizontal or vertical; (2) tube shape, square or circular; (3) CFRP strengthening. In the experiments, axial static loading was gradually applied and for the numerical study three-dimensional (3D) static nonlinear analysis method using ABAQUS software was performed. The results show that deficiency reduces load-bearing capacity of steel columns and the impact of horizontal deficiency is higher than the impact of vertical deficiency, in both square and circular tubes. Use of CFRP materials for strengthening of short steel columns with initial deficiency indicates that fibers play a considerable role on increasing load bearing capacity, reducing stress at the damage location, preventing deformation caused by deficiency and delaying local buckling. Both numerical and experimental outcomes are in good agreement, which underlines the accuracy of the models adopted.
- 9 September 2019
- Published by Periodica Polytechnica Budapest University of Technology and Economics in Periodica Polytechnica Civil Engineering
- Vol. 63 (3) , 908-917
Numerical and Experimental Study on Deficient Short Steel Tubes Strengthened with CFRP Under Compression
In view of development and repair costs, support of structures is imperative. Several factors, for example, design and calculation errors, absence of appropriate installation, change of structures application, exhaustion, seismic tremor, fire and natural conditions diminish their strength. In such cases, structures have need of rehabilitation and restoration to achieve their original performance. One of the most up to date materials for retrofitting is carbon fiber reinforced polymer (CFRP) that can provide an amount of restriction to postpone buckling of thin steel walls. This paper provides a numerical and experimental investigation on CFRP strengthened short steel tubes with initial horizontal and vertical deficiency under compression. Ten square and circular specimens were tested to study effects of the following parameters: (1) position of deficiency, horizontal or vertical; (2) tube shape, square or circular; (3) CFRP strengthening. In the experiments, axial static loading was gradually applied and for the numerical study three-dimensional (3D) static nonlinear analysis method using ABAQUS software was performed. The results show that deficiency reduces load-bearing capacity of steel columns and the impact of horizontal deficiency is higher than the impact of vertical deficiency, in both square and circular tubes. Use of CFRP materials for strengthening of short steel columns with initial deficiency indicates that fibers play a considerable role on increasing load bearing capacity, reducing stress at the damage location, preventing deformation caused by deficiency and delaying local buckling. Both numerical and experimental outcomes are in good agreement, which underlines the accuracy of the models adopted.