Ted Lowenkopf
Research Subjects
Research Interests
Ted Lowenkopf has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Aaron Stayman
Swedish Medical Center, Seattle, WA (A.S., C.M.D.).
1 shared publication - Andrei V. Alexandrov
Department of Neurology, University of Arizona, Phoenix
1 shared publication - Colleen M. Douville
Swedish Medical Center, Seattle, WA (A.S., C.M.D.).
1 shared publication - Georgios Tsivgoulis
Second Department of Neurology, National and Kapodistrian University of Athens, Attikon University Hospital, Greece (G.T.).
1 shared publication - John J. Volpi
Neurology, Houston Methodist Neurological Institute, Houston, USA
1 shared publication - Mark N. Rubin
Neurology, University of Tennessee Health Science Center
1 shared publication
Latest Publications
- Open Access
- 1 November 2023
- Published by Wolters Kluwer Health in Stroke
- Vol. 54 (11) , 2842-2850
Robot-Assisted Transcranial Doppler Versus Transthoracic Echocardiography for Right to Left Shunt Detection
BACKGROUND: Right to left shunt (RLS), including patent foramen ovale, is a recognized risk factor for stroke. RLS/patent foramen ovale diagnosis is made by transthoracic echocardiography (TTE), which is insensitive, transesophageal echocardiography, which is invasive, and transcranial Doppler (TCD), which is noninvasive and accurate but scarce. METHODS: We conducted a prospective, single-arm device clinical trial of robot-assisted TCD (raTCD) versus TTE for RLS diagnosis at 6 clinical sites in patients who presented with an event suspicious for embolic cerebrovascular ischemia from October 6, 2020 to October 20, 2021. raTCD was performed with standard TCD bubble study technique. TTE bubble study was performed per local standards. The primary outcome was rate of RLS detection by raTCD versus TTE. RESULTS: A total of 154 patients were enrolled, 129 evaluable (intent to scan) and 121 subjects had complete data per protocol. In the intent to scan cohort, mean age was 60±15 years, 47% were women, and all qualifying events were diagnosed as ischemic stroke or transient ischemic attack. raTCD was positive for RLS in 82 subjects (64%) and TTE was positive in 26 (20%; absolute difference 43.4% [95% CI, 35.2%–52.0%]; P P <0.001). There were no serious adverse events. CONCLUSIONS: raTCD was safe and ≈3 times more likely to diagnose RLS than TTE. TTE completely missed or underdiagnosed two thirds of large shunts diagnosed by raTCD. The raTCD device, used by health professionals with no prior TCD training, may allow providers to achieve the known sensitivity of TCD for RLS and patent foramen ovale detection without the need for an experienced operator to perform the test. Pending confirmatory studies, TCD appears to be the superior screen for RLS compared with TTE (funded by NeuraSignal). REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04604015.
- 1 November 2023
- Published by Wolters Kluwer Health in Stroke
- Vol. 54 (11) , 2842-2850
Open AccessRobot-Assisted Transcranial Doppler Versus Transthoracic Echocardiography for Right to Left Shunt Detection
BACKGROUND: Right to left shunt (RLS), including patent foramen ovale, is a recognized risk factor for stroke. RLS/patent foramen ovale diagnosis is made by transthoracic echocardiography (TTE), which is insensitive, transesophageal echocardiography, which is invasive, and transcranial Doppler (TCD), which is noninvasive and accurate but scarce. METHODS: We conducted a prospective, single-arm device clinical trial of robot-assisted TCD (raTCD) versus TTE for RLS diagnosis at 6 clinical sites in patients who presented with an event suspicious for embolic cerebrovascular ischemia from October 6, 2020 to October 20, 2021. raTCD was performed with standard TCD bubble study technique. TTE bubble study was performed per local standards. The primary outcome was rate of RLS detection by raTCD versus TTE. RESULTS: A total of 154 patients were enrolled, 129 evaluable (intent to scan) and 121 subjects had complete data per protocol. In the intent to scan cohort, mean age was 60±15 years, 47% were women, and all qualifying events were diagnosed as ischemic stroke or transient ischemic attack. raTCD was positive for RLS in 82 subjects (64%) and TTE was positive in 26 (20%; absolute difference 43.4% [95% CI, 35.2%–52.0%]; P P <0.001). There were no serious adverse events. CONCLUSIONS: raTCD was safe and ≈3 times more likely to diagnose RLS than TTE. TTE completely missed or underdiagnosed two thirds of large shunts diagnosed by raTCD. The raTCD device, used by health professionals with no prior TCD training, may allow providers to achieve the known sensitivity of TCD for RLS and patent foramen ovale detection without the need for an experienced operator to perform the test. Pending confirmatory studies, TCD appears to be the superior screen for RLS compared with TTE (funded by NeuraSignal). REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04604015.