Junyan Xiao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Junyan Xiao has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Evan Bentz
Department of Civil & Mineral Engineering University of Toronto Toronto Canada
1 shared publication- Jae-Wook Jung
Advanced Structures and Seismic Safety Research Division, Korea Atomic Energy Research Institute, Daejeon 34057, Republic of Korea
1 shared publication Minkyu Kim
Advanced Structures and Seismic Safety Research Division, Korea Atomic Energy Research Institute Daejeon Republic of Korea
1 shared publication- Oh-Sung Kwon
University of Toronto
1 shared publication
Latest Publications
- 16 October 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (1) , 414-431
Effect of modeling assumptions on predicting seismic responses of a three‐story reinforced concrete shear wall structure
The behavior of short‐period reinforced concrete (RC) shear wall structures is often complicated and hard to predict accurately, even when the structure behaves in the elastic region, due to significant uncertainties in the material and the environment. Modeling assumptions used in finite element (FE) analyses often influence the accuracy of the dynamic response predictions. This paper discusses the numerical modeling of shaking table tests of a 3‐story RC shear wall specimen, which was carried out by Korea Atomic Energy Research Institute in July 2020. The experimental program is briefly introduced in this paper. Through nonlinear time history analyses using ABAQUS, the effect of modeling assumptions on the accuracy of the FE methods in predicting the linear and moderately nonlinear behavior of the RC structure is presented. Two commonly used modeling/model updating assumptions are considered: concrete Young's modulus and foundation flexibility. Influences of such modeling assumptions in predicting beyond design dynamic behavior (i.e., nonlinear responses and damage development) of the testing structure are also studied. The results showed that the accuracy of the dynamic response prediction of the structure could be improved significantly after calibrating the models against the white noise test results. Nevertheless, models established with different modeling assumptions can only capture the behavior of the structure at certain seismic intensity levels. Different models give results with a considerable variation in the structure's peak acceleration, floor response spectrum, acceleration amplification profile, damage pattern, and damage severity.
- 16 October 2023
- Published by Wiley in Earthquake Engineering & Structural Dynamics
- Vol. 53 (1) , 414-431
Effect of modeling assumptions on predicting seismic responses of a three‐story reinforced concrete shear wall structure
The behavior of short‐period reinforced concrete (RC) shear wall structures is often complicated and hard to predict accurately, even when the structure behaves in the elastic region, due to significant uncertainties in the material and the environment. Modeling assumptions used in finite element (FE) analyses often influence the accuracy of the dynamic response predictions. This paper discusses the numerical modeling of shaking table tests of a 3‐story RC shear wall specimen, which was carried out by Korea Atomic Energy Research Institute in July 2020. The experimental program is briefly introduced in this paper. Through nonlinear time history analyses using ABAQUS, the effect of modeling assumptions on the accuracy of the FE methods in predicting the linear and moderately nonlinear behavior of the RC structure is presented. Two commonly used modeling/model updating assumptions are considered: concrete Young's modulus and foundation flexibility. Influences of such modeling assumptions in predicting beyond design dynamic behavior (i.e., nonlinear responses and damage development) of the testing structure are also studied. The results showed that the accuracy of the dynamic response prediction of the structure could be improved significantly after calibrating the models against the white noise test results. Nevertheless, models established with different modeling assumptions can only capture the behavior of the structure at certain seismic intensity levels. Different models give results with a considerable variation in the structure's peak acceleration, floor response spectrum, acceleration amplification profile, damage pattern, and damage severity.